G3VM-61UR@/81UR@/101UR MOS FET Relays VSON package with High Load voltage World's smallest New VSON Package with High Load voltage • Load voltage 60V/80V/100V RoHS Compliant Refer to "Common Precautions". Note: The actual product is marked differently from the image shown here. ■Application Examples • Semiconductor test equipment • Communication equipment • Test & measurement equipment • Data loggers ■Package (Unit : mm, Average) ■Model Number Legend G 3 V M -@ @ @ @ @ 2 U 4 B 3 2 1 2 3 4 5 1. Load Voltage 6: 60V 8: 80V 10: 100V 1.3 2.45 1.45 Note: The actual product is marked differently from the image shown here. 3. Package type U: VSON 4 pin 4. Additional functions R: Low On-resistance 5. Other informations When specifications overlap, serial code is added in the recorded order. 2. Contact form 1: 1a (SPST-NO) ■Ordering Information Package type Contact form Terminals Load voltage (peak value) * 60V VSON4 1a (SPST-NO) Surface-mounting Terminals 80V 100V Packing/Tape cut Packing/Tape & reel Continuous load current (peak value) * Model 120mA G3VM-61UR1 G3VM-61UR1(TR05) 400mA G3VM-61UR G3VM-61UR(TR05) Minimum package quantity Model 120mA G3VM-81UR 200mA G3VM-81UR1 G3VM-81UR1(TR05) 100mA G3VM-101UR G3VM-101UR(TR05) 1 pc. G3VM-81UR(TR05) Minimum package quantity 500 pcs. Note: When ordering tape packing, add "(TR05)" (500pcs/reel) to the model number. Ask your OMRON representative for orders under 500 pcs. We can supply products with the tape already cut. Tape-cut VSONs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. * The AC peak and DC value are given for the load voltage and continuous load current. V S O N ■Absolute Maximum Ratings (Ta = 25°C) Item Symbol G3VM-61UR1 G3VM-61UR G3VM-81UR G3VM-81UR1G3VM-101UR IF 30 Unit ΔIF/°C −0.3 VR 5 V Connection temperature TJ 125 °C Continuous load current (AC peak/DC) VOFF 60 IO 120 mA/°C Ta≥25°C 80 400 120 200 100 V 100 mA ΔIO/°C −1.2 −4.0 −1.2 −2 −1 Pulse ON current lop 360 1200 360 600 300 Connection temperature TJ 125 °C Dielectric strength between I/O (See note 1.) VI-O 300 Vrms ON current reduction rate Ambient operating temperature Ambient storage temperature Soldering temperature Measurement conditions mA LED reverse voltage LED forward current reduction rate Load voltage (AC peak/DC) Output G 3 V M I 6 1 U R @ / 8 1 U R @ / 1 0 1 U R Input LED forward current mA/°C Ta≥25°C mA Ta −40~+85 °C Tstg −40~+125 °C − 260 °C t=100ms, Duty=1/10 AC for 1 min With no icing or condensation 10s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. 1 G3VM-61UR@/81UR@/101UR MOS FET Relays ■Electrical Characteristics (Ta = 25°C) Item Symