2D-XNS

2D-XS Series
FIXED INPUT,ISOLATED&UNREGULATED Twin Output DC∕DC Converter
SELECTION GUIDE
Input
FEATURES
Output
Switching
Frequency
(KHz,Typ)
Nominal
Range
Max
Min
2D050505XS
5
4.5-5.5
5
200
20
80
84
2D050909XS
5
4.5-5.5
9
111
12
82
81
2D051212XS
5
4.5-5.5
12
83
9
82
82
2D051515XS
5
4.5-5.5
15
67
7
83
83
2D120505XS
12
10.8-13
5
200
20
80
180
Voltage(VDC)
Current
Efficiency
(%,Typ)
Voltage
(VDC)
Order code
◆
RoHS compliant
◆
Efficiency up to 85%
2D120909XS
12
10.8-13
9
111
12
83
150
2D121212XS
12
10.8-13
12
83
9
85
84
◆
SIP Package
2D121515XS
12
10.8-13
15
67
7
83
83
2D240505XS
24
21.6-26
5
200
20
81
82
2D240909XS
24
21.6-26
9
111
12
82
83
2D241212XS
24
21.6-26
12
83
9
84
83
2D241515XS
24
21.6-26
15
67
7
84
80
◆
Wide temperature performance at full 2 Watt
load,-40°C to 85 °C
◆
UL 94V-0 package material
◆
No heatsink required
◆
Low ripple and good EMC features
◆
Industry standard pinout
◆
Power sharing on output
◆
1KVDC isolation
◆
Continuous Short Circuit Protection
◆
Internal SMD construction
ISOLATION SPECIFICATIONS
Parameter
◆
No external components required
◆
Good dynamic feature
Isolation test voltage
Isolation resistance
Test conditions
Min.
Typ.
Max.
Unit
Flash tested for 1 minute and 1mA max(Vin/Vout)
1000
VDC
Flash tested for 1 minute and 1mA max(V01/V02)
1000
VDC
Test at Viso=500VDC(Vin/Vout)
1000
MΩ
Test at Viso=500VDC(V01/V02)
1000
Isolation capacitance
MΩ
(Vin/Vout)
90
PF
(V01/V02)
90
PF
MODEL SELECTION
2D①05②05③05④X⑤ S⑥
①Product Series
③Output Voltage1
⑤Fixed Input
②Input Voltage
④Output Voltage2
⑥SIP Package
APPLICATIONS
The 2D-XS series are specially designed for
applications where a group of polar power supplies are
isolated from the input power supply in a distributed
power supply system on a circuit board.
These products apply to:
1) where the voltage of the input power supply is fixed
(voltage variation ≤±10%);
2) where isolation is necessary between input and
output (isolation voltage ≤1000VDC);
3) where the regulation of the output voltage and the
output ripple noise are not demanded.
Such as: purely digital circuits,ordinary low frequency
analog circuits,and 1GBT power device driving circuits.
OUTPUT SPECIFICATIONS
Parameter
Test conditions
Min
Typ.
Output power
Line regulation
Load regulation
For Vin change of ±1%
Max
Unit
2
W
±1.2
10% to 100% full load(5V output)
12.8
15
10% to 100% full load(9V output)
8.3
10
10% to 100% full load(12V output)
6.8
10
10% to 100% full load(15V output)
6.3
10
Output voltage accuracy
%
See tolerance envelope graph
Temperature drift
100% full load
Output Ripple&Noise*
20MHz Bandwidth
100
0.03
Switching frequency
Full load,nominal input
70
%/°C
150
MV p-p
Khz
* Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC R ESERVES THE COPYRIGHT
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
2D-XS Series
COMMON SPECIFICATIONS
Parameter
Conditions
Min.
Typ.
Storage humidity range
Operating temperature
-40
Storage temperature
Lead temperature
Units
95
%
85
-55
1.5mm from case for 10 seconds
Max.
Filtering
To get the input/output ripple,an "LC"filtering network may be connected to
the input and output ends of the DC/DC converter.Which may produce a more
significant filtering effect.It should also be noted that the inductance and the
frequency of the "LC"filtering network should be staggered with the DC/DC
frequency to avoid mutual interference see (Figure 1).
125
℃
300
Temp.rise at full load
15
25
Cooling
Free air convection
Case material
Plastic(UL94-V0)
Short circuit protection*
Continuous
1
MTBF
3500
Weight
s
K hours
2.8
*Supply voltage must be discontinued at the end of short circuit duration.
g
In some circuits which are sensitive to noise and ripple.a filtering capacitor
may be added to the DC/DC output end and input end to reduce the noise and
ripple. However, the capacitance of the output filter capacitor must be proper.
If the capacitance is too big, a startup problem might arise. For every channel
of output, provided the safe and reliable operation is ensured, the
greatest capacitance of its filter capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Vin
Cin
Vout
Cout
TYPICAL CHARACTERISTICS
(VDC)
5
12
24
--
Temperature Derating Graph
(μF)
47
2.2
1.0
--
(VDC)
5
9
12
15
(μF)
4.7
2.2
1.0
0.47
It's not recommend to connect any external capacitor in the application field
with less than 0.5 watt output.
Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and
over-current protection is a linear voltage regulator with overheat protection
that is conn ect ed to the inp ut or outp ut end in ser i es (F i gu r e 2) .
OUTLINE DIMENSIONS & PIN CONNECTIONS
SIZE Graph
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
FOOTPRINT DETAILS
Pin
1
2
4
Note:
Unit:mm(inch)
Pin section:0.50*0.3mm(0.020*0.012inch)
Pin section tolerances: 0.10mm( 0.004inch)
General tolerances: ±0.25mm(±0.010inch)
5
6
7
Function
VIN
GND
+V01
0V1
+V02
0V2
When the environment temperature is higher than 71°C, the
product output power should be less than 60% of the
rated power.
No parallel connection or plug and play.
Requirement on output load
To ensure this module can operate efficiently and reliably, a minimum load is specified for this kind of DC/DC
converter in addition to a maximum load(namely full load).During operation, make sure the specified range
of input voltage is not exceeded,the minimum output load is not less than 10% of the full load, and that this
product should never be operated under no load!
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
E-mail:[email protected]
Website:http://www.microdc.cn
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 2