Touch DIM PD LI 2P WOS Motion sensor w/o sensor head General Safety information • This product may only be installed by qualified personnel who have been appropriately trained and who have the relevant authority. The installation personnel must be familiar with the operating instructions. Power must be switched off before any work is undertaken on the unit. • The relevant safety and accident prevention regulations must be observed. • This product is designed exclusively for control of electronic ballasts from OSRAM type QUICKTRONIC INTELLIGENT DALI (QTi DALI...DIM) or HALOTRONIC INTELLIGENT DALI (HTi DALI..DIM). Other usage may destroy this and other connected products. • No other control components may be connected. • Max. number of ballasts and max. wire length has to be observed. • Connection to other voltage levels will destroy the device. • The product has to be supplied by an AC voltage (no DC allowed). This has to be respected especially when a UPS system is used. • ATTENTION!: The motion sensor element is connected to mains, a sufficient isolation and protection against contact has to be guaranteed. The sensor cable and the PIR sensor socket apply to low voltage installation regulations of 230V AC. If isolation parts or the plastic cab of the motion sensor element is damaged, the device has to be put out of operation. OSRAM GmbH Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 Page 1 OSRAM - operating instructions: TOUCH DIM PD LI 2P WOS Wiring diagram L N PE ~ ~ DA Push button (manual control) 1 ECG QTi DALI DA L N S ~ ~ DA ~ ~ DA 3 4 Lamp 1 ECG QTi DALI DA TOUCH DIM Sensor 2 2 3 4 Lamp 1 ECG QTi DALI DA 2 3 4 max. 4 QTi ECG or HTi transform ers Lamp signal wire length max. 10m Push button and sensor have to be connected to the same mains phase! ~ ~ DA DA 1 ECG QTi DALI 2 3 4 Lamp Mounting hints The sensor is connected to a 3 wire cable which is admitted for mains voltage. Parallel connection of several sensors is not allowed. The sensor is typically installed in luminaires, ceiling installation is possible by use of a flush device box and an adequate cover. Following sensor heads are approved to be used with the Touch DIM PD LI 2P WOS sensor: (-> sensor head not included in delivery) PANASONIC NaPiOn sensors (passiv infrared) Digital version - Standard type (5m range) Standard Economy - Type for small movements Standard Economy - Spot type Standard Economy - 10m type Standard Economy anthracite white anthrazit white AMN11111 AMN11112 AMN31111 AMN31112 anthracite white anthracite white AMN12111 AMN12112 AMN32111 AMN32112 anthracite white anthracite white AMN13111 AMN13112 AMN33111 AMN33112 anthracite white anthracite white AMN14111 AMN14112 AMN34111 AMN34112 When adding a sensor head to the sensor, please note the following: • The entire workplace must lie within the monitoring cone of the sensor. • The sensor must not be exposed to drafts (e.g. near air vents). A draft could be misinterpreted as the presence of a person in the room. Page 2 OSRAM - operating instructions: TOUCH DIM PD LI 2P WOS Technical data Designation: Operating voltage: Connections : Interface : overall length of signal connection: Power consumption : Operating temperature: CE requirement: Protection class: Protection type: Touch DIM PD LI 2P WOS Motion sensor w/o sensor head 220 – 240V / 50-60Hz (no DC operation) L, N, S (signal) OSRAM specific, max. 4 QTi DALI ECG or. 4 HTi transformers connectable 10m < 0.5 W 0C°...+ 50C° EMC according to EN 61547 II IP 20 OSRAM GmbH Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 ZNN2587707-000-00_B Page 3 OSRAM - operating instructions: TOUCH DIM PD LI 2P WOS