Specifications Download

[ UTZ-SC0338_2 ]
2013/01/09
Violet Laser Diode
NDV4316

Features
Outline Dimension
1.
6)
0
+ .0 3
0
6 5.
(
Unit (mm)
Φ
• Optical Output Power: CW120mW
• Peak Wavelength: 405nm
• Can Type:5.6 Floating Mounted with Photo Diode and Zener Diode
Φ
(90°)
Emitting Point
(0.4)
0.4±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
0.25±0.03
mW
mA
V
C
C
1.0±0.1
Glass Thickness
Ir (LD)
Vr (PD)
Tstg
Tc
Unit
Emitting Point
Reference Plane
(1.3)
Po
Optical Output Power (Tc=25C)
Allowable Reverse Current
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
Absolute Maximum
Ratings
140
85
5
-40 ~ 85
-10 ~ 70
1.2±0.1
2.3±0.2
Symbol
6.5±1.0
Absolute Maximum Ratings
Item

4×Φ 0.43±0.08
Initial Electrical/Optical Characteristics
Item
Condition
Symbol
(Tc=25C)
Min
Typ.
Max
Unit
3
X+
1
2
Optical Output Power
CW
Po
120
mW
4
Φ 2.0±0.2
Peak Wavelength
Po=120mW
400
405
410
nm
p
Y+
( ) are reference figure
Threshold Current
CW
Ith
35
50
mA
Operating Current
Po=120mW
Iop
120
150
mA
Pin Connection
Slope Efficiency
CW
1.2
1.4
1.9
W/A

Operating Voltage
Po=120mW
Vop
4.8
5.5
V
Parallel
7.0
9.0
12.0
//

Beam
Po=120mW
Divergence* Perpendicular
15.0
19.5
23.0


Parallel
-2.0
2.0
//

Beam Pointing
Po=120mW
Accuracy
Perpendicular
-2.5
2.5


Monitor Current**
Po=120mW
Im
0.1
0.3
0.5
mA
This model has a Zener Diode built in
* Full angle at 50% from peak intensity
as a protection circuit against static
electricity.
** Monitor Current is short time power reference purpose only.
Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damage the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ UTZ-SC0338_2 ]
2013/01/09

Typical Characteristics


-2-
[ UTZ-SC0338_2 ]
2013/01/09

Cautions
(1) Operating method
 The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the
LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use
of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current.
 Confirm that the optical output power generated by spike current when switching on and off does not exceed the
maximum absolute rating. Also, employ appropriate countermeasures to reduce chattering and/or overshooting in
the Circuit.
(2) Static Electricity
 Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
 Active layer of LDs shall have high current density and generate high electric field during its operation. In order to
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
(4) Others
 Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,
communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance
for information on the applications in which exceptional quality and reliability are required, particularly when the failure or
malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters,
nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices).
 The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior
to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and
provides the features required by the Circuit and any related modules, equipment and/or systems.
 Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
 The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
 No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-