Series 36 RAST 5 connectors 3623 · 3625 · 3626 · 3628 3625-1 - 3628-1 3611 · 3615 3633 3636 3612 · 3613 · 3614 3641–3645 3649 3671 · 3672 · 3673 · 3674 3676 · 3677 · 3678 · 3679 3686 · 3687 3680 · 3683 3647 · 3648 3647-1 3618 3602 RAST 5 connectors for indirect mating, insulation displacement technology RAST 5 connectors for indirect mating, insulation displacement technology, for use in a higher temperature range RAST 5 connectors for indirect mating, with screw terminals RAST 5 connectors for direct mating, insulation displacement technology RAST 5 connectors for direct mating, insulation displacement technology, with or without keying rib and closed sides RAST 5 connectors for direct mating, with screw terminals RAST 5 tab header Dual row RAST 5 tab header Free-to-configure system of tab headers, with or without separations Free-to-configure system of tab headers, with or without separations as well as neutral and protective conductor bridge in insulation displacement technology Free-to-configure system of socket boards, with or without separations as well as neutral and protective conductor bridge in insulation displacement technology Free-to-configure system of combined tab headers and socket boards, with or without separations as well as neutral and protective conductor bridge in insulation displacement technology RAST 5 tab header, insulation displacement technology RAST 5 tab header, insulation displacement technology, for use in a higher temperature range RAST 5 tab header, with screw terminals RAST 5 guide frame pitch 5.0 mm (0.197") with exterior locking 3623, 3625 (362... 01 locking on tab) with exterior locking 3625-1 with interior locking 3611 straight cable exit 3615 angular cable exit, opposite to locking (3615-1 with handle latch) 3615-2 angular cable exit, on side of locking (3615-3 with handle latch) with exterior locking by means of guide frame with or without locking on printed circuit board 3612 with interior locking 3613 with or without keying rib and closed sides 3614 alternatively with or without keying rib and (shorter) closed sides upright 3641 with spigot angular 3642 topside lock 3643 lower side lock 3644 lower side lock, higher version, with spigot 3645 lower side lock, higher version angular 3649 with lower side lock upright 3671 with spigot angular 3672 topside lock 3673 lower side lock 3674 lower side lock, higher version, with spigot upright 3676 with spigot angular 3677 topside lock 3678 lower side lock 3679 lower side lock, higher version, with spigot 3686 upright 3687 angular 3680 upright 3683 angular 3647 without locking latches 3648 with locking latches for chassis mounting 3647-1 without locking latches 3618 cable exit opposite to locking (3618-1 with handle latch) 3618-2 cable exit on side of locking (3618-3 with handle latch) 361899 with pre-mating protective contacts 3602 guide frame for use with connectors 3612, 3633 mating with connectors 3611, 3615, 362... mating with connectors 3611, 3615, 362... mating with connectors 3611, 3615, 3623, 3626 mating with connectors 3618, 3647 mating tab headers with connectors 3611, 3615, 3623, 2626 and socket boards with connectors 3618, 3647 mating with connectors 3611, 3615, 362..., 368... mating with connectors 3625-1 and 3628-1 mating with connectors 3611, 3615, 3623, 3626, 368... Direct and indirect mating, for cable-to-board and cable-to-cable connections with insulation displacement or screw clamp termination. Keying according to RAST 5 standard avoids mismating. with interior locking 3626, 3628 (3628 chassis connector) with interior locking 3628-1 chassis connector 367...99 with pre-mating protective contacts For signal and load currents up to 16 A. mating with tab or tab headers 3618, 364..., 367..., 3680, 3683 mating with tab or tab headers 3647-1 mating with tab or tab headers 3618, 364..., 367..., 3680, 3683 mating with printed circuit board (by means of guide frame 3602) mating with printed