date 04/18/2013 page 1 of 5 SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • up to 6 W power compact size single output from 3~24 V over voltage and short circuit protections custom designs available RoHS MODEL output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) EPS030100 3 1 3 100 IV EPS033100 3.3 1 3.3 100 IV EPS045100 4.5 1 4.5 100 V EPS050100 5 1 5 100 V EPS060100 6 1 6 100 V EPS075080 7.5 0.8 6 100 IV EPS090066 9 0.66 6 100 V EPS120050 12 0.5 6 120 V EPS150040 15 0.4 6 150 V EPS180033 18 0.33 6 180 V EPS240025 24 0.25 6 240 IV Notes: efficiency level 1. At full load, 100 ~ 132 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors. PART NUMBER KEY EPS030100 - PXXXX - CXX Base Number example of 3 Vdc, 1 A DC Plug Type cui.com Reserved for Custom Configurations CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY date 04/18/2013 │ page 2 of 5 INPUT parameter conditions/description min voltage typ 100 frequency 47 current inrush current1 no load power consumption Notes: 15V, 18V and 24V model at 100 Vac at 132 Vac all other models at 132 Vac level IV models level V models max units 132 Vac 63 Hz 0.15 A 15 30 A A 40 A 0.5 0.3 W W max units 1. inrush lasts no longer than 0.5 ms before settling to steady state current OUTPUT parameter conditions/description line regulation all other models 7.5V model min typ ±1 ±2 load regulation temperature coefficient 0 ~ 40°C, full load, after initial 1 hour warm-up start-up time needed to reach regulation hold-up at 115 Vac, full load % % ±5 % ±0.02 %/°C 3 10 s ms PROTECTIONS parameter conditions/description over voltage protection clamped by internal protection zener short circuit protection continuous, auto-recovery upon removal of short min typ min typ max units max units 3,000 4,242 Vdc Vdc SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output at 10 mA for 1 minute isolation resistance input to output at 500 Vdc safety approvals UL 1310 safety class II EMI/EMC FCC Part 15 Class B 100 MΩ leakage current RoHS compliant 0.25 mA max units yes ENVIRONMENTAL parameter conditions/description min operating temperature typ 0 40 °C storage temperature -10 70 °C operating humidity 20 80 % storage humidity 10 90 % cui.com CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY date 04/18/2013 │ page 3 of 5 MECHANICAL parameter conditions/description dimensions 62.33 x 26.8 x 42 (2.454 x 1.055 x 1.654 inch) min input plug fixed US units: mm tolerance: X.X ±0.5 X.XX ±0.03 42 1.0 26.8 1.0 12.7 62.33 1.0 22.3X18.0 1830 100 6.3 3.0 (TYP) cui.com max units mm MECHANICAL DRAWING 17.06 1.18 typ CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY date 04/18/2013 │ page 4 of 5 OUTPUT PLUG OPTIONS IJĵġƲıįĶ ǹĴįĶġĬıİĮıįIJ ǹĴįĶġĬıİĮıįIJ 3.5 mm Phono Plug IJĵġƲıįĶ P1 P1R Standard DC Plug ń Standard PX Ń ł Ń ł ń Right Angle PXR A B C Unit P5/P5R 5.5 2.1 121 mm P6/P6R 5.5 2.5 12 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm 3.8 1.05 9.5 mm P9/P9R Locking DC Plug Notes: 1. EPS050100-P5P has a 9.5mm dc plug length ł Ń ń A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm EIAJ Plugs EIAJ A B C D Unit P12/P12R EIAJ-1 2.35 0.7 9.5 NA mm P13/P13R EIAJ-2 4.0 1.7 9.5 5.0 mm P14/P14R EIAJ-3 4.75 1.7 9.5 5.0 mm Ń ł Ń ł ń ń Standard PXX Right Angle PXXR Ņ Stripped and Tinned ijĶƲĶ DC PLUG TYPE ST stripped and tinned PXX X X Plug type Plug angle: “blank” = standard R = right angle Plug polarity: “blank” = N/A P = center positive N = center negative cui.com CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY date 04/18/2013 │ page 5 of 5 REVISION HISTORY rev. description date 1.0 initial release 06/29/2006 1.01 applied new spec template 12/28/2010 1.02 removed multiple models, applied new spec template 05/26/2011 1.03 updated P7/P7R B dimension 04/13/2012 1.04 V-Infinity branding removed, safety and EMI/EMC data updated 08/16/2012 1.05 added 7.5V model 09/24/2012 1.06 updated P5 & P6 plug lengths 04/18/2013 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.