SERIES: 12 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY
up to 12 W power
universal input (90~264 Vac)
single regulated output from 5~12 V
over voltage, over current, and short circuit protections
TUV safety approvals
level V efficiency
custom designs available
U
•
•
•
•
•
•
•
ED
FEATURES
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
2.5
12
50
V
1
12
120
V
EPSA050250UE
5
EPSA120100UE
12
efficiency
level
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
O
PART NUMBER KEY
N
Notes:
TI
MODEL
N
RoHS
IS
C
EPSA050250UE - XX - EJ - CXX
Base Number
DC Plug Type
Factory
Designation
D
example of 5 Vdc, 2.5 A
cui.com
Reserved for Custom
Configurations
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: 12 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/21/2012 │ page 2 of 5
INPUT
conditions/description
min
voltage
90
frequency
47
current
nom
max
units
264
Vac
63
Hz
ED
parameter
0.4
inrush current
at 115 Vac, full load, cold start
input fuse
at 250 V
30
OUTPUT
parameter
conditions/description
min
nom
2
A
max
units
±5
%
U
line regulation
load regulation
±5
start-up
at 110 Vac, 50 Hz, 80% max. load
PROTECTIONS
parameter
conditions/description
over voltage protection
output shut down
short circuit protection
TI
over current protection
%
2
10
N
hold-up
parameter
conditions/description
min
input to output at 10 mA for 2 seconds
input to output at 500 Vdc
N
isolation voltage
isolation resistance
ms
200
%
nom
max
units
3,000
Vac
10
MΩ
EN 60950-1, CE
EMI/EMC
EN 55022 Class B, AS/NZS CISPR 22 Class B, EN 61000-3-(2,3), IEC 61000-4-(2,3,4,5,6,8,11)
MTBF
O
safety approvals
RoHS compliant
s
output shut down and auto restart
SAFETY & COMPLIANCE
leakage current
A
0.25
mA
300,000
hours
max
units
yes
at full load, 25°C, Telcordia SR-332, Issue 2
IS
C
ENVIRONMENTAL
parameter
conditions/description
min
0
40
°C
storage temperature
-25
85
°C
operating humidity
10
95
%
storage humidity
10
95
%
D
operating temperature
nom
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: 12 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/21/2012 │ page 3 of 5
MECHANICAL
conditions/description
dimensions
2.953 x 1.378 x 1.850 (75 x 35 x 47 mm)
min
input plug
fixed Europe
max
units
inch
MECHANICAL DRAWING
units: mm[inch]
47.0 1.850
1.0
N
U
35.00 1.378
1.0
typ
ED
parameter
IS
C
O
N
TI
75.0 2.953
1.0
D
DC CORD
cord length
cui.com
MODEL NO.
CABLE GAUGE
CORD LENGTH
EPSA050250UE
18 AWG
1,500 mm ±30
EPSA120100UE
22 AWG
1,500 mm +50/-30
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: 12 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/21/2012 │ page 4 of 5
OUTPUT PLUG OPTIONS
IJĵġƲıįĶ
IJĵġƲıįĶ
P1R
U
P1
ł
Ń
ń
ń
C
Unit
P5/P5R
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.3
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
TI
Right Angle PXR
O
EIAJ Plugs
IS
C
ń
Standard PXX
ł
Ń
ń
ł
Ń
B
N
ł
Ń
Locking DC Plug
A
N
ł
Ń
Standard DC Plug
Standard PX
ED
ǹĴįĶġĬıİĮıįIJ
ǹĴįĶġĬıİĮıįIJ
3.5 mm Phono Plug
ń
Right Angle PXXR
EIAJ
A
P12/P12R
EIAJ-1
2.35
0.7
9.5
mm
P13/P13R
EIAJ-2
4.0
1.7
9.5
mm
P14/P14R
EIAJ-3
4.75
1.7
9.5
mm
D
Stripped and Tinned
ijĶƲĶ
DC PLUG TYPE
ST
stripped and tinned
PXX X X
Plug type
Plug angle:
“blank” = standard
R = right angle
Plug polarity:
“blank” = N/A
P = center positive
N = center negative
cui.com
B
C
Unit
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: 12 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/21/2012 │ page 5 of 5
REVISION HISTORY
description
date
03/08/2010
1.0
initial release
1.01
updated output plug options
1.02
new template applied
1.03
ED
rev.
11/11/2010
01/24/2012
P7/P7R B dimension updated, V-Infinity branding removed, safety
and EMI/EMC data updated
08/21/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.