Amendment to Test Report

Test Report issued under the responsibility of
www.nemko.com
Amendment to Test Report
This Amendment is valid only together with the main Test Report
Report No . ..................................... : 271889
Main Report No . ............................ : 257636
Date of issue ................................. : Nov. 10, 2014
Total number of pages ................. : 10 pages and refer to page 3
Applicant's Name .......................... : ON Semiconductor
Address ......................................... : 5005 East McDowell Rd, Phoenix, AZ, 85008, U.S.A.
Test specification
Standard ......................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Test procedure .............................. : CB scheme
Non-standard test method ........... : N/A
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright
owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's
interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description ................... : AC/DC Controller
Trade Mark ..................................... :
Manufacturer ................................. : Same as applicant
Model/Type reference ................... : 1) NCP1244; NCP1246; NCP1247; NCP1248; NCP1240;
SCY99126; SCY99157; SCY99194; DAP041; SCY99146; DAP028;
2) SCY99158; DAP027; NCP1615
Ratings............................................ : 1) HV pin: 11mA / 500 VDC , VCC pin: 28V
2) HV pin: 700 VDC , VCC pin: 28V
(Applicable for use to mains supply 100-240Vac 60-50Hz)
Nemko Rev. 2013-10
This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by
a laboratory having special agreement with Nemko.
Page 2 of 10
Report No. 271889
Testing procedure and testing location:
CB Testing Laboratory:
Testing location/ address ....................... :
Nemko Taiwan
5 Fl., No. 409, Sec.2, Tiding Blvd., Neihu, Taipei 114, Taiwan
Associated CB Laboratory:
Testing location/ address ....................... :
Tested by (name + signature) ....... :
Jason Chu
Approved by (name + signature) .. :
Roger Liou
Testing procedure: TMP
Testing location/ address ....................... :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Testing procedure: WMT
Testing location/ address ....................... :
Tested by (name + signature) ....... :
Witnessed by (name + signature) :
Approved by (name + signature) .. :
Testing procedure: SMT
Testing location/ address ....................... :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Supervised by (name + signature) :
Testing procedure: RMT
Testing location/ address ....................... :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Supervised by (name + signature) :
Page 3 of 10
Report No. 271889
Summary of testing:
Tests performed (name of test and test clause):
2.1 Protection from electric shock and
energy hazards
2.9 Electrical insulation
Test based on CTL decision sheet, DSH 1080
Testing location:
See page 2
Operation condition:
Normal Load:
The IC was connected to 110% of rated input voltage
based on CTL decision sheet, DSH 1080.
Summary of compliance with National Differences
The sample(s) tested compliance with the requirements of IEC 60950-1: 2005 (2nd Edition); Am1: 2009;
Am2: 2013 and all CENELEC members as listed in EN 60950-1: 2006 +A11: 2009+A1: 2010 + A12:2011
+ A2: 2013.
At the time of issuing this test report, not all countries are listed for IEC 60950-1:2005 (2nd Edition); Am1:
2009+Am2:2013. Therefore the main test report includes national differences for IEC 60950-1: 2001 1st
Edition and IEC 60950-1: 2005 2ed Edition.
All national differences listed in the IECEE Online CB Bulletin are covered by the Common
Modifications,Special National Conditions, National Deviations, and the National Requirements noted
above except for the countries which are documented in main test report.
“The update concern is not effecting to national difference which listed in main test report.”
List of Attachments (including a total number of pages in each attachment):
1. Photos (1 page)
2. Unit datasheet (83 pages)
Page 4 of 10
Report No. 271889
Copy of marking plate:
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
The following marking is located on IC carton that are the same except model name, list one model to
represent others.
The following marking is located on IC body. Due to letter limited, only part code name located in the
IC body, for example as below.
