EcoFlex® PUR Zero Halogen, Reduced Diameter, Oil Resistant, Continuous Flex Cable EcoFlex® PUR Flex Cable G et the abrasion, UV, and oil resistance of a tough zero-halogen polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600 V continuous flex cables. 20 AWG, 12 conductor cable The Smaller Continuous Flex Cable Compared to other 600 V continuous flex cables, our new EcoFlex PUR cables save you significant space and weight. The thin-wall mPPE insulation provides cables that are up to 40% smaller and 44% lighter than traditional flex cables. Tough Polyurethane Jacket The rugged, zero-halogen PUR jacket is tough enough for demanding applications in industrial machinery, mining, and outdoor applications. It offers exceptional resistance to abrasion, oils and solvents, and UV radiation. It remains flexible even at low temperatures. Traditional PUR Cable EcoFlex® PUR Specifications • 28 to 10 AWG • 2 to 36 conductors • Unshielded or braid shielding Operating Temperature • -50°C to +90°C (static) • -40°C to +80°C (dynamic) Materials • Conductors: Finely stranded tinned copper • Insulation: mPPE • Shielding: Tinned copper braid, 85% coverage • Jacket: PUR, zero halogen, slate Flex Life Cycles • 8 million and counting Bend Radius • Static: 4x • Dynamic: 6x Conductor Color Coding • Black, numbered • One green/yellow conductor Chemical Properties • Zero-halogen • Contains no heavy metals or phthalates Electrical Properties • 600 V (UL) Zero Halogen Alpha Wire’s next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. • EcoCable® • EcoWire® • EcoFlex® Cable • EcoWire® Plus • EcoCable® Mini • EcoFlex® PUR Learn more about the new EcoGen family of products at www.alphawire.com/EcoGen EcoFlex PUR cables contain no halogens, phthalates, or heavy metals, making it ideal for meeting RoHS and WEEE requirements. The Flexible Choice in Flex Cables With its rugged PUR jacket and finely stranded conductors, EcoFlex PUR cable provides 8+ million flex cycles in tough application conditions—while saving space and reducing weight. And with a wide range of conductor sizes, conductor counts, and shielded and unshielded versions, you can find the cable you need. Approvals • U L AWM 21959 (90°C/ 600 VRMS) • UL Oil Res I • UL Sunlight Resistant • CSA AWM I/II A/B FT2 • EN60332-1 Flame Behavior • EN60332-2 Flame Behavior • EN60754-2 Acid Gas Generation • EN60228 Conductors, Class 6 • EU Low Voltage Directive 2006/95/EC Availability • 100’ put-up in stock • Bulk (Min. 1000’) EcoFlex® PUR Flex Cable Unshielded 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80001 80002 2 3 Nominal Diameter Inch mm 0.140 3.56 0.146 3.71 Part Number Conductors 80003 80004 80005 80006 80007 2 3 5 7 9 Nominal Diameter Inch mm 0.150 3.81 0.156 3.96 0.179 4.55 0.192 4.88 0.231 5.87 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80008 80009 80010 80011 80012 80013 2 3 5 7 9 10 Nominal Diameter Inch mm 0.158 4.01 0.165 4.19 0.190 4.83 0.204 5.18 0.247 6.27 0.248 6.30 Part Number Conductors 80014 80015 80016 80017 80018 80019 2 3 4 6 9 10 Nominal Diameter Inch mm 0.172 4.37 0.180 4.57 0.195 4.95 0.225 5.72 0.275 6.98 0.276 7.01 20 AWG (0.523 mm2) 18 AWG (0.825 mm2) Stranding: 26/34 (26 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/34 (41 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80020 80021 80022 80023 80024 80025 80026 80027 80028 80029 80030 80031 2 3 5 6 7 9 12 18 20 25 30 36 Nominal Diameter Inch mm 0.178 4.52 0.187 4.75 0.217 5.51 0.234 5.94 0.234 5.94 0.287 7.29 0.297 7.54 0.344 8.74 0.361 9.17 0.398 10.11 0.421 10.69 0.454 11.53 Part Number Conductors 80032 80033 80034 80035 80036 80037 80038 80039 80040 2 3 4 5 7 9 12 18 25 Nominal Diameter Inch mm 0.194 4.93 0.204 5.18 0.221 5.61 0.239 6.07 0.258 6.55 0.318 8.08 0.330 8.38 0.384 9.75 0.446 11.33 EcoFlex® PUR Flex Cable Unshielded 16 AWG (1.31 mm2) 14 AWG (2.11 mm2) Stranding: 65/34 (65 x 0.16 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 105/34 (105 x 0.16 mm) Insulation thickness: 0.013 (0.33 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80041 80042 80043 80044 80045 80046 80047 80048 80049 80050* 2 3 4 5 7 9 12 18 25 36 Nominal Diameter Inch mm 0.228 5.79 0.241 6.12 0.263 6.68 0.285 7.24 0.310 7.87 0.386 9.80 0.401 10.19 0.470 11.94 0.548 13.92 0.672 17.07 Part Number Conductors 80052 80053 80054 80055 80056 80057 80058 80059* 3 4 5 7 9 12 18 25 Nominal Diameter Inch mm 0.275 6.98 0.301 7.65 0.329 8.36 0.358 9.09 0.449 11.40 0.467 11.86 0.550 13.97 0.686 17.42 *0.053 (1.35 mm) jacket thickness *0.053 (1.35 mm) jacket thickness 12 AWG (3.38 mm2) 10 AWG (5.21 mm2) Stranding: 168/34 (168 x 0.16 mm) Insulation thickness: 0.015 (0.38 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 259/34 (259 x 0.16 mm) Insulation thickness: 0.016 (0.41 mm) Jacket thickness: 0.053 (1.35 mm) Part Number Conductors 80060 80061 80062 80063 80064* 3 4 5 7 9 Nominal Diameter Inch mm 0.357 9.07 0.393 