TE30 DS

TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
Features

Meets DoE Efficiency Level VI Requirements











No load input power
Average Efficiency
Up to 30W of AC-DC Power
Universal Input 90-264Vac Input Range
Desktop and Wall-Plug versions
Meets “Heavy Industrial” Levels of EN61000 EMC
Requirements
Meets EN55011/CISPR11, and FCC Part 15.109
Class B Conducted & Radiated Emissions, with 6db
margin
nd
Approved to EN/IEC/UL60950-1, 2 Ed., Am. 2
E-cap life of >8 years
>1,000,000 hours MTBF
3 Year Warranty
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE30A
Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, PLUS Heavy Industrial levels of various
EN61000-4-x standards for EMC.
Model Selection
Model
Number
TE30A0503F01
TE30A1203F01
TE30A1503F01
TE30A1803F01
TE30A2403F01
TE30A4803F01
TE30A0503N01
TE30A1203N01
TE30A1503N01
TE30A1803N01
TE30A2403N01
TE30A4803N01
TE30A0503Q01
TE30A1203Q01
TE30A1503Q01
TE30A1803Q01
TE30A2403Q01
TE30A4803Q01
TE30A0503B01
TE30A1203B01
TE30A1503B01
TE30A1803B01
TE30A2403B01
TE30A4803B01
TE30A0503C01
TE30A1203C01
TE30A1503C01
TE30A1803C01
TE30A2403C01
TE30A4803C01
Notes:
Volts
5.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
12.0V
15.0V
18.0V
24.0V
48.0V
Output
Current
4.00A
2.50A
2.00A
1.67A
1.33A
0.63A
4.00A
2.50A
2.00A
1.67A
1.33A
0.63A
4.00A
2.50A
2.00A
1.67A
1.33A
0.63A
4.00A
2.50A
2.00A
1.67A
1.33A
0.63A
4.00A
2.50A
2.00A
1.67A
1.33A
0.63A
Output
Power
20W
30W
30W
30W
30W
30W
20W
30W
30W
30W
30W
30W
20W
30W
30W
30W
30W
30W
20W
30W
30W
30W
30W
30W
20W
30W
30W
30W
30W
30W
Ripple &
Noise¹
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
Line
Regulation
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Overvoltage
Trip Range
5.75V-7.75V
14.4V-16.8V
18.0V-21.0V
21.6V-25.2V
28.8V-33.6V
55.0V-60.0V
5.75V-7.75V
14.4V-16.8V
18.0V-21.0V
21.6V-25.2V
28.8V-33.6V
55.0V-60.0V
5.75V-7.75V
14.4V-16.8V
18.0V-21.0V
21.6V-25.2V
28.8V-33.6V
55.0V-60.0V
5.75V-7.75V
14.4V-16.8V
18.0V-21.0V
21.6V-25.2V
28.8V-33.6V
55.0V-60.0V
5.75V-7.75V
14.4V-16.8V
18.0V-21.0V
21.6V-25.2V
28.8V-33.6V
55.0V-60.0V
Output
Connector
Input
Configuration
2.5 x 5.5 x
9.5mm
Straight Barrel
Type, center
positive
Class I
Desktop,
IEC60320 C14
Receptacle
2.5 x 5.5 x
9.5mm
Straight Barrel
Type, center
positive
Class II
Desktop,
IEC60320 C8
Receptacle
2.5 x 5.5 x
9.5mm
Straight Barrel
Type, center
positive
Class II
Desktop,
IEC60320 C18
Receptacle
2.5 x 5.5 x
9.5mm
Straight Barrel
Type, center
positive
2.5 x 5.5 x
9.5mm
Straight Barrel
Type, center
positive
Class II WallPlug,
Interchangeabl
e Blades (North
American Blade
included)²
Class II WallPlug, Fixed
North American
Blades³
1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed
are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point.
2. Order blade kit KT-1027K for other blades (EU. UK, Australia)
3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”.
4. All specifications are typical at nominal input, full load, at 25C ambient unless noted.
5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE30B1203F01).
www.slpower.com
TE30 Rev 1.7
2-MAY-16
1
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuse
Earth Leakage
Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 700mS @115Vac, full load
115Vac: 1.2A, 230Vac: 0.6A
Hold-up Time
20mS min., at full Load, 100Vac input
264Vac, cold start: will not exceed 40A
Overload Protection
2.0A, 250Vac
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
20 to 30W continuous – See models chart for
specific voltage model ratings.
No Load Input
Power
<0.1W per DoE Efficiency Level VI
Requirements
Output Voltage
Transient
Response
Regulation
Drop Test
Vibration
Dimensions
Weight
Short Circuit
Protection
Overvoltage
Protection
Meets US DoE Efficiency Level VI Average
efficiency levels
Output Power
Ripple and Noise
Overtemperature
Protection
See models chart on pg 1.
See models chart on pg 1.
500µs response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Isolation
130 to 180% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
Hiccup Mode. See model chart above for
trip ranges.
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
Safety Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Operating
Temperature
-20°C to +70°C
Start Up at -40°C, full load, (warmup period before
Temperature
Derating
See Derating Charts below.
Storage Temperature
Altitude
See models chart on pg 1.
1.4m from table top to wooden platform, 4
faces.
Will shutdown upon an overtemperature
condition, auto-recovery.
Relative Humidity
all parameters are within published specifications).
-40°C to +85°C
Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
See outline drawings
MTBF
>1,000,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
E-Cap Life
250g
>8 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day.
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE30 Rev 1.7
2-MAY-16
2
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions:
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions:
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise:
High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur
radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
Output Power Derating
Output power is derated above 40°C as follows, for operation over the entire AC input range (90-264Vac).
35
Output Power - Watts
30
25
20
5V
15
12V-48V
10
5
0
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
Ambient Temperature ͦC
www.slpower.com
TE30 Rev 1.7
2-MAY-16
3
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
Mechanical Drawing
54
33.6
1450±50
1450±50
96
95.5
55
IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector
Notes:
Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector
1. All dimensions in mm.
2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K.
3. Cable length for 5V models is 1200 +/- 50mm.
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
www.slpower.com
TE30 Rev 1.7
2-MAY-16
4
TE30
20W-30W Single Output External Power
Test & Measurement/Industrial Series
Efficiency Level VI Information:
TE30A Series
Data Sheet © 2015 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE30 Rev 1.7
2-MAY-16
5