SCY99194, DAP041:
SCY99146:
SCY99158, DAP027:
NCP1615:
DAP028:
Page 5 of 10
Report No. 271889
Possible test case verdicts:
- test case does not apply to the test object ........... : Not Applicable (N/A)
- test object does meet the requirement.................. : Pass (P)
- test object does not meet the requirement ........... : Fail (F)
Testing.......................................................................... :
Date of receipt of test item ........................................ : Oct., 2014
Date(s) of performance of tests ................................ : Oct. to Nov., 2014
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ................................................. :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... :
ON Semiconductor
5005 East McDowell Rd, Phoenix, AZ, 85008, U.S.A.
Page 6 of 10
Report No. 271889
General product information:
This Amendment shall always be enclosed with main Test Report, report/order no: 257636.
The changes concern the following:
- Correct Test item description from AC/DC Flyback Controller to AC/DC Controller.
- Evaluate of adding resistor with the smallest resistance (1kΩ) or the resistor with the largest resistance
(10kΩ) in the ICX.
- Add seven models SCY99194, DAP041, SCY99146, DAP028, SCY99158, DAP027 and NCP1615 which
are identical to original ones except different model name and the models SCY99158, DAP027, NCP1615
are with PFC function.
Requirements:
The ICX and it associated components critical to the discharge function of a capacitor to an accessible part
(such as the mains capacitor) are not fault tested if the following condition is met:
The ICX with the associated circuitry as provided in the equipment complies with the tests below. Any
impulse attenuating components (such as varistors and GDT’s) that attenuate the impulse to the ICX and
the associated circuitry are disconnected.
If discharge components external to the ICX are necessary, they shall not fail during the tests
Tests:
Where the ICX is tested by itself, the test set up shall be as recommended by the ICX manufacturer.
- humidity treatment for 120 hrs at a temperature of (85±2, based on client request)°C and a relative
humidity of (93±3)%.
- 100 positive impulses and 100 negative impulses between line and neutral using a capacitor with the
largest capacitance and a resistor with the smallest resistance specified by the manufacturer of the ICX;
and repeated with a capacitor with the smallest capacitance and the resistor with the largest resistance.
The time between any two impulses shall not be less than 1 s. The impulse shall be as specified in circuit
2 of Table N.1 (60950-1) / 1.2/50 μs with Uc equal to the transient voltage.
- Application of an a.c. voltage that is 110 % of the rated voltage for 2.5 minutes.
- 10 000 cycles of power on and off using a capacitor with the smallest capacitance and a resistor with the
largest resistance as specified by the manufacturer of ICX. The power on and off cycles time shall not be
less than 1 s.
All tests were conducted with model NCP1244 and NCP1615 for represent others, if nothing else
mentioned.
Project history:
Nemko Report/ Modification to the appliances:
Order No.:
257636
271889
Main test report.
- Correct Test item description from AC/DC Flyback Controller to
AC/DC Controller.
- Evaluate of adding resistor with the smallest resistance (1kΩ) or
the resistor with the largest resistance (10kΩ) in the ICX.
- Add seven models SCY99194, DAP041, SCY99146, DAP028,
SCY99158, DAP027 and NCP1615 which are identical to original
ones except different model name and the models SCY99158,
DAP027, NCP1615 are with PFC function.
Changes/
Modifications in
clause(s):
-1.5, 1.7, 2.1 and 2.9
Page 7 of 10
Report No. 271889
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.5
Components
1.5.1
General
See below.
P
Comply with IEC 60950-1 or relevant component
standard
(see appended table 1.5.1)
P
P
1.7
Marking and instructions
1.7.1
Power rating and identification markings
Refer to copy of marking plate.
P
1.7.1.1
Power rating marking
See below.
P
Multiple mains supply connections.........................:
The equipment is an integrated
circuit (IC) including a capacitor
discharge function for buildingin, must be considered when
installed in the end product.
—
Rated voltage(s) or voltage range(s) (V) .............. :
The equipment is an integrated
circuit (IC) without the marking
of rated voltage, it must be
considered in end of product.
—
Symbol for nature of supply, for d.c. only .............. :
The equipment is for a.c.
supply.
Rated frequency or rated frequency range (Hz) ... :
The equipment is an integrated
circuit (IC) without the marking
of rated frequency range, it
must be considered in end of
product.
