CUI EPS-6W

date
04/18/2013
page
1 of 5
SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
up to 6 W power
compact size
single output from 3~24 V
over voltage and short circuit protections
custom designs available
RoHS
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
EPS030100
3
1
3
100
IV
EPS033100
3.3
1
3.3
100
IV
EPS045100
4.5
1
4.5
100
V
EPS050100
5
1
5
100
V
EPS060100
6
1
6
100
V
EPS075080
7.5
0.8
6
100
IV
EPS090066
9
0.66
6
100
V
EPS120050
12
0.5
6
120
V
EPS150040
15
0.4
6
150
V
EPS180033
18
0.33
6
180
V
EPS240025
24
0.25
6
240
IV
Notes:
efficiency
level
1. At full load, 100 ~ 132 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
PART NUMBER KEY
EPS030100 - PXXXX - CXX
Base Number
example of 3 Vdc, 1 A
DC Plug Type
cui.com
Reserved for Custom
Configurations
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/18/2013 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
typ
100
frequency
47
current
inrush current1
no load power consumption
Notes:
15V, 18V and 24V model
at 100 Vac
at 132 Vac
all other models
at 132 Vac
level IV models
level V models
max
units
132
Vac
63
Hz
0.15
A
15
30
A
A
40
A
0.5
0.3
W
W
max
units
1. inrush lasts no longer than 0.5 ms before settling to steady state current
OUTPUT
parameter
conditions/description
line regulation
all other models
7.5V model
min
typ
±1
±2
load regulation
temperature coefficient
0 ~ 40°C, full load, after initial 1 hour warm-up
start-up
time needed to reach regulation
hold-up
at 115 Vac, full load
%
%
±5
%
±0.02
%/°C
3
10
s
ms
PROTECTIONS
parameter
conditions/description
over voltage protection
clamped by internal protection zener
short circuit protection
continuous, auto-recovery upon removal of short
min
typ
min
typ
max
units
max
units
3,000
4,242
Vdc
Vdc
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 Vdc
safety approvals
UL 1310
safety
class II
EMI/EMC
FCC Part 15 Class B
100
MΩ
leakage current
RoHS compliant
0.25
mA
max
units
yes
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
typ
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
cui.com
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/18/2013 │ page 3 of 5
MECHANICAL
parameter
conditions/description
dimensions
62.33 x 26.8 x 42 (2.454 x 1.055 x 1.654 inch)
min
input plug
fixed US
units: mm
tolerance: X.X ±0.5
X.XX ±0.03
42
1.0
26.8
1.0
12.7
62.33
1.0
22.3X18.0
1830 100
6.3
3.0
(TYP)
cui.com
max
units
mm
MECHANICAL DRAWING
17.06
1.18
typ
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/18/2013 │ page 4 of 5
OUTPUT PLUG OPTIONS
IJĵġƲıįĶ
ǹĴįĶġĬıİĮıįIJ
ǹĴįĶġĬıİĮıįIJ
3.5 mm Phono Plug
IJĵġƲıįĶ
P1
P1R
Standard DC Plug
ń
Standard PX
Ń
ł
Ń
ł
ń
Right Angle PXR
A
B
C
Unit
P5/P5R
5.5
2.1
121
mm
P6/P6R
5.5
2.5
12
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
3.8
1.05
9.5
mm
P9/P9R
Locking DC Plug
Notes:
1. EPS050100-P5P has a 9.5mm dc plug length
ł
Ń
ń
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ Plugs
EIAJ
A
B
C
D
Unit
P12/P12R
EIAJ-1
2.35
0.7
9.5
NA
mm
P13/P13R
EIAJ-2
4.0
1.7
9.5
5.0
mm
P14/P14R
EIAJ-3
4.75
1.7
9.5
5.0
mm
Ń
ł
Ń
ł
ń
ń
Standard PXX
Right Angle PXXR
Ņ
Stripped and Tinned
ijĶƲĶ
DC PLUG TYPE
ST
stripped and tinned
PXX X X
Plug type
Plug angle:
“blank” = standard
R = right angle
Plug polarity:
“blank” = N/A
P = center positive
N = center negative
cui.com
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/18/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
06/29/2006
1.01
applied new spec template
12/28/2010
1.02
removed multiple models, applied new spec template
05/26/2011
1.03
updated P7/P7R B dimension
04/13/2012
1.04
V-Infinity branding removed, safety and EMI/EMC data updated
08/16/2012
1.05
added 7.5V model
09/24/2012
1.06
updated P5 & P6 plug lengths
04/18/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.