Datasheet

UNISONIC TECHNOLOGIES CO., LTD
UR132
LINEAR INTEGRATED CIRCUIT
200mA LOW DROPOUT LINEAR
VOLTAGE REGULATOR
„
DESCRIPTION
The UTC UR132 is a 200mA fixed output voltage low dropout
linear regulator. Wide range of available output voltage fits most of
applications. Built-in output current-limiting most thermal-limiting
provide maximal protection against any fault conditions.
„
FEATURES
* Guaranteed 200mA output current
* Input voltage range up to 12V
* Extremely tight load regulation
* Fast transient response
* Current-limiting and thermal-limiting
* Three-terminal adjustable or fixed voltage.
„
ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
UR132L-xx-AE3-3-R
UR132G-xx-AE3-3-R
UR132L-xx-AE3-5-R
UR132G-xx-AE3-5-R
UR132L-xx-AF5-C-R
UR132G-xx-AF5-C-R
Note: Pin assignment: I:VIN O:VOUT G:GND N: No Connection
xx: output voltage, refer to Marking Information
www.unisonic.com.tw
Copyright © 2011 Unisonic Technologies Co., Ltd
Package
SOT-23
SOT-23
SOT-25
1
O
G
I
Pin Assignment.
2
3
4
5
G
I
O
I
G N N O
Packing
Tape Reel
Tape Reel
Tape Reel
1 of 4
QW-R102-007,J
UR132
„
LINEAR INTEGRATED CIRCUIT
MARKING INFORMATION
PACKAGE
VOLTAGE CODE
12: 1.2V
15 : 1.5V
18: 1.8V
22: 2.2V
2E: 2.5V
26: 2.6V
27: 2.7V
28: 2.8V
30: 3.0V
33: 3.3V
50: 5.0V
AD: ADJ
SOT-23
SOT-25
Pin Assignment
OGI
GOI
MARKING
Voltage Code
Voltage Code
L: Lead Free
G: Halogen Free
RXX5
L: Lead Free
G: Halogen Free
5
IGNNO
4
RXX
Voltage Code
1
„
RXX
2
L: Lead Free
G: Halogen Free
3
BLOCK DIAGRAM
VIN
+
VREF
+
Current Amp
-
1.25V
Themal Limit
Current Limit
VOUT
For
Fixed
Voltage
Device
ADJ
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
GND
2 of 4
QW-R102-007,J
UR132
„
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATING
UNIT
Input Voltage
VIN
-0.3~12
V
Power Dissipation
PD
300
mW
Junction Temperature
TJ
+125
°C
Operation Temperature
TOPR
-40~+85
°C
Storage Temperature
TSTG
-40~+150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
„
ELECTRICAL CHARACTERISTICS (Ta=25°C, CIN=1μF, COUT=10μF, unless otherwise specified)
FOR VOUT<3.3V (VOUT±2%)
PARAMETER
Output Voltage
Output Voltage Temperature Coefficient
Line Regulation
Load Regulation (Note 2)
Current Limit (Note 3)
Dropout Voltage (Note 4,5)
Standby current
SYMBOL
TEST CONDITIONS
VOUT IL=2mA, VIN-VOUT=2V
TCVO
IL=2mA,
△VOUT
VIN-VOUT=2V~VIN=9V
IL=2mA~200mA,
△VOUT
VIN-VOUT =2V
IL
VIN-VOUT=2V, VOUT=0V
VD
ISTN-BY IL=0, VIN=9V
MIN
VOUT×0.98
TYP
MAX
UNIT
VOUT VOUT×1.02
V
50
150
ppm/°C
10
0.5
%VOUT
30
mV
1.5
3.0
mA
V
mA
300
FOR ADJ and VOUT≥3.3V (VOUT±2%)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Output Voltage
VOUT IL=2mA, VIN-VOUT=2V
VOUT×0.98 VOUT VOUT×1.02
V
ADJUSTABLE (R1=120Ω,R2=200Ω,VOUT=3.3V)
Reference Voltage
VREF VIN-VOUT=2V, IL=2mA
1.238
1.250
1.262
V
Output Voltage Temperature Coefficient
TCVO
50
150
ppm/°C
IL=2mA,
0.5
%VOUT
Line Regulation
△VOUT
VIN-VOUT=2V~VIN=12V
IL=2mA~200mA,
10
30
mV
Load Regulation (Note 2)
△VOUT
VIN-VOUT=2V
Current Limit (Note 3)
IL
VIN-VOUT=2V, VOUT=0V
300
mA
Dropout Voltage (Note 4,5)
VD
1.3
V
Standby current
ISTN-BY IL=0, VIN=12V
5.0
mA
Note: 1. Guaranteed by design.
2. Regulation is measured at constant junction temperature, using pulsed on time.
3. Current limit is measured at constant junction temperature, using pulsed on time.
4. Dropout is measured at constant junction temperature, using pulsed on time, and the criterion is VOUT inside
target value±2%.
5. Dropout test is skipped at the condition of VIN<3V.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 4
QW-R102-007,J
UR132
„
LINEAR INTEGRATED CIRCUIT
TYPICAL APPLICATION CIRCUIT
The part may oscillate without the capacitor, a 10μF (or larger) capacitor is recommended between VOUT and
GND for stability. Any type of capacitor can be used, but not Aluminum electrolytic when operating below -20°C. The
capacitance may be increased without limit. Besides, another 1μF capacitor (or larger) should be placed between VIN
to GND.
„
UR132 ADJUSTABLE
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
4 of 4