Specifications Download

[ YTB-SC0014-03 ]
2012/10/16
Blue Laser Diode for External Cavity
NDBA116T
Test Sample

Features
• For External Cavity Laser with Low Reflection Coating on front facet
• Optical Output Power: 30mW (Pulse)
• Can Type: 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Absolute Maximum Ratings
(Pulse *1)
Absolute Maximum
Item
Symbol
Unit
Ratings
Optical Output Power
Po
45
mW
LD Forward Current
If
280
mA
Allowable Reverse Current
Ir (LD)
85
mA
PD Reverse Voltage
Vr (PD)
20
V
Storage Temperature
Tstg
-25 ~ 75
C
Operating Case Temperature
Tc
10 ~ 30
C
*Pulse Condition: Pulse Width 2.5μs, Duty 5%
Initial Electrical/Optical Characteristics
Item
Optical Output Power
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Condition
Pulse
Po=30mW
Pulse
Po=30mW
Pulse
Po=30mW
Beam Divergence*3
Po=30mW
Symbol
Po
p
Ith
Iop

Vop
//

//
Min
450
7
15
-2.0
(Pulse*1 Ta=23C *2)
Typ.
Max
Unit
30
mW
455
nm
210
mA
230
mA
1.5
W/A
7.1
V
12
deg.
25
deg.
2.0
deg.
Outline Dimension
Unit (mm)
( ) are reference figures
Pin Connection
Emission
Point
Angle
Po=30mW

-3.0
3.0
deg.
Accuracy
Monitor Current*4
Po=30mW
Im
1
mA
*1 The Laser can NOT be lasing under CW operating without External Cavity. Pulse 0.5μs,
Duty 20%
This model has a zener diode built in
*2 There is some range in ambient temperature. *3 Full angle at 50% from peak intensity.
as protection circuit against static
*4 Monitor Current is short time power reference purpose only. Not guaranteed for electricity.
accuracy. This value must be affected intensely by feedback from composing optics.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
Diffractive feedback efficiency to the Laser diode must be limited less than 30 % under the External cavity configuration.
This model can only be performed under CW operating with External Cavity.
This model is Test Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ YTB-SC0014-03 ]
2012/10/16
Typical Initial Electrical/Optical Characteristics
Forward Voltage vs. Forward Current (Pulse)
Optical Output Power vs. Forward Current (Pulse)
8
5
50
4
30
3
2
20
Po
1
SE
Forward Voltage Vf [V]
40
10
Ta=23deg.C
7
Slope Efficiency SE [-]
Optical Output Power Po [mW]
Ta=23deg.C
6
5
4
3
2
1
0
300
0
0
100
200
0
0
100
Current[mA]
Spectrum (Pulse)
1
25
Ta=23deg.C
Po=30mW
θ∥
Optical Intensity [5dB/div] .
Optical Intensity [-] .
θ⊥
0.5
-20
-10
0
10
20
30
20
40
Ta=23deg.C
Po=30mW
15
10
5
0
448
0
-30
300
Forward Current If [mA]
Far Field Pattern (Pulse)
-40
200
450
452
454
Wavelength [nm]
Angle θ [°]
-2-
456
458
[ YTB-SC0014-03 ]
2012/10/16
Cautions
(1) Operating method
 The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,
the LD will require more operation current to maintain same output power as it degrades.
 The use of heat sink is strongly recommended to reduce increases in temperature.
 Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering
and/or overshooting in the Circuit.
(2) Static Electricity
 Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
 Active layer of LDs shall have high current density and generate high electric field during its operation.
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
In order to
(4) Others
 Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales
staff in advance for information on the applications in which exceptional quality and reliability are required,
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support
systems and safety devices).
 The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
 Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
 The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
 No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-