For more information, please visit the product page. date 09/07/2012 page 1 of 5 SERIES: VASD0.25-SIP │ DESCRIPTION: DC-DC CONVERTER FEATURES d 0.25 W isolated output industry standard 6 pin SIP package dual unregulated outputs 1,000 V isolation short circuit protection UL safety approvals wide temperature (-40~85°C) efficiency up to 66% RoHS VASD0.25-S5-D9-SIP output voltage output current output power ripple and noise1 efficiency (Vdc) max (mA) max (W) max (mVp-p) typ (%) ±9 ±13.8 0.25 75 64 ±15 ±8.3 0.25 75 65 ±9 ±13.8 0.25 75 63 10.8~13.2 ±12 ±10.4 0.25 75 64 21.6~26.4 ±5 ±25 0.25 75 63 typ (Vdc) range (Vdc) 5 4.5~5.5 5 4.5~5.5 VASD0.25-S12-D9-SIP 12 10.8~13.2 VASD0.25-S12-D12-SIP 12 VASD0.25-S24-D5-SIP 24 1. ripple and noise are measured at 20 MHz BW 2. unbalanced load: ±5% is co Notes: nt VASD0.25-S5-D15-SIP in input voltage MODEL ue • • • • • • • • D PART NUMBER KEY VASD0.25 - SXX - DXX -SIP Base Number Input Voltage cui.com Output Voltage Packaging Style For more information, please visit the product page. CUI Inc │ SERIES: VASD0.25-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/07/2012 │ page 2 of 5 INPUT parameter conditions/description min typ max units operating input voltage 5 V model 12 V model 24 V model 4.5 10.8 21.6 5 12 24 5.5 13.2 26.4 Vdc Vdc Vdc conditions/description min typ max units 1.2 % 15 15 15 15 % % % % line regulation for Vin change of 1% load regulation measured from 10% load to full load 5 V model 9 V model 12 V model 15 V model voltage accuracy see derating curves switching frequency 100% load, input voltage range temperature coefficient Notes: 1. test ripple and noise by “parallel cable” method. parameter in PROTECTIONS 10.5 8.3 6.8 6.3 ue parameter d OUTPUT conditions/description short circuit protection SAFETY AND COMPLIANCE min kHz ±0.03 %/°C typ units 1 s max units for 1 minute at 1 mA max. 1,000 Vdc isolation resistance at 500 Vdc 1,000 MΩ safety approvals UL 60950-1 (E222736) 3,500,000 hours co yes nt conditions/description isolation voltage RoHS compliant typ max parameter MTBF min 100 ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature typ units 85 °C -55 125 °C 95 % 25 °C 300 °C non-condensing is storage humidity max -40 at full load lead temperature 1.5 mm from case for 10 seconds 15 D temperature rise cui.com For more information, please visit the product page. CUI Inc │ SERIES: VASD0.25-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/07/2012 │ page 3 of 5 DERATING CURVES 1. output power vs. ambient temperature 2. output voltage vs. output current +10% 80 60 40 -40 -20 0 20 40 60 85 100 conditions/description dimensions 0.772 x 0.236 x 0.374 (19.60 x 6.00 x 9.50 mm) case material plastic (UL94-V0) weight typ max 2.1 g 6.00 [0.236] 1 2 4 5 6 D ] [0.160 is 2.54 [1.00] 19.60[0.772] PIN CONNECTIONS 0.50 [0.020] PIN cui.com units inch co 1.25 [0.049] 100% nt MECHANICAL DRAWING min in parameter 9.50 [0.374] 50% -7.5% Output Current (%) MECHANICAL 2.10±0.50 [0.083±0.020] -2.5% 10% Ambient Temperature (°C) units: mm [inches] tolerance: ±0.25 [±0.010] pin section tolerance: ±0.10 [±0.004] +2.5% Voltage ue 20 +5% Nominal d Output Voltate (%) Load (%) 100 FUNCTION 1 Vin 2 GND 4 -Vo 5 0V 6 +Vo For more information, please visit the product page. CUI Inc │ SERIES: VASD0.25-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/07/2012 │ page 4 of 5 APPLICATION NOTES Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Overload Protection Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. 3. Filtering In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference (Figure 1). ue d 1. is co Figure 2 nt Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). D 4. in Figure 1 cui.com For more information, please visit the product page. CUI Inc │ SERIES: VASD0.25-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/07/2012 │ page 5 of 5 REVISION HISTORY description date 1.0 initial release 02/19/2008 1.01 new template applied; V-Infinity branding removed; VASD0.25-S5D5-SIP, VASD0.25-S5-D12-SIP, VASD0.25-S12-D5-SIP, VASD0.25S12-D15-SIP, VASD0.25-S24-D9-SIP, VASD0.25-S24-D12-SIP and VASD0.25-S24-D15-SIP discontinued 08/06/2012 1.02 template updated 1.03 discontinued d rev. 09/04/2012 09/25/2012 D is co nt in ue The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.