ICPTest_391 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
SP
Product #:
391
Issue Date:
May 12, 2010
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Environmental Data Coordinator>
(1) Parts, sub-materials and unit parts
This document covers the
SP
RoHS-Compliant series products manufactured
by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:.
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
Raw Material Part Number
DRCUxxx
LOZZ194 (692213)
910-017 (T6626)
867-002 (G3813)
Raw Material Description
Element-Melting Wire
Solder Wire
Plastic Cap
Socket with Pin
2
Page(s)
3-7
8-12
13-19
20-26
Test Report
Applicant:
Number : TWNC00146749
Littelfuse Philippines Inc.
LIMA Technology Center,
Lipa City, Malvar, Batangas
Date
: Feb 01, 2010
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Element
Style / Item No.
: DRCUXXX
Date Sample Received
: Jan 27, 2010
Date Test Started
: Jan 28, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146749
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silver Metal Wire
ND
59
ND
Negative
(< 0.02)
Remarks: ppm = parts per million based on weight of tested sample = mg/kg
ND = Not Detected
<
= Less Than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter
Negative = A negative test result indicated positive observation
was not found at the time of testing. When the spot test
showed a negative result, the boiling water extraction
procedure shall be used to verify the result.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Jan 27, 2010
: Jan 28, 2010 to Feb 01, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146749
Test Conducted
(Ⅲ) Test Method:
Testing Item
Testing Method
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Cadmium (Cd) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Lead (Pb) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
Mercury (Hg) content
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in annex B, by
Chromium VI (Cr6+) content
boiling water extraction and
(mg/kg with 50cm2)
determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting Limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146749
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146749
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00146748
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Feb 02, 2010
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Solder Wire
Style / Item No.
: LOZZ194(692213)
Date Sample Received
: Jan 27, 2010
Date Test Started
: Jan 28, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146748
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal Wire
ND
259
ND
Negative
(< 0.02)
Remarks: ppm = parts per million based on weight of tested sample = mg/kg
ND = Not Detected
<
= Less Than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter
Negative = A negative test result indicated positive observation
was not found at the time of testing. When the spot test
showed a negative result, the boiling water extraction
procedure shall be used to verify the result.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Jan 27, 2010
: Jan 28, 2010 To Feb 02, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146748
Test Conducted
(Ⅲ) Test Method:
Testing Item
Testing Method
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Cadmium (Cd) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Lead (Pb) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
Mercury (Hg) content
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in annex B, by
Chromium VI (Cr6+) content
boiling water extraction and
(mg/kg with 50cm2)
determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting Limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146748
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146748
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00146743
Littelfuse Philippines Inc.
LIMA Technology Center,
Lipa City, Malvar, Batangas
Date
: Feb 01, 2010
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Plastic Cap
Style / Item No.
: 910-017
Date Sample Received
: Jan 27, 2010
Date Test Started
: Jan 28, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
Brown Material
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
Brown Material
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
150
ND
ND
Remarks: ppm = parts per million based on wet weight of tested sample = mg/kg
ND = Not Detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Jan 27, 2010
: Jan 28, 2010 to Feb 01, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
(Ⅲ) Test Method:
Testing Item
Testing Method
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Cadmium (Cd) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Lead (Pb) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
Mercury (Hg) content
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in annex C, by
Chromium VI (Cr6+) content
alkaline digestion and determined
by UV-Vis spectrophotometer.
With reference to IEC 62321
edition 1.0:2008 in annex A, by
Polybrominated Biphenyls solvent extraction and
determined by GC-MSD and further
(PBBs)
HPLC confirmation when
necessary.
With reference to IEC 62321
edition 1.0:2008 in annex A, by
solvent extraction and
Polybrominated Diphenyl
determined by GC-MSD and further
Ethers (PBDEs)
HPLC confirmation when
necessary.
With reference to EN 14582:2007
by combustion flask with oxygen
Halogen Content
and determined by ion
chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting Limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents
Reference Standard: IEC 62321 edition 1.0:2008
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard:EN 14582
sampling/grinding or
cutting
add absorbent in a
combustion flask &
place weighed sample in
equipment
fill the combustion
flask with oxygen
ignite then leave the
flask at room
temperature
transfer the absorbent
into a volumetric flask
make up with deionized
water
analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146743
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00146740
Littelfuse Philippines Inc.
LIMA Technology Center,
Lipa City, Malvar, Batangas
Date
: Feb 01, 2010
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Socket with Pin
(A)Body (B)Pin
Style / Item No.
: 867-002
Date Sample Received
: Jan 27, 2010
Date Test Started
: Jan 29, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (for non-metal material)
Chromium VI (Cr6+) content (mg/kg with 50cm2)
(by boiling water extraction on metal)
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
(2)
(3)
(1)
ND
ND
ND
ND
ND
ND
ND
--
ND
216
ND
--
--
Negative
(< 0.02)
(#)
Negative
(< 0.02)
(#)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
-----------
-----------
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
-----------
-----------
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
(2)
(3)
(1)
ND
523
ND
ND
-----
-----
Remarks: ppm = parts per million based on weight of tested sample = mg/kg
ND = Not Detected
<
= Less Than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter
Negative = A negative test result indicated positive observation
was not found at the time of testing. When the spot test
showed a negative result, the boiling water extraction
procedure shall be used to verify the result.
#
= Due to the insufficient sample area, reduced total sample
surface of 10 cm2 was used and the dilution factor was
adjusted accordingly.
Tested Components
(1) Black Plastic (A)
(2) Silvery Metal (B)
(3) Silvery Plating (B)
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Jan 27, 2010
: Jan 29, 2010 to Feb 01, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
(Ⅲ) Test Method:
Testing Item
Testing Method
Reporting Limit
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Cadmium (Cd) content
2 ppm
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Lead (Pb) content
2 ppm
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
Mercury (Hg) content
2 ppm
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
Chromium VI (Cr6+) content edition 1.0:2008 in annex C, by
1 ppm
(for non-metal material) alkaline digestion and determined
by UV-Vis spectrophotometer.
With reference to IEC 62321
6+
Chromium VI (Cr ) content edition 1.0:2008 in annex B, by
0.02
(by boiling water
boiling water extraction and
extraction on metal)
mg/kg with 50cm2
determined by UV-Vis
(mg/kg with 50cm2)
spectrophotometer.
With reference to IEC 62321
edition 1.0:2008 in annex A, by
Polybrominated Biphenyls solvent extraction and
5 ppm
(PBBs)
determined by GC-MSD and further
HPLC confirmation when
necessary.
With reference to IEC 62321
edition 1.0:2008 in annex A, by
Polybrominated Diphenyl
solvent extraction and
5 ppm
Ethers (PBDEs)
determined by GC-MSD and further
HPLC confirmation when
necessary.
With reference to EN 14582:2007
by combustion flask with oxygen
Halogen Content
50 ppm
and determined by ion
chromatography
Remark: Reporting Limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents
Reference Standard: IEC 62321 edition 1.0:2008
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard:EN 14582
sampling/grinding or
cutting
add absorbent in a
combustion flask &
place weighed sample in
equipment
fill the combustion
flask with oxygen
ignite then leave the
flask at room
temperature
transfer the absorbent
into a volumetric flask
make up with deionized
water
analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00146740
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401