CS60-xxx

Document 134
50/60 Hz Current Sensors – CS60 Series
The CS60 series is designed to measure current from 5
to 100 Arms. Applications include sensing branch circuit
overload and detecting load drop or shutdown. The sensor functions as the encapsulated secondary of a current
transformer, while the conductor carrying the current to
be measured serves as the “one turn primary.” Sensitivity
may be enhanced by increasing primary turns.
These parts are mountable on printed circuits and have a
third terminal added for mechanical stability.
Samples of these and other current sensors are available
for evaluation. To request samples, contact Coilcraft or visit
www.coilcraft.com.
Part number
Sensed
Vout
current (Irms)tolerance
CS60-050L
CS60-075L
CS60-100L
Typical Response
5-50 A rms±10%
5-75 A rms±10%
5-100 A rms±10%
(For sensed current below 10 A rms, see CS60-010 data sheet)
1. Ambient temperature range –40°C to +85°C.
2. Electrical specifications at 25°C.
VOUT (mVolts rms)
Weight 13.8 – 15.4 g
Terminations Tin-silver over copper
Packaging 30 per tray
0.350 min
8,89
Parts manufactured
prior to February, 2012
may be marked
differently.
Part number
CS60-0xxL
Internal code
XXXXY
Current (A rms)
Typical Circuit
1.25 max
31,75
0.042 ±0.002
dia
1,07 ±0,05
0.600 ±0.010
15,24 ±0,254
0.250 ±0.010
6,35 ±0,254
0.150 ±0.030
3,81 ±0,762
Irms
1
4
1
0.750 max
19,05
4
2
220
2
Vout rms
1.10 max
27,94
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Dimensions are in
inches
mm
Document 134 Revised 02/22/12
© Coilcraft Inc. 2012
This product may not be used in medical of high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.