9.98 0.432 10.97 0.473 12.01 0.642 16.31 *0.053 (1.35 mm) jacket thickness More Choice! EcoFlex PUR cables can be built in other configurations. Consult Alpha Wire about your specific requirements and other available options— and for custom and composite configurations. Sample the Performance Samples of EcoFlex PUR cable are available today! Request yours at www.alphawire.com/ecogen or call 1-800-52 ALPHA Part Number Conductors 80065 80066 80067 80068 3 4 5 7 Nominal Diameter Inch mm 0.464 11.79 0.508 12.90 0.556 14.12 0.606 15.39 EcoFlex® PUR Flex Cable Braid Shielded 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80101 80102 2 3 Nominal Diameter Inch mm 0.168 4.27 0.174 4.42 Part Number Conductors 80103 80104 80105 80106 80107 2 3 4 6 8 Nominal Diameter Inch mm 0.178 4.52 0.184 4.67 0.196 4.98 0.220 5.59 0.246 6.25 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80108 80109 80110 80111 80112 80113 2 3 5 7 9 10 Nominal Diameter Inch mm 0.186 4.72 0.193 4.90 0.218 5.54 0.232 5.89 0.275 6.98 0.276 7.01 Part Number Conductors 80114 80115 80116 80117 80118 80119 2 3 4 6 9 10 Nominal Diameter Inch mm 0.200 5.08 0.208 5.28 0.223 5.66 0.253 6.43 0.303 7.70 0.304 7.72 20 AWG (0.523 mm2) 18 AWG (0.825 mm2) Stranding: 26/34 (26 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/34 (41 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80120 80121 80122 80123 80124 80125 80126 80127 80128 80129 80130 80131 2 3 5 6 7 9 12 18 20 25 30 36 Nominal Diameter Inch mm 0.206 5.23 0.215 5.46 0.245 6.22 0.262 6.65 0.262 6.65 0.315 8.00 0.325 8.25 0.372 9.45 0.389 9.88 0.426 10.82 0.449 11.40 0.488 12.40 Part Number Conductors 80132 80133 80134 80135 80136 80137 80138 80139 80140 2 3 4 5 7 9 12 18 25 Nominal Diameter Inch mm 0.222 5.64 0.232 5.89 0.249 6.32 0.267 6.78 0.286 7.26 0.346 8.79 0.358 9.09 0.412 10.46 0.676 17.17 EcoFlex® PUR Flex Cable Braid Shielded 16 AWG (1.31 mm2) 14 AWG (2.11 mm2) Stranding: 65/34 (65 x 0.16 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 105/34 (105 x 0.16 mm) Insulation thickness: 0.013 (0.33 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 80141 80142 80143 80144 80145 80146 80147 80148 80149* 2 3 4 5 7 9 12 18 25 Nominal Diameter Inch mm 0.256 6.50 0.269 6.83 0.291 7.39 0.313 7.95 0.338 8.59 0.414 10.52 0.429 10.90 0.504 12.80 0.624 15.85 Part Number Conductors 80150 80151 80152 80153 80154 80155 80156* 80157* 3 4 5 7 9 12 18 25 Nominal Diameter Inch mm 0.303 7.70 0.329 8.36 0.357 9.07 0.386 9.80 0.483 12.27 0.501 12.73 0.626 15.90 0.727 18.47 *0.053 (1.35 mm) jacket thickness *0.053 (1.35 mm) jacket thickness 12 AWG (3.38 mm2) 10 AWG (5.21 mm2) Stranding: 168/34 (168 x 0.16 mm) Insulation thickness: 0.015 (0.38 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 259/34 (259 x 0.16 mm) Insulation thickness: 0.016 (0.41 mm) Jacket thickness: 0.053 (1.35 mm) Part Number Conductors 80158 80159 80160 80161 80162* 3 4 5 7 9 Nominal Diameter Inch mm 0.385 9.78 0.421 10.69 0.460 11.68 0.507 12.88 0.683 17.35 *0.053 (1.35 mm) jacket thickness More Choice! EcoFlex PUR cables can be built in other configurations. Consult Alpha Wire about your specific requirements and other available options— and for custom and composite configurations. Sample the Performance Samples of EcoFlex PUR cable are available today! Request yours at www.alphawire.com/ecogen or call 1-800-52 ALPHA Part Number Conductors 80163 80164 80165 80166 3 4 5 7 Nominal Diameter Inch mm 0.492 12.50 0.542 13.77 0.590 14.99 0.640 16.26 Cables you trust. Service you deserve. Superior availability Every application is critical and cable failure is not an option when the safety of your equipment and personnel is paramount. Specify Alpha Wire products since the integrity of your system is only as robust as the products you use. Alpha Wire offers wire and cable from stock in most sizes and constructions, in both small and large put-ups, so you can order it when you need it. Our products are available for same-day shipment, eliminating long lead times. GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom TW16 6RT Tel: 01 932 772 422 Fax: 01 932 772 433 E-mail: [email protected] Service and support, second-to-none Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you to select the right Alpha product for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the wire or cable you need. Can’t find what you’re looking for? Design the cable to your specification. It’s easy, just visit www.alphawire.com! ASIA PACIFIC Alpha Wire Silver Center | Room 1712 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Alpha Wire’s next generation of eco-friendly, high-performance wire and cable, designed to provide better performance in a smaller package. ©2015 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. EcoCable, EcoCable Mini, EcoFlex, EcoFlex PUR, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire. Lit. No. PURFlex-1505 Supersedes: New