Datasheet

G3VM-21UR@
MOS FET Relays
VSON package with Low Output Capacitance and ON Resistance type (Low C × R)
World's smallest New VSON Package
with Low Output Capacitance and
Low ON Resistance
• Load voltage 20V
RoHS Compliant
Note: The actual product is marked differently from the
image shown here.
Refer to "Common Precautions".
■Application Examples
• Semiconductor test equipment
• Communication equipment
• Test & measurement equipment
• Data loggers
■Package
■Model Number Legend
(Unit : mm, Average)
G 3 V M -@ @ @ @ @
2.45
1 2 3 4 5
1.3
1.45
Note: The actual product is marked differently
from the image shown here.
1. Load Voltage
2: 20V
3. Package type
U: VSON 4 pin
2. Contact form
1: 1a (SPST-NO)
4. Additional functions
R: Low On-resistance
5. Other informations
When specifications overlap,
serial code is added in the
recorded order.
■Ordering Information
Package type
VSON4
Contact form
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting
Terminals
Packing/Tape cut
Continuous
load current
(peak value) *
Model
200mA
G3VM-21UR10
450mA
G3VM-21UR1
1,000mA
G3VM-21UR11
20V
Packing/Tape & reel
Minimum
package
quantity
Model
Minimum
package
quantity
G3VM-21UR10(TR05)
1 pc.
G3VM-21UR1(TR05)
500 pcs.
G3VM-21UR11(TR05)
Note: When ordering tape packing, add "(TR05)" (500pcs/reel) to the model number.
Ask your OMRON representative for orders under 500 pcs. We can supply products with the tape already cut.
Tape-cut VSONs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
* The AC peak and DC value are given for the load voltage and continuous load current.
V
S
O
N
■Absolute Maximum Ratings (Ta = 25°C)
Item
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Output
G
3
V
M
I
2
1
U
R
@
Input
LED forward current
Continuous load current (AC peak/DC)
Symbol
G3VM-21UR10
G3VM-21UR1
G3VM-21UR11
Unit
IF
30
mA
ΔIF/°C
−0.3
mA/°C
VR
5
V
TJ
125
°C
VOFF
20
IO
450
1,000
mA
ΔIO/°C
−2
−4.5
−10
mA/°C
lop
0.6
1.3
3
A
Connection temperature
TJ
125
°C
Dielectric strength between I/O
(See note 1.)
VI-O
300
Vrms
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Ta≥25°C
V
200
Pulse ON current
ON current reduction rate
Measurement conditions
Ta
−40~+85
°C
Tstg
−40~+125
°C
−
260
°C
Ta≥25°C
t=100ms, Duty=1/10
AC for 1 min
With no icing or condensation
10s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side
and all pins as a group on the light-receiving side.
1
G3VM-21UR@
MOS FET Relays
■Electrical Characteristics (Ta = 25°C)
Item
Symbol
Output
Input
LED forward voltage
VF
G3VM-21UR10
G3VM-21UR1
Minimum
1.1
Typical
1.27
Maximum
1.4
G3VM-21UR11
Unit
Measurement conditions
V
IF=10mA
Reverse current
IR
Maximum
10
μA
VR=5V
Capacity between terminals
CT
Typical
30
pF
V=0, f=1MHz
mA
IO=100mA
Trigger LED forward current
IFT
Release LED forward current
IFC
Maximum resistance with output
ON
RON
Current leakage when the relay
is open
ILEAK
Capacity between terminals
COFF
Typical
1
−
0.6
Maximum
3
Minimum
0.1
mA
Typical
3
0.8
0.18
Maximum
5
1.2
0.22
Typical
0.8
5
40
Maximum
1.1
12
−
Maximum
Capacity between I/O terminals
CI-O
Typical
Insulation resistance between I/O
terminals
RI-O
Typical
Turn-ON time
tON
Turn-OFF time
tOFF
1
1
0.4
108
Typical
0.05
0.17
−
Maximum
0.2
0.4
2
Typical
Maximum
−
0.02
0.2
0.4
IOFF=10μA
Ω
IF=5mA, t<1s,
IO=Continuous load current ratings
nA
VOFF=20V
pF
V=0, f=100MHz, t<1s
pF
f=1MHz, VS=0V
MΩ
VI-O=500VDC, ROH≤60%
ms
IF=5mA, RL=200Ω,
VDD=10V (See note 2.)
1
Note: 2. Turn-ON and Turn-OFF Times
IF
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
90%
t ON
t OFF
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Item
Load voltage (AC peak/DC)
Operating LED forward current
Symbol
VDD
IF
Continuous load current (AC peak/DC)
IO
Ambient operating temperature
Ta
G3VM-21UR10
G3VM-21UR1
Maximum
16
Minimum
5
Typical
7.5
Maximum
20
Maximum
200
450
Minimum
−20
Maximum
65
G3VM-21UR11
Unit
V
mA
1,000
°C
V
S
O
N
G
3
V
M
I
2
1
U
R
@
2
G3VM-21UR@
MOS FET Relays
■Engineering Data
zContinuous load current vs.