—
Rated current (mA or A) ........................................ :
The equipment is an integrated
circuit (IC) without the marking
of rated frequency range, it
must be considered in end of
product.
—
Identification markings
Refer to below:
P
1.7.1.2
2.1
P
N/A
Manufacturer’s name or trade-mark or identification See page 1
mark ...................................................................... :
—
Model identification or type reference ................... :
See copy of marking plate for
details.
—
Symbol for Class II equipment only ...................... :
The equipment is an integrated
circuit (IC) including a capacitor
discharge function for buildingin, must be considered when
installed in the end product.
—
Other markings and symbols ................................ :
The additional marking does
not give rise to
misunderstandings.
P
Protection from electric shock and energy hazards
P
Page 8 of 10
Report No. 271889
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.1.1.7
Discharge of capacitors in equipment
The measurements were
performed after treameant of
humidity based on CTL
decision sheet, DSH 1080 and
following conditions.
P
Measured voltage (V); time-constant (s)................ :
- humidity treament for 120h at
temperature of 42°C and a
relative humidity of 95%, then
- 100 positive impulses and 100
negative impulses between line
and neutral with Uc=2500V
using a capacitor with the
largest capacitance (4.7μF)
and a resistor with the smallest
resistance (1kΩ) specified by
the manufacturer of the ICX;
and repeated with a capacitor
with the smallest capacitance
(0.001μF) and the resistor with
the largest resistance (10kΩ),
then
- Application of an a.c. voltage
264V (110% of the rated
voltage) for 2.5 minutes, then
- 10000 cycles of power on and
off using a capacitor with the
smallest capacitance (0.001μF)
and and a resistor with the
largest resistance (10kΩ) as
specified by the manufacturer
of ICX.
- Condition is: no load, and with
following conditions:
Model NCP1244:
1. Time constant were
measured to: (measured 390
Vpeak, 37% Vpeak= 144.3V,
total capacitance= 4.7μF,
resistance= 1kΩ)
For set 1: 252 ms ;
For set 2: 252 ms;
For set 3: 250 ms.
2. Time constant were
measured to: (measured 372
Vpeak, 37% Vpeak= 137.6V,
total capacitance= 0.001μF,
resistance= 10kΩ)
For set 1: 5.8 ms ;
For set 2: 7.0 ms;
For set 3: 8.4 ms.
—
Page 9 of 10
Report No. 271889
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Measured voltage (V); time-constant (s)................ :
Model NCP1615:
1. Time constant were
measured to: (measured 372
Vpeak, 37% Vpeak= 137.6V,
total capacitance= 4.7μF,
resistance= 1kΩ)
For set 1: 105 ms ;
For set 2: 104 ms;
For set 3: 105 ms.
2. Time constant were
measured to: (measured 376
Vpeak, 37% Vpeak= 139.1V,
total capacitance= 0.001μF,
resistance= 10kΩ)
For set 1: 13.6 ms ;
For set 2: 12.6 ms;
For set 3: 13.6 ms.
Verdict
—
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
Neither natural rubber,
materials containing asbestos
nor hygroscopic materials are
used as insulation. No driving
belts or couplings used.
N/A
2.9.2
Humidity conditioning
Humidity treatment performed
for 120hrs.
P
Relative humidity (%), temperature (°C) ...............: 95%, 42°C.
—
2.9.3
Grade of insulation
The equipment is an integrated
circuit (IC) including a capacitor
discharge function for buildingin, must be considered when
installed in the end product.
—
2.9.4
Separation from hazardous voltages
The equipment is an integrated
circuit (IC) including a capacitor
discharge function for buildingin, must be considered when
installed in the end product.
—
Method(s) used .....................................................:
—
Page 10 of 10
1.5.1
TABLE: List of critical components
Object/part No.
Resistors
Report No. 271889
Manufacturer/
trademark
Type/model
Interchangeabl
e
Interchangeabl
e
P
Technical data
1/4W, total
resistance:
1kΩ - 10kΩ
Standard
(Edition / year)
--
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-2039.
Mark(s) of
conformity1)
Tested in the
equipment