circuit board mating with printed circuit board (3612 by means of guide frame 3602) 2–12 2–12 2–6 3623 1–12 3625 1–4 3626 2–12 3628 8 3625-1 2–4 3628-1 8 Insulating body 362..., PA, V2 according to UL 94 362... M08 PA1, V2 acc. to UL 94 362... M20 PA, V0 acc. to UL 94 PA, V2 according to UL 94 361..., 363... PA, V2 according to UL 94 3615, 361... M08, 363... M08 PA1, V2 according to UL 94 Contact spring 3623, 3626 CuSn, tin-plated 3625, 3628 CuSn, silver-plated Cu alloy, silver-plated CuSn, tin-plated 3623, 3626 0.22–1.0 mm2 3625, 3628 0.75–1.5 mm2 0.75–1.0 mm2 2.5 mm2 3623 10 A/0.75 mm2 at Tamb 70 °C 3623 S01, 3626 S01 5 A/0.38 mm2 at Tamb 70 °C 3625 16 A/1.50 mm2 at Tamb 70 °C 3625, 3628 12 A/1.0 mm2 at Tamb 70 °C 10.5 A at Tamb 120 °C 10 A bei at Tamb 70 °C Pole number Connectable wire section 2 Rated current 2–7 Rated voltage 1 2 glow-wire resistant (GWT 750 °C), see specification at www.lumberg.com range of values of conductors approved by laboratory tests; covering various geometries of insulation displacement terminations 0.22–0.82 mm2 3633 6 A/0.75 mm2 at Tamb 70 °C 3633 S01 4 A/0.38 mm2 at Tamb 70 °C 3636 6 A/0.75 mm2 at Tamb 70 °C 3636 S01 4 A/0.38 mm2 at Tamb 70 °C 2–12 2x12 mating with connectors 3611, 3615, 3623, 3626 3–27 3680 2–25 3683 2–27 2–26 CuZn, pre-nickel and tin-plated CuSn, tin-plated CuSn/CuZn, pre-nickel and tinplated (tabs) CuSn, tin-plated (sockets) 2.5 mm2 6 A at Tamb 70 °C 364... 10 A at Tamb 70 °C 364... V167 16 A at Tamb 70 °C 10 A at Tamb 70 °C 250 V AC 10 A at Tamb 70 °C 8 PA1, V2 according to UL 94 PA GF1, V0 according to UL 94 364... CuZn, pre-nickel and tin-plated 364... V167 CuZn, pre-nickel and silver-plated 2–8 10 A at Tamb 70 °C 2–7 2–12 PA GF1, V2 according to UL 94 PA GF1, V0 according to UL 94 CuSn, tin-plated CuSn, silver-plated CuZn, tin-plated 0.5–0.82 mm2 1.0–1.5 mm2 2.5 mm2 10 A/0.75 mm2 at Tamb 60 °C 6 A/0.75 mm2 at Tamb 90 °C 10.5 A at Tamb 120 °C 10 A at Tamb 70 °C KEYING Series 36 of RAST 5 connectors according to RAST 5 standard 360... · 361... · 362... · 3633 · 364... · 367... · 368... Indirect connectors RAST 7.5 Power™ connectors 3690 3695 RAST 7.5 Power™ tab header pitch 7.5 mm (0.295") RAST 7.5 Power™ connector for indirect mating, insulation displacement technology with exterior locking upright, with positioning spigot ment technology. Keying follow- 3636 Direct connectors are keyed by keying ribs (K), closed sides (positioning, P) and locks (V). The printed circuit board has matching reliefs. Indirect connectors are keyed by means of keying noses (K). The matching keying windows of the tab header are open (same with guide frame in combination with direct connectors). Indirect mating, for cable-to-boardconnections, insulation displace- Direct connectors 1a 1b 2a 2b 3a 3b P 1 * P1 * ing RAST 5 standard avoids mis- V K V P2 1 mating. 1c 1d 2c 2d 3c 3d K For load currents up to 25 A. All drawings in view of mating direction (*), from female to male connector. mating with tab header 3695 mating with connector 3690 A selection of proposed keyings can be found on the Internet at www.lumberg.com 3623 05 K30 Pole number 3636 05 K02 2–4 1–2 Insulating body PA1, V2 according to UL 94 PA GF1, V0 according to UL 94 Contact spring CuNiSi, silver-plated CuZn, pre-nickel and silver-plated Rated voltage 1 2 keying: P1 P2 K2/3 V1/2 V4/5 3623 05 K42 3636 05 K04 3636 05 K06 keying: P 1a 5b, K 1c 2d 3c 5d, V 1/2 3/4 keying: P 1ab 2ab 3ab 4ab 5ab, K 1c 5d, V 2/3 4/5 keying: P1 P2 V1/2 V4/5 keying: P2 K1/2 140026 · 1510-1.0 · EN 3623 05 K31 2.5 mm2 Rated current 25 A at Tamb 85 °C 500 V AC RAST 5 www.lumberg.com · [email protected] keying: P 1a 3a, K 1c 3d, V 1/2 4/5 Connectable wire section 2 S y s t e m O ve r v i e w Examples: Examples: 630 V AC glow-wire resistant (GWT 750 °C), see specification at www.lumberg.com range of values of conductors approved by laboratory tests; covering various geometries of insulation displacement terminations