ICPTest_Low_Rho_SMD pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
PTC
Product #:
Low Rho SMD Series
Issue Date:
March 26, 2012
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the Low Rho SMD Series RoHS-Compliant series products
manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:.
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
7
8
9
Raw Material Part Number
HDPE/LR5900
TiC
Cu/Ni 10Z 13"
(NIMI-CF-HR-35)
MW-G/U
H99.95S
ZSR-150W
IT-150BS
Phosphor Copper Anode Ball
DSR-2200 TT-19G
2
Raw Material Description
Polyethylene
Ceramic Filler
Page(s)
3-11
12-20
Nickel Copper Foil
Copper Foil
Tin
Ink Acrylic- White
Prepreg (PP)
Plated Copper
Ink Acrylic- Green
21-25
26-30
31-35
36-44
45-53
54-58
59-66
Test Report
Applicant:
Number : TWNC00234519S2
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 30, 2011
This is to supersede
report NO. TWNC00234519S1
dated Dec 19, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Polyethylene
Part Number
: HDPE/LR5900
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Antimony (Sb) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
White Powder
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
White Powder
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
Lead (Pb) content
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to USEPA 3052, by
microwave digestion until the tested
Antimony (Sb) content samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MSD
Biphenyls (PBBs)
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
Polybrominated
1.0:2008 in annex A, by solvent
Diphenyl Ethers
extraction and determined by GC-MSD
(PBDEs)
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by ion chromatography
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MSD
Hexabromocyclododecane With reference to USEPA 3540C, by
solvent extraction and determined by
(HBCDD)
GC-MSD
Reporting Limit
2 ppm
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234519S2
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234521S2
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 30, 2011
This is to supersede
report NO. TWNC00234521S1
dated Dec 19, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ceramic filler
Part Number
: TiC
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Antimony (Sb) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
Black Powder
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Black Powder
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to USEPA 3052, by
microwave digestion until the tested
Antimony (Sb) content
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MSD
Biphenyls (PBBs)
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
Polybrominated
1.0:2008 in annex A, by solvent
Diphenyl Ethers
extraction and determined by GC-MSD
(PBDEs)
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by ion chromatography
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MSD
Hexabromocyclododecane With reference to USEPA 3540C, by
solvent extraction and determined by
(HBCDD)
GC-MSD
Reporting Limit
2 ppm
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234521S2
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234522S1
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 19, 2011
This is to supersede
report NO. TWNC00234522
dated Dec 01, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Nickel/Cu Foil
Part Number
: Cu/Ni 10Z 13”
(NIMI-CF-HR-35)
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234522S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery / Dark Grey
Foil
ND
ND
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234522S1
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234522S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234522S1
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234525S2
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 30, 2011
This is to supersede
report NO. TWNC00234525S1
dated Dec 19, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Copper Foil
Part Number
: MW-G/U
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234525S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Antimony (Sb) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Coppery Foil
ND
ND
ND
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234525S2
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Antimony (Sb)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to USEPA 3052, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234525S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234525S2
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234533S1
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 19, 2011
This is to supersede
report NO. TWNC00234533
dated Dec 01, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Tin
Part Number
: H99.95S
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234533S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Result (ppm)
Grey Paste
ND
446
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Dec 01, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234533S1
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Number : TWNC00234533S1
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234533S1
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234523S1
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 19, 2011
This is to supersede
report NO. TWNC00234523
dated Dec 01, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ink (Acrylic) - White
Part Number
: ZSR-150W
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
Submitted Samples
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Submitted Samples
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample =
mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
Chromium VI (Cr6+)
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MSD
Biphenyls (PBBs)
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
Diphenyl Ethers
extraction and determined by GC-MSD
(PBDEs)
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by ion chromatography
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MSD
With reference to USEPA 3540C, by
Hexabromocyclododecane
solvent extraction and determined by
(HBCDD)
GC-MSD
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234523S1
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234524S2
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 30, 2011
This is to supersede
report NO. TWNC00234524S1
dated Dec 19, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: PP
Part Number
: IT-150BS
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 28, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Antimony (Sb) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
Submitted Samples
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Submitted Samples
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 28, 2011 To Nov 30, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to USEPA 3052, by
Antimony (Sb) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MSD
Biphenyls (PBBs)
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
Polybrominated
1.0:2008 in annex A, by solvent
Diphenyl Ethers
extraction and determined by GC-MSD
(PBDEs)
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by ion chromatography
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MSD
Hexabromocyclododecane With reference to USEPA 3540C, by
solvent extraction and determined by
(HBCDD)
GC-MSD
Reporting Limit
2 ppm
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234524S2
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00234526S1
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 19, 2011
This is to supersede
report NO. TWNC00234526
dated Dec 01, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Plated Copper
Part Number
: Phosphor Copper Anode Ball
Date Sample Received
: Nov 25, 2011
Date Test Started
: Nov 29, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234526S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Coppery Metal
ND
ND
ND
Negative
(< 0.02)(#)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
#
= Due to the insufficient sample area, reduced total sample
surface of 30 cm2 was used and the dilution factor was
adjusted accordingly.
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Nov 25, 2011
: Nov 29, 2011 To Dec 01, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234526S1
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex B, by boiling
content
water extraction and determined by
UV-Vis spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Number : TWNC00234526S1
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00234526S1
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00246534
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Mar 09, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Acrylic(Green ink)
Part Number
: DSR-2200 TT-19G
Date Sample Received
: Mar 06, 2012
Date Test Started
: Mar 06, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Green Paste
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Antimony (Sb) Content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Others
Perfluorooctane Sulfonates (PFOS)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Mar 06, 2012
: Mar 06, 2012 To Mar 09, 2012
Page 2 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Antimony (Sb)
Content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to USEPA 3052, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
2 ppm
1 ppm
Page 3 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅲ) Test Method:
Test Item
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Perfluorooctane
Sulfonates
(PFOS)
Test Method
Reporting Limit
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
5 ppm
extraction and determined by GC-MS and
further HPLC-DAD confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
5 ppm
extraction and determined by GC-MS and
further HPLC-DAD confirmation when
necessary.
With reference to EN 14582:2007 by
50 ppm
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
With reference to CEN/TS 15968_2010, by
solvent extraction and determined by
10 ppm
LC-MS-MS.
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Heavy Metal (Sb) Contents
Reference Standard:USEPA 3052
Sampling/grinding or cutting
Weigh sample and digest in
microwave digestion oven with
suitable acid
Confirm the tested samples are
totally dissolved
Transfer the digested solution
and make up with deionized
water
Analyzed by ICP-OES
End of Report
Page 7 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00246534
Test Conducted
Photo
Page 8 of 8
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401