NICHIA NDVA111T

[ YTB-SC0018-01]
2012/10/12
Violet Laser Diode for External Cavity
NDVA111T
Test Sample
Features
Outline Dimension
• For External Cavity Laser with Low Reflection Coating on front facet
• Optical Output Power: 45mW
• Can Type: φ 5.6 mm Cathode Ground
Unit (mm)
Φ5
)
.6
1
.6
- +0
0.0
3
Φ
(
(90°)
Absolute Maximum Ratings
Item
Symbol
Optical Output Power
LD Forward Current
LD Reverse Voltage
Storage Temperature
Operating Case Temperature
Po
If
Vr (LD)
Tstg
Tc
Absolute Maximum
Ratings
65
120
2
-25 ~ 75
10 ~ 55
Initial Electrical/Optical Characteristics
Emitting Point
(0.4)
Unit
.10
±
4.
0
mW
mA
V
°C
°C
1.0±0.1
ss
Φ
Φ 3.55±0.1
.20
±
3.
1. 2
0
±
2.
1
0.
1
±
5.
6
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
CW
Po
-
-
45
mW
Peak Wavelength
Po=45mW
λp
400
-
410
nm
Threshold Current
CW
Ith
-
50
-
mA
Operating Current
Po=45mW
Iop
-
72
-
mA
Slope Efficiency
CW
η
-
1.8
-
W/A
Operating Voltage
Po=45mW
Vop
-
4.3
-
V
Beam Divergence*2
Po=45mW
θ//
7
-
12
deg.
G
Emitting Point
Reference Plane
)
3
.
1
(
Φ 0.45±0.1
3×
(Ta=23°C *1)
Item
en
3
.0
0 kic
hT
±
5
s
.2
0 sla
Z+
4.2±0.2
3
X+
1
2
Y+
Φ 2.0±0.2
( ) are reference figures
Pin Connection
2
1
LD
15
23
deg.
θ⊥
1. LD Anode
Emission
2. NC
-2.0
2.0
deg.
∆θ//
Angle
Po=45mW
Point
3. LD Cathode
3
-2.5
2.5
deg.
∆θ⊥
Accuracy
This model does not have Photo Diode.
*1 There is some range in ambient temperature.
*2 Full angle at 50% from peak intensity
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
Diffractive feedback efficiency to the Laser diode must be limited less than 20 % under the External cavity configuration.
This model is Test Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ YTB-SC0018-01]
2012/10/12
Typical Initial Electrical/Optical Characteristics
Optical Output Power vs. Forward Current
Forward Voltage vs. Forward Current
50
5
5
Ta=23deg.C
4.5
Slope Efficiency SE [-]
4
3.5
30
3
2.5
20
2
1.5
10
Forward Voltage Vf [V]
40
1
Po
SE
40
60
3
2
1
0
20
4
0.5
0
0
80
0
20
Forward Current If [mA]
40
60
80
Forward Current If [mA]
Spectrum
Far Field Pattern
1
10
Ta=23deg.C
Po=45mW
0
Optical Intensity [dB]
Optical Intensity [-] .
Optical Output Power Po [mW]
Ta=23deg.C
0.5
Ta=23deg.C
Po=45mW
-10
-20
-30
-40
-50
0
-30
-20
-10
0
10
20
30
-60
399
400
401
402
403
Wavelength [nm]
Angle θ [°]
-2-
404
405
406
[ YTB-SC0018-01]
2012/10/12
Cautions
(1) Operating method
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,
the LD will require more operation current to maintain same output power as it degrades.
The use of heat sink is strongly recommended to reduce increases in temperature.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering
and/or overshooting in the Circuit.
(2) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
Active layer of LDs shall have high current density and generate high electric field during its operation.
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
In order to
(4) Others
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales
staff in advance for information on the applications in which exceptional quality and reliability are required,
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support
systems and safety devices).
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-