Ambient temperature
(Maximum value)
30
25
20
15
10
5
0
-40
-20
0
20
40
60
80
IO - Ta
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
35
G3VM-21UR11
1000
800
600
G3VM-21UR1
400
-20
0
20
40
60
80
0
G3VM-21UR10
-0.4
G3VM-21UR1
-0.8
-0.4
0
0.4
1.4
IO=Continuous Load Current Ratings
IF=5mA, t<1s
1.2
1
0.8
G3VM-21UR1
0.6
0.4
0
-40
0.8
-20
0
20
40
60
80
G3VM-21UR10 : IO=100mA
G3VM-21UR1/21UR11 :
IO=100mA, t<1s
G3VM-21UR10
G3VM-21UR11
G3VM-21UR1
0.5
0
-40
-20
0
20
40
60
80
VDD=10V
RL=200Ω
Ta=25°C
tON
100
G3VM-21UR1
tON
tOFF
tOFF
G3VM-21UR10
10
1
100
10
G3VM-21UR11
G3VM-21UR1/21UR10
G3VM-21UR1
tON
G3VM-21UR10
tON
tOFF
10
-20
0
20
40
60
80
Turn ON, Turn OFF time tON, tOFF (µs)
Turn ON, Turn OFF time tON, tOFF (µs)
(Average value)
1000
-40
(Average value)
1000
tON
100
zOutput terminal capacitance
vs. Load voltage
-40
-20
3
0
G3VM-21UR10
0.8
G3VM-21UR1
0.6
0.4
20
40
60
80
100
Ambient temperature Ta (°C)
zCurrent leakage vs.
Load voltage
G3VM-21UR11
Current leakage ILEAK (pA)
Ta=25°C
(Average value)
70
Ta=25°C
60
50
G3VM-21UR11
40
30
20
G3VM-21UR10
0.2
10
0
0
5
10
15
20
Load voltage VOFF (V)
0
G3VM-21UR1
0
5
40
60
80
100
(Average value)
1000
tON
VDD=10V
RL=200Ω
Ta=25°C
100
tOFF
10
1
10
100
LED forward current IF (mA)
zCurrent leakage vs. Ambient
temperature
ILEAK-Ta
(Average value)
10000
Ta=25°C
1000
G3VM-21UR11
100
G3VM-21UR1
G3VM-21UR10
ILEAK - VOFF
(Average value)
1
20
10
10
COFF - VOFF
1.2
tOFF
VDD=10V
RL=200Ω
IF=5mA
100
Ambient temperature Ta (°C)
Output terminal capacitance COFF/COFF(0V)
G
3
V
M
I
2
1
U
R
@
0
tON, tOFF - Ta
tON, tOFF - Ta
100
-20
G3VM-21UR11
100
LED forward current IF (mA)
zTurn ON, Turn OFF time vs.
Ambient temperature
V
S
O
N
4
tON, tOFF - IF
(Average value)
1000
Ambient temperature Ta (°C)
VDD=10V
RL=200Ω
IF=5mA
6
tON, tOFF - IF
Current leakage ILEAK (pA)
1
IO=Continuous Load Current Ratings
IF=5mA, t<1s
8
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFF (µs)
1.5
RON - Ta (Average value)
0
-40
100
zTurn ON, Turn OFF time vs.
LED forward current
Turn ON, Turn OFF time tON, tOFF (µs)
Trigger LED forward current IFT (mA)
(Average value)
1.6
10
Ambient temperature Ta (°C)
G3VM-21UR1/21UR10
IFT - Ta
1.4
2
G3VM-21UR11
On-state voltage VON (V)
zTrigger LED forward current vs.
Ambient temperature
1.2
G3VM-21UR10
RON - Ta (Average value)
0.2
-1.2
-0.8
1
LED forward voltage VF (V)
On-state resistance RON (Ω)
0.4
1
zOn-state resistance vs.
Ambient temperature
On-state resistance RON (Ω)
Continuous load current IO (A)
G3VM-21UR11
Ta=25°C
IF=5mA, t<1s
0.8
10
0.1
0.8
100
G3VM-21UR1/21UR11
(Average value)
Ta=−40°C
Ta=25°C
Ta=85°C
Ambient temperature Ta (°C)
IO - VON
1.2
(Average value)
G3VM-21UR10
Ambient temperature Ta (°C)
zContinuous load current vs.
On-state voltage
IF - VF
100
200
0
-40
100
(Maximum value)
1200
zLED forward current vs.
LED forward voltage
LED forward current IF (mA)
zLED forward current vs.
Ambient temperature
10
15
20
Load voltage VOFF (V)
1
0
20
40
60
80
100
Ambient temperature Ta (°C)
G3VM-21UR@
MOS FET Relays
■Appearance / Terminal Arrangement / Internal Connections
■Appearance
■Terminal Arrangement/Internal Connections
(Top View)
VSON (Very Small Outline Non-leaded)
VSON4 pin
Model name *
* Actual model name marking for
each model
Model
Marking
2UB
1.03
G3VM-21UR10
Pin 1 mark
LOT.NO.
2UA
G3VM-21UR1
2U1
G3VM-21UR11
2UB
Note: The actual product is marked differently from the image shown here.
■Dimensions (Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad Dimensions
Weight: 0.01g
1.45±0.1
2.45±0.1
(Recommended Value, Top View)
0.75
1
1.3±0.1
0.25
0.55
0.8±0.1
0.45±0.1
Unless otherwise specified, the dimensional
tolerance is ± 0.1 mm.
0.85±0.1
0.85±0.1
Note: The actual product is marked differently from the image shown here.
■Approved Standards
Applying for UL recognition
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
V
S
O
N
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K267-E1-03
0215(0814)(O)
4
G
3
V
M
I
2
1
U
R
@