pdf

www.osram.com
LINEARlight Colormix Power – LR18CP
Preliminary Datasheet
Benefits
 Broad portfolio (Eco, Advanced, Power) with the same form
factor offering high variety in luminous flux and color
temperatures while being simply exchangeable
 Modules can be joined together in series to make seamless
strip lighting, without any further accessory
 Intermateable with LINEARlight Colormix Advanced & Eco
 Low maintenance costs thanks to a life of up to 50k hours
Application
 Dynamic color application
 Background lighting
 Coves lightning with dinamic color effects
Technical Operating Data
Product
Color
Number of
Voltage
Current
LEDs
[V]*
[A]*
Power
Radiance
max. [W]* Angle [°]*
Wavelength
Lum. Flux
[nm]*
[lm]
LR18CP-RGB
Red
6
24
0,34
8.4
150
616
246
LR18CP-RGB
Green
6
24
0,27
7.6
150
531
481
LR18CP-RGB
Blue
6
24
0,12
3.1
150
468
67
LR18CP-RGB
White
18
24
0,73
19.1
150
---
794
*) Preliminary Data
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data
Technical Features
 Metal core PCB equipped with18 OSLON RGB LED
 Seamless concept with up to 3 modules in series
 Typical luminous flux 1417 lm/m
 Lifetime 50.000 h @L70 @tcmax 65°C
 SMD-4 plug connector (male/female) on both
 Operation only with control gears 24 V
(see page 2 for recommendations)
sides of the PCB
 Feeder and cable (CONNECTsystem LR-4x)
 With optional accessory upgrade to individual
d l possible
ibl ((see page 4)
overallll modules
availible (see page 4)
 Mounting holes (Ø 3.2mm) for simple fixing
LINEARlight Colormix Power LR18CP
12.11.2012
Page 1 of 4
www.osram.com
Minimum and Maximum Ratings
Product
Operating Temperature
Storage Temperature
[C°]*
Voltage Range
Reverse Voltage
at Tc-Point [C°]*
[V dc]*
[V dc]*
-30 … 65
-30 … 90
23 … 25
25
LR18CP-RGB
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a
temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below.
Drawing
R
D
l3
l2
Tc
l
560 mm
b
20 mm
h
2 mm
l1
31 mm
l2
217,8
l3
217,8
R
1,4+0,2 mm
D
3.2 mm
Driver
OPTOTRONIC control gears
Product name
LINEARlight
Colormix Power
Power
19.1 W
OT20
OT75
OT24
OT80
220-240 / 24
220-240 / 24
220-240 / 24 DIM P
220-240 / 24 DIM P
1 Module
3 Modules
1 Module
3 Modules
Light Management Systems
Product name
LINEARlight
Colormix Power
Power
OTi DALI 75
OT EASY 60
19.1 W
3 Modules
3 Modules
LINEARlight Colormix Power LR18CP
12.11.2012
OT RGB
DIM
3x2
Modules
OT DMX
RGB DIM
OT DMX 3x1
RGB DIM
3x2 Modules
3x1 Modules
Page 2 of 4
www.osram.com
Sicherheitshinweise
 The LED module itself and all its components must not be mechanically stressed.
 The mounting of the module has to be done on a metal heat sink. As accessories
(see order numbers page 4) are verified linear LINEARlight Track listed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the
intended substrate.
substrate Heavy vibration should be avoided.
avoided
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark
and be ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent
p
authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information").
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical
and safety standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be
destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2).
 Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not
recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to ESD steps when mounting the module.
 Asymmetrical voltage drops can cause a strong overload and destruction of single modules.
 Use only CONNECTsystem for electrical installation. Three types of connectors are available: LR-4PIN Feeder with 500 mm cable length. LR-4CONN-45 - Connector for through wiring with 45 mm cable length.
LR-4CONN-250 - Connector for through wiring with 250 mm cable length.
 The LED module can typically survive levels of up to 4 Amperes. As a general design precaution, if the
maximum output current of th power supply is more than 4 Amperes, fast-blow fuses should be incorporated
into the wiring plan.
 Electrical contact is achieved with the contact cables. A maximum number of 3 modules can be installed
consecutively from one power feed
feed. Operation with more than 3 consecutive modules will reduce photometric
performance and exceed the current carrying capacity of the module.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against
corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide
suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
LINEARlight Colormix Power LR18CP
12.11.2012
Page 3 of 4
www.osram.com
Montagehinweise
 The mounting of the module has to be done on a metal heat sink
 In order to optimize the thermal management the metal surface needs to be clean (dirt and oil free) and
planar for the best contact with the LED module.
 To connect one module, the feeder LR-4PIN-500 must be plugged in the "INPUT" side of the module.
Ordering Number
Product group
Product
EAN*
LINEARlight Colormix POWER
LR18CP-RGB
4008321 971593
8
CONNECTsystem feeder
LR-4PIN-500
4008321 971852
16
CONNECTsystem
LR-4CONN-45
4008321 971814
16
CONNECTsystem
LR-4CONN-250
4008321 994400
16
LINEARlight Track
LT-280
4008321 975966
8
LINEARlight Track
LT-560
4008321 975980
8
LINEARlight Track end caps
LT-ENDCAP
4008321 976109
16
LINEARlight Track Mounting bracket
LT-MB
4008321 994424
16
Optic Tray
OTR-280-LR21P
4008321 976086
8
Optic 30°
OPLR1x1-30
4008321 976000
140
Optic 70°
OPLR1x1-70
4008321 976024
140
Optic 20°x 50°
OPLR1x1-20x50
4008321 976048
140
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
LINEARlight Colormix Power LR18CP
12.11.2012
Page 4 of 4
S-Unit*