SERIES: VWRAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
1 W isolated output
wide input (2:1)
industry standard 8 pin SIP package
dual unregulated outputs
1,500 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 78%
U
•
•
•
•
•
•
•
•
ED
FEATURES
input
voltage
VWRAS1-D5-D5-SIP
typ
(Vdc)
range
(Vdc)
5
4.5~9.0
VWRAS1-D5-D9-SIP
5
4.5~9.0
VWRAS1-D5-D12-SIP
5
4.5~9.0
output
voltage
(Vdc)
±5
5
4.5~9.0
12
9.0~18.0
12
12
VWRAS1-D12-D15-SIP
12
VWRAS1-D24-D5-SIP
24
VWRAS1-D24-D9-SIP
VWRAS1-D24-D12-SIP
VWRAS1-D24-D15-SIP
VWRAS1-D48-D15-SIP
Notes:
efficiency
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
±10
±100
1
150
71
±9
±5
±55
1
150
72
±4
±42
1
150
73
±15
±3
±33
1
150
73
±5
±10
±100
1
150
75
9.0~18.0
±9
±5
±55
1
150
76
9.0~18.0
±12
±4
±42
1
150
77
9.0~18.0
±15
±3
±33
1
150
76
18.0~36.0
±5
±10
±100
1
150
76
24
18.0~36.0
±9
±5
±55
1
150
77
24
18.0~36.0
±12
±4
±42
1
150
78
24
18.0~36.0
±15
±3
±33
1
150
78
48
36.0~72.0
±9
±5
±55
1
150
76
48
36.0~72.0
±15
±3
±33
1
150
78
IS
C
VWRAS1-D48-D9-SIP
ripple
and noise1
±12
O
VWRAS1-D12-D9-SIP
output
power
min
(mA)
N
VWRAS1-D5-D15-SIP
VWRAS1-D12-D5-SIP
VWRAS1-D12-D12-SIP
output
current
TI
MODEL
N
RoHS
1. ripple and noise are measured at 20 MHz BW
D
PART NUMBER KEY
Base Number
VWRAS1 - DXX - DXX -SIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
5 Vdc model
12 Vdc model
24 Vdc model
48 Vdc model
4.5
9.0
18.0
36.0
5
12
24
48
9.0
18.0
36.0
72.0
Vdc
Vdc
Vdc
Vdc
parameter
conditions/description
min
line regulation
input voltage from low to high
load regulation
measured from 10% load to full load
voltage accuracy
see derating curves
switching freDuency
100% load, nominal input
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute at 1 mA max.
isolation resistance
at 500 Vdc
RoHS compliant
yes
ENVIRONMENTAL
min
conditions/description
±0.5
±1.0
%
±1
±3
%
550
max
units
typ
max
units
Vdc
1,000
MΩ
1,000,000
hours
min
typ
max
units
-40
85
°C
-55
125
°C
15
1.5 mm from case for 10 seconds
D
cui.com
kHz
%/°C
typ
non-condensing
at full load
IS
C
lead temperature
%
1,500
O
storage humidity
temperature rise
min
N
MTBF
N
conditions/description
short circuit protection
TI
parameter
storage temperature
units
±0.03
PROTECTIONS
operating temperature
max
±0.5
180
temperature coefficient
parameter
typ
±0.2
U
OUTPUT
ED
parameter
95
%
35
°C
300
°C
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 3 of 5
DERATING CURVES
MECHANICAL
N
Operating Temp.( C )
U
ED
1. output power vs. ambient temperature
conditions/description
dimensions
0.866 x 0.374 x 0.473 (22.00 x 9.50 x 12.00 mm)
min
case material
plastic (UL94-V0)
typ
MECHANICAL DRAWING
IS
C
O
N
units: mm
tolerance: ±0.25
pin section tolerance: ±0.10
D
PIN CONNECTIONS
cui.com
max
units
inch
TI
parameter
PIN
FUNCTION
1
GND
2
Vin
3
CTRL
5
NC
6
+Vo
7
0V
8
-Vo
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 4 of 5
APPLICATION NOTES
Vout
±330
±9 V
±220
±12 V
±100
±15 V
±47
±24 V
±22
CTRL Terminal
When open or high impedance, the converter will work well; When this pin is ‘high’; the converter will shutdown; It should be noted
that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter.
N
1.
±5 V
U
Table 1
Cout/μF (max)
ED
-All of the VWRAS1-SMT Series have been tested according to the following recommended testing circuit before leaving the factory.
This series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1).
TI
Figure 1
Input Current(A)
Input current
While using the unstable power source, please ensure the output voltage and ripple voltage do not exceed indexes of the converter.
The preceding power source must be able to provide for converter sufficient starting current lp. (Figure 1)
Ip
N
Input Voltage
Range
O
Input Voltage (V)
D
IS
C
No parallel connection or plug and play.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 5 of 5
REVISION HISTORY
description
date
1.0
initial release
07/23/2007
1.02
new template applied, V-Infinity branding removed, VWRAS1-D48-D5SIP and VWRAS1-D48-D12-SIP discontinued
08/06/2012
1.03
picture updated
09/07/2012
ED
rev.
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.