SERIES: VHE100W │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
up to 100 W isolated output
industry standard half brick package
4:1 input range (9~36 V, 18~75 V)
single output from 3.3~48 V
1,500 V isolation
tantalum free capacitors used
over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• very high efficiency up to 93%
RoHS
MODEL
input
voltage
output
voltage
output
current
output
power
ripple and
noise1
efficiency
range
(Vdc)
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VHE100W-Q24-S3R3
9 ~ 36
3.3
25
82.5
100
87
VHE100W-Q24-S5
9 ~ 36
5
20
100
100
89.5
VHE100W-Q24-S12
9 ~ 36
12
8.4
100
120
90.5
VHE100W-Q24-S15
9 ~ 36
15
6.7
100
120
90.5
VHE100W-Q24-S24
9 ~ 36
24
4.2
100
240
89
VHE100W-Q24-S48
9 ~ 36
48
2.1
100
480
88.5
VHE100W-Q48-S3R3
18 ~ 75
3.3
25
82.5
100
88
VHE100W-Q48-S5
18 ~ 75
5
20
100
100
92
VHE100W-Q48-S12
18 ~ 75
12
8.4
100
120
93
VHE100W-Q48-S15
18 ~ 75
15
6.7
100
120
92.5
VHE100W-Q48-S24
18 ~ 75
24
4.2
100
240
91
VHE100W-Q48-S48
18 ~ 75
48
2.1
100
480
90.5
Notes:
1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output
PART NUMBER KEY
VHE100W - QXX - SXXX X
Base Number
Input Voltage
Output Voltage
cui.com
Remote On/Off Control
"blank" = positive logic
N = negative logic
For more information, please visit the product page.
CUI Inc │ SERIES: VHE100W │ DESCRIPTION: DC-DC CONVERTER
date 02/14/2013 │ page 2 of 4
INPUT
parameter
conditions/description
operating input voltage
24 V input
48 V input
surge voltage
100 ms max.
under voltage lockout
power up
power down
min
typ
max
units
9
18
24
48
36
75
Vdc
Vdc
50
100
Vdc
Vdc
24 V input
48 V input
24
48
24
48
V
V
V
V
input
input
input
input
8.8
17
8
16
Vdc
Vdc
Vdc
Vdc
positive logic remote on/off1
filter
Notes:
PI type
1. logic compatibility, open collector ref to -input
Module ON, 3.5 ~ 75 Vdc or open circuit
Module OFF, <1.2 Vdc
2. negative logic remote on/off available
Module ON, <1.2 Vdc current limit, 110~165% nominal output
Module OFF, 3.5 ~ 75 Vdc or open circuit
OUTPUT
parameter
conditions/description
max
units
line regulation
measured from high line to low line
min
typ
±0.2
%
load regulation
measured from full load to zero load
±0.2
%
±1.5
%
500
µs
voltage accuracy
transient response
25% step load change
adjustability
switching frequency
100% load, input voltage range
temperature coefficient
±10
%
250
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
max
units
over voltage protection
%Vo
115
140
%
short circuit protection
continuous
current limit
% nominal output current
110
140
%
thermal shutdown case temp.
typ
105
°C
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
input to case
output to case
min
isolation resistance
UL 60950-1, CE
RoHS compliant
yes
MTBF
MIL-STD-217F, GB, 25°C, full load
max
units
1,500
1,500
1,500
Vdc
Vdc
Vdc
10
MΩ
isolation capacitance
safety approvals
typ
1,000
pF
TBD
hours
ENVIRONMENTAL
parameter
max
units
case operating temperature
-40
105
°C
storage temperature
-55
105
°C
95
%
humidity
conditions/description
min
non-condensing
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: VHE100W │ DESCRIPTION: DC-DC CONVERTER
date 02/14/2013 │ page 3 of 4
DERATING CURVE
Load (%)
100
80
with heatsink
60
40
20
-40
-20
0
20
40
60
80
105
120
Ambient Temperature (°C)
MECHANICAL
parameter
conditions/description
min
dimensions
2.28 x 2.40 x 0.50 (57.9 x 61.0 x 12.7 mm)
case material
aluminum
typ
max
units
inch
weight
95
g
MECHANICAL DRAWING
units: inches[mm]
TOLERANCE:
inches: X.XX = ±0.02
X.XXX = ±0.010
mm: X.XX = ±0.5
X.XXX = ±0.25
0.10 min
[2.5]
Mounting Inserts
M3*0.5 Through 4pl.
[2.03]
0.50
[12.7]
5
3
6
[1.02]
4
0.600
[15.24]
1.400
[35.56]
2.00
[50.8]
2.40
[61.0]
Bottom View
PIN CONNECTIONS
7
2
8
1
9
0.48
[12.3]
1.90
[48.2]
2.28
[57.9]
cui.com
PIN
FUNCTION
1
+Vin
2
On/Off
3
CASE
4
-Vin
5
-Vo
6
-S
7
TRIM
8
+S
9
+Vo
For more information, please visit the product page.
CUI Inc │ SERIES: VHE100W │ DESCRIPTION: DC-DC CONVERTER
date 02/14/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
08/22/2012
1.01
added negative logic option to part number key
02/14/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.