VHB200W Datasheet - DC-DC CONVERTER | CUI Inc

For more information, please visit the product page.
date
04/01/2013
page
1 of 4
SERIES: VHB200W │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
up to 200 W isolated output
industry standard half brick package
4:1 input range (10~36 V, 18~75 V)
single output from 3.3~48 V
1,500 V isolation
over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• efficiency up to 89%
RoHS
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
range
(Vdc)
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VHB200W-Q24-S3R3
10 ~ 36
3.3
50
165
100
87
VHB200W-Q24-S5
10 ~ 36
5
40
200
100
87
VHB200W-Q24-S12
10 ~ 36
12
16.7
200
150
86
VHB200W-Q24-S15
10 ~ 36
15
13.3
200
150
86
VHB200W-Q24-S24
10 ~ 36
24
8.3
200
240
87
VHB200W-Q24-S28
10 ~ 36
28
7.1
200
280
87
VHB200W-Q24-S48
10 ~ 36
48
4.2
200
240
86
VHB200W-Q48-S3R3
18 ~ 75
3.3
40
132
100
88
VHB200W-Q48-S5
18 ~ 75
5
40
200
100
89
VHB200W-Q48-S12
18 ~ 75
12
16.7
200
150
88
VHB200W-Q48-S15
18 ~ 75
15
13.3
200
150
88
VHB200W-Q48-S24
18 ~ 75
24
8.3
200
240
88
VHB200W-Q48-S28
18 ~ 75
28
7.1
200
280
88
VHB200W-Q48-S48
18 ~ 75
48
4.2
200
240
87
Notes:
1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output
PART NUMBER KEY
VHB200W - QXX - SXX X
Base Number
Input Voltage
Output Voltage
cui.com
Remote On/Off Control
"blank" = positive logic
N = negative logic
For more information, please visit the product page.
CUI Inc │ SERIES: VHB200W │ DESCRIPTION: DC-DC CONVERTER
date 04/01/2013 │ page 2 of 4
INPUT
parameter
conditions/description
operating input voltage
under voltage lockout
power up
power down
24
48
24
48
V
V
V
V
min
typ
max
units
10
18
24
48
36
75
Vdc
Vdc
input
input
input
input
9.5
17
8.5
16
Vdc
Vdc
Vdc
Vdc
positive logic remote on/off1
filter
Notes:
PI type
1. logic compatibility, open collector ref to -input
Module ON, >3.5 Vdc or open circuit
Module OFF, <1.8 Vdc
OUTPUT
parameter
conditions/description
line regulation
load regulation
min
typ
max
units
measured from high line to low line
±0.2
%
measured from full load to zero load
±0.2
%
voltage accuracy
transient response
25% step load change
adjustability2
switching frequency
100% load, input voltage range
temperature coefficient
Notes:
±1.5
%
500
µs
±10
%
250
kHz
±0.03
%/°C
2. trim-up: connect a resistor between the trim pin and +Sense
trim-down: connect a resistor between the trim pin and -Sense
PROTECTIONS
parameter
conditions/description
min
over voltage protection
%Vo
115
short circuit protection
continuous
current limit
% nominal output current
typ
110
thermal shutdown case temp.
max
units
140
%
150
110
%
°C
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
input to case
output to case
min
typ
1,500
1,500
1,500
isolation resistance
MΩ
1,000
safety approvals
UL60950-1
RoHS compliant
yes
cui.com
units
Vdc
Vdc
Vdc
10
isolation capacitance
max
pF
For more information, please visit the product page.
CUI Inc │ SERIES: VHB200W │ DESCRIPTION: DC-DC CONVERTER
date 04/01/2013 │ page 3 of 4
ENVIRONMENTAL
parameter
conditions/description
min
case operating temperature
storage temperature
humidity
max
units
-40
typ
100
°C
-55
105
°C
95
%
max
units
non-condensing
MECHANICAL
parameter
conditions/description
dimensions
57.9 x 61.0 x 13.2 (2.28 x 2.40 x 0.52 inch)
min
case material
aluminum baseplate with plastic case
weight
typ
mm
114
g
MECHANICAL DRAWING
57.90 2.280
4.60 0.181
2.03 0.080
(4 PLCS)
50.80 2.000
(2 PLCS)
4
5
3
6
61.00 2.402
7
15.24 0.600
(2 PLCS)
M3x0.5 through
(4 PLCS)
Note:
2
8
1
9
35.56 1.400
(2 PLCS)
1.02 0.040
(5 PLCS)
48.25
BOTTOM VIEW
Bottom
View
All dimensions in mm(inches)
All specifications measured at 25°C, nominal input voltage, and full load unless otherwise noted.
cui.com
13.20 0.520
PIN CONNECTIONS
PIN
FUNCTION
1
+Vin
2
On/Off
3
CASE
4
-Vin
5
-Vo
6
-S
7
TRIM
8
+S
9
+Vo
For more information, please visit the product page.
CUI Inc │ SERIES: VHB200W │ DESCRIPTION: DC-DC CONVERTER
date 04/01/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
08/08/2008
1.01
new template applied
08/05/2011
1.02
add remote on/off control to the part number key
11/23/2011
1.03
features updated
12/20/2011
1.04
misc. updates and corrections
02/14/2012
1.05
V-Infinity branding removed
09/07/2012
1.06
updated spec
04/01/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to