UNISONIC TECHNOLOGIES CO., LTD R200LD10 LINEAR INTEGRATED CIRCUIT VOLTAGE REGULATOR DESCRIPTION The UTC R200LD10 shows a high current, high accuracy, low-dropout voltage. The features are: low dropout voltage, very low ground current. Cause the series have been designed for high current loads, so they are also used in lower current, extremely low dropout-critical systems (in which their tiny dropout voltage and ground current values are important attributes). FEATURES * Built-in ON/OFF function, * Over current protection function, * ASO protection function * Overheat protection function * 0.3A / 3.3V(R1=2KΩ) Output low dropout voltage regulator ORDERING INFORMATION Ordering Number Lead Free Halogen Free R200LD10L-TN4-L R200LD10G-TN4-L R200LD10L-TN4-R R200LD10G-TN4-R R200LD10L-TN4-T R200LD10G-TN4-T R200LD10L-TN5-R R200LD10G-TN5-R R200LD10L-TN5-T R200LD10G-TN5-T www.unisonic.com.tw Copyright © 2012 Unisonic Technologies Co., Ltd Package Packing TO-252-4 TO-252-4 TO-252-4 TO-252-5 TO-252-5 Tape Reel(Reserve Feed) Tape Reel(Standard Feed) Tube Tape Reel Tube 1 of 8 QW-R101-022.G R200LD10 PIN DESCRIPTIONS PIN NO. 1 2 3 4 5 LINEAR INTEGRATED CIRCUIT PIN NAME VIN VC VOUT VADJ GND PIN FUNCTION DC Input Voltage. On/Off Control DC Output Voltage. Output Voltage Adjustment Ground BLOCK DIAGRAM VIN 1 VC 2 3 VOUT STARTING CIRCUIT REFERENCE VOLTAGE OTP OVERCURRENT PROTECTION SOA PROTE CTION 4 VADJ 5 GND UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 2 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT ABSOLUTE MAXIMUM RATINGS (TA=25°C) PARAMETER SYMBOL RATINGS UNIT Input Voltage (Note 2) VIN 24 V ON/OFF Control Terminal Voltage (Note 2) VC 24 V Output Adjustment Pin Voltage (Note 2) VADJ 5 V Output Current IOUT 1 A Power Dissipation (with infinite heat sink) PD 8 W Junction Temperature TJ +150 °C Operating Temperature TOPR -40 ~ +85 °C Storage Temperature TSTG -40 ~ +150 °C Note: 1.Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2. All are open except GND and applicable terminals. ELECTRICAL CHARACTERISTICS (VI N=5V, VOUT=3.3 V(R1=2kΩ), IOUT=0.3A, VC=2.7V, TJ=25°C, CI=0.33μF, CO=10μF, unless otherwise specified) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNIT Input Voltage VIN 3.5 24 V Output Voltage VOUT 3.0 20 V Load Regulation ΔVOUT/ΔIOUT IOUT = 5mA~ 1A 1.0 % Line Regulation ΔVOUT/ΔVIN VIN = 4~ 10V, IOUT=5mA 1.0 Ripple Rejection RR Refer to Fig 3 60 dB Dropout Voltage VD VIN=3.5V 0.5 V Reference Voltage VREF 2.583 2.65 2.717 Temperature Coefficient of Reference TCVREF TJ =0 ~ 125°C, IOUT = 5mA ±1.0 % Voltage On-State Voltage for Control VC(ON) (Note) 2.0 V On-State Current for Control IC(ON) 200 μA On-State Voltage for Control VC(OFF) IOUT=0A 0.8 V On-State Current for Control IC(OFF) IOUT=0A,VC=0.4V -2 μA Quiescent Current IQ IOUT=0A 8 mA Output Off-State Consumption Current IQS VC=0.4V 5 μA Note: In case of VC pin, output voltage turns OFF. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 3 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT TYPICAL APPLICATION CIRCUIT UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 4 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT TEST CIRCUIT For Standard Measuring Circuit of Regulation Portion DC Input A CO=10μF CI=0.33μF 4 2 5 IC IOUT R2 R200LD10 VIN VOUT 3 3 1 R1 A A V RL IQ VOUT=VREF*(1+R2/R1) R1=2kΩ,VREF≈2.65V For Standard Measuring Circuit of Ripple Rejection Critical Rate DC Input ei + 3 3 1 IOUT R2 R200LD10 VOUT ~ VIN CO=10μF CI=0.33μF eo 4 2 5 V~ V R1 RL 2.7V f=120Hz sine wave ,ei(rms)=0.5V , VIN=5V,VOUT=3.3V(R1=2kΩ) IOUT=0.3A,RR=20log{ei(rms)/eo(rms)} UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 5 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT TYPICAL CHARACTERISTICS UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 6 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT TYPICAL CHARACTERISTICS(Cont.) UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 7 of 8 QW-R101-022.G R200LD10 LINEAR INTEGRATED CIRCUIT UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 8 of 8 QW-R101-022.G