Specifications Download

[ UTZ-SC0334_3 ]
2013/10/16
Ultra Violet Laser Diode
NDU4316E
Engineering Sample

Features
Outline Dimension
• Optical Output Power: CW120mW
• Peak Wavelength: 390-400nm
• Can Type:5.6 Floating Mounted with Photo Diode and Zener Diode
Unit (mm)
1.
6)
(
(90°)
Emitting Point
mW
mA
V
C
C
0.25±0.03
0.4±0.1
1.0±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Glass Thickness
Ir (LD)
Vr (PD)
Tstg
Tc
Unit
Emitting Point
Reference Plane
(1.3)
Po
Absolute Maximum
Ratings
140
85
5
-40 ~ 85
-10 ~ 30
1.2±0.1
2.3±0.2
Symbol
(0.4)
6.5±1.0
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
0
+ .03
0
6 5.
Absolute Maximum Ratings
Item

Φ

Φ
4×Φ 0.43±0.08
Initial Electrical/Optical Characteristics
(Tc=25C)
Item
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Parallel
Beam
Divergence* Perpendicular
Parallel
Beam Pointing
Accuracy
Perpendicular
Monitor Current**
CW
Po=120mW
CW
Po=120mW
CW
Po=120mW
Po
p
Ith
Iop

Vop
//

//

Im
390
1.3
7.0
13.0
-2.0
-2.5
-
28
100
1.7
4.5
-
120
400
50
150
2.1
5.5
12.0
28.0
2.0
2.5
1.0
mW
nm
mA
mA
W/A
V




mA
Po=120mW
Po=120mW
Po=120mW
3
X+
1
2
4
Φ 2.0±0.2
Y+
( ) are reference figures
Pin Connection
This model has a Zener Diode built in
as a protection circuit against static
electricity.
* Full angle at 50% from peak intensity
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damage the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ UTZ-SC0334_3 ]
2013/10/16

Typical Characteristics

Forward Voltage vs. Forward Current
7
120
Tc=0ºC
100
Tc=25ºC
Forward Voltage [V]
Optical Output Power [mW]
Optical Output Power vs. Forward Current
140
80
60
40
20
0
6
5
4
3
2
Tc=0ºC
1
Tc=25ºC
0
0
20
40
60
80 100 120
Forward Current [mA]
140
0
Threshold Current vs. Case Temperature
40
60
80 100
Forward Current [mA]
120
140
Peak Wavelength vs. Case Temperature
45
404
40
Peak Wavelength [nm]
Threshold Current [mA]
20
35
30
25
20
15
402
400
398
396
394
392
390
388
-10
0
10
20
Case Temperature [ºC]
30
-10
0
10
20
Case Temperature [ºC]
Far Field Pattern
30
Typical Spectrum
Relative Optical Intensity
Relative Optical Intensity
θ//
θ⊥
-40
-30
-20
-10
0
10
20
30
40
393
394
395
396
Wavelength [nm]
Angle [°]




-2-
397
398
[ UTZ-SC0334_3 ]
2013/10/16

Cautions
(1) Operating method
 The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the
LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use
of APC (Automatic Power Control) is recommended, which use feedback of the optical output power to adjust the operation
current.
 Confirm that the optical output power generated by spike current when switching on and off does not exceed the maximum
absolute rating. Also, employ appropriate countermeasures to reduce chattering and/or overshooting in the Circuit.
(2) Static Electricity
 Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
 Active layer of LDs shall have high current density and generate high electric field during its operation. In order to
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
(4) Others
 Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,
communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance
for information on the applications in which exceptional quality and reliability are required, particularly when the failure or
malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters,
nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices).
 The Purchaser must acknowledge that any LD can statistically fail and must design its equipments in a fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs
of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
 Nichia prohibits Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
 The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
 No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
 This LD contains the one of candidate substance of SVHC (Substance of Very High Concern) specified in REACH
(Regulation, Evaluation, Authorization and Restriction of Chemicals) regulation. Nichia reports following
information on the basis of Article 33 (Duty to communicate information on substances in articles) in REACH.
Model number : NDU4316E
Affected component : Sealing glass
Substance name : Lead titanium trioxide , CAS number : 12060-00-3
Content : 0.2% to 0.3% per product
-3-