PDF-Download (4.8 MB)

www.osram.com
12/14 OSRAM does not accept liability for errors, changes and omissions.
www.osram.com
Light is essential
OSRAM ITOS® modules for medical
examination and surgical luminaires
OSRAM GmbH
Head office:
Display/Optic:
Marcel-Breuer-Strasse 6
Nonnendammallee 44
80807 Munich, Germany
13625 Berlin
Phone +49 89-6213-0
Germany
Fax
E-mail: [email protected]
+49 89-6213-2020
www.osram.com
Summary and system comparison
Light is OSRAM
OSRAM ITOS ® LED modules
OSRAM ITOS ® LED modules
OSRAM ITOS ® LED modules summary and comparison of key values
Product
ITOS ® ME
ITOS ® ME
ITOS ® ME PLUS F
ITOS ® ME PLUS FZ
ITOS ® SL
ITOS ® SL ID
Driver
ITOS ® ME Driver
ITOS ® ME PLUS Driver
ITOS ® ME PLUS Driver
ITOS ® ME PLUS Driver
ITOS ® SL Driver
ITOS ® SL Driver
Application
Examination Lights
Examination Lights
Examination Lights &
Surgical Lights
Examination Lights &
Surgical Lights
Surgical Lights
Surgical Lights
(enhanced illumination depth)
Class [klx]
up to 70 klx
up to 100 klx
~ 120 klx
~ 120 klx
max. 160 klx
max. 160 klx
System values
Reflector diameter
Optical system height
Zoom
Zoom range (D10 typical)
270 - 420 mm
130 - 180 mm
no
-
270 - 420 mm
130 - 180 mm
no
-
350 - 650 mm
120 - 150 mm
no
-
450 - 650 mm
120 - 160 mm
yes
160 - 280 mm
500 - 700 mm
200 mm
yes
175 - 295 mm
500 - 700 mm
200 mm
no zoom required
(ID 60% > 800 mm)
Meachanics
Module height
Upper module diameter
Module base dimension
Driver size
Cable (driver to module)
Module weight
Weight for bas plate/heatsink
76.9 mm
97.2 mm
100 x 100 mm²
Ø 80 mm
300 mm, included
190 g
200 - 300 g
76.9 mm
97.2 mm
100 x 100 mm²
110 x 75 mm²
300 mm, included
190 g
200 - 300 g
99 mm
140 mm
100 x 100 mm²
110 x 75 mm²
300 mm, included
205 g
200 - 650 g
99 mm
140 mm
100 x 100 mm²
110 x 75 mm²
300 mm, included
205 g
200 - 650 g
205 mm
180 mm
106 x 106 mm²
145 x 75 mm²
not included
1070 g
300 - 800 g
205 mm
180 mm
106 x 106 mm²
145 x 75 mm²
not included
1000 g
300 - 800 g
24 V
22 - 28 V
required
4 x 520 mA
-
24 V
22 - 28 V
required
4 x 650 mA
max. 650 mA
24 V
22 - 28 V
required
4 x 800 mA
500 … 800 mA
24 V
22 - 28 V
required
4 x 800 mA
500 … 800 mA
24 V
22 - 28 V
required
7 x 550 mA
300 … 550 mA
24 V
22 - 28 V
required
7 x 550 mA
300 … 550 mA
35 W
30 W
4 independent strings
buttons on driver
4 fix
PWM
45 W
38 W
4 independent strings
serial / UART interface
4 fix serial /
user defined via UART
constant current dimming
55 W
45 W
4 independent strings
serial / UART interface
4 fix serial /
user defined via UART
constant current dimming
55 W
45 W
4 independent strings
serial / UART interface
4 fix serial /
user defined via UART
constant current dimming
120 W
90 W
7 independent strings
serial / UART interface
4 fix serial /
user defined via UART
constant current dimming
120 W
90 W
7 independent strings
serial / UART interface
4 fix serial /
user defined via UART
constant current dimming
750 lm
4500 K (4200 - 4800)
Ra=95
≥90
900 lm
4500 K (4200 - 4800)
Ra=95
≥90
1250 lm
4500 K (4200 - 4800)
Ra=95
≥90
1250 lm
4400 K (4100 - 4700)
Ra=95
≥90
2650 lm
4500 K (4200 - 4800)
Ra=95
≥90
2650 lm
4500 K (4200 - 4800)
Ra=95
≥90
55 - 80 klx
175 mm
0.53
-
60 - 100 klx
175 mm
0.53
-
110 - 140 klx
175 mm
0.53
> 58 %
> 45 %
98 %
> 58 %
> 43 %
110 - 140 klx
140 - 170 mm
≥0.52
> 58 %
> 45 %
98 %
> 58 %
> 43 %
> 160 klx
175 - 220 mm
≥0.52
> 58 %
> 45 %
98 %
> 58 %
> 43 %
> 160 klx
175 - 220 mm
≥0.52
> 58 %
> 45 %
98%
> 58 %
> 43 %
> 250 mm
> 250 mm
> 500 mm
> 250 mm
> 250 mm
> 500 mm
200 - 300 mm
200 - 400 mm
400 - 600 mm
200 - 300 mm
200 - 400 mm
400 - 600 mm
> 250 mm
> 250 mm
> 500 mm
> 350 mm
> 450 mm
> 800 mm
yes
40° C
yes
yes
yes
yes
40° C
yes
yes
yes
yes
40°C
yes
yes
yes
yes
40°C
yes
yes
yes
yes
40°C
yes
yes
yes
yes
40°C
yes
yes
yes
Electrical values
Input voltage nominal
Input voltage range
SELV regulated power supply
Max. current output
Individual max. current setting
Max. system power
consumption
Nominal power consumption
Redundancy
Control
Dimming steps
Dimming technology
Optical values
Flux of module [lm]
CCT [K]
CRI typ.1)
R9 typ.1)
Optical system performance2)
EC
D10
D50/D10
1 Shutter
2 Shutter
Tube
1 Shutter + tube
2 Shutter + tube
Illumination depth at 60% EC
— L1
— L2
— ID
Others
Overheat control
Max. ambient temperature3)
CE conformity
Lifetime Indication
Failure Control system
1) At standard operating temperature
2) Values are typical for reference projects, may significantly vary for different reflector designs.
3) Values for OSRAM Reference Fixture Design with simple cooling solution