TO-94 20150714

Test Report.
No. CANEC1511676703
Date: 14 Jul 2015 .
Page 1 of 5.
HANGZHOU SILAN MICROELECTRONICS CO.,LTD .
NO.4 HUANGGUSHAN ROAD,HANGZHOU,ZHEJIANG
CHINA.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : TO-94 .
SGS Job No. :
CP15-038471 - GZ .
Tested Sample Info. : .
SA276.
Client Ref. Info. : .
SA276/SD1579 .
Date of Sample Received : .
08 Jul 2015.
Testing Period : .
08 Jul 2015 - 13 Jul 2015 .
Test Requested : .
Selected test(s) as requested by client. .
Test Method : .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Conclusion :.
Based on the performed tests on submitted sample(s), the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs),
Polybrominated diphenyl ethers (PBDEs) comply with the limits as set by RoHS
Directive 2011/65/EU Annex II; recasting 2002/95/EC. .
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Echo Yeung.
Approved Signatory .
Kenny Wang.
Approved Signatory .
Test Report.
No. CANEC1511676703
Date: 14 Jul 2015 .
Page 2 of 5.
Test Results :.
Test Part Description : .
Specimen No..
SN1.
SGS Sample ID.
CAN15-116767.004
Description.
Black body w/ brown printing .
SN2.
CAN15-116767.005
Silvery metal pin .
Remarks :.
(1) 1 mg/kg = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5)With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS. .
Test Item(s).
Cadmium (Cd) .
Limit.
Unit.
MDL.
004.
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
10
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (CrVI) .
1,000
mg/kg.
2
ND
Sum of PBBs .
1,000
mg/kg.
5
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
Decabromobiphenyl .
-
mg/kg.
5
ND
1,000
mg/kg.
5
ND
Sum of PBDEs .
Test Report.
No. CANEC1511676703
Date: 14 Jul 2015 .
Limit.
Unit.
MDL.
004.
Monobromodiphenyl ether .
-
mg/kg.
5
ND
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Test Item(s).
Page 3 of 5.
Notes :.
(1) The maximum permissible limit is quoted from directive 2011/65/EU, Annex II. .
RoHS Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by spot test /
Colorimetric Method using UV-Vis. .
Test Item(s).
Limit.
Unit.
MDL.
005.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
20
Mercury (Hg).
1,000
mg/kg.
2
ND
-
-
♢
Negative
Hexavalent Chromium (CrVI) .
Notes :.
(1) The maximum permissible limit is quoted from directive 2011/65/EU, Annex II.
(2)◇Spot-test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result is
Negative or cannot be confirmed.)
◇Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is
equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
Information on storage conditions and production date of the tested sample is unavailable and thus results
of Cr(VI) represent status of the sample at the time of testing. .
Test Report.
No. CANEC1511676703
Date: 14 Jul 2015 .
Page 4 of 5.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Bruce Xiao / Sunny Hu
2) Name of the person in charge of testing: Bella Wang / Cutey Yu
3) These samples were dissolved totally by pre -conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded ).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
Residue
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
Cr6+
PBBs/PBDEs
GC-MS
DATA
Nonmetallic
material
Adding digestion
reagent
Heating to
90~95℃ for
extraction
Filtration and
pH adjustment
Adding 1,5diphenylcarbazide
for color
development
Metallic
material
Positive
Spot test
Negative
Boiling water
extraction
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
A red color
indicates the
presence of Cr 6+. If
necessary , confirm
with UV-Vis.
DATA
DATA
Test Report.
No. CANEC1511676703
Date: 14 Jul 2015 .
Sample photo: .
CANEC1511676703
CAN15-116767.004 .
CANEC1511676703
CAN15-116767.005 .
SGS authenticate the photo on original report only .
*** End of Report *** .
Page 5 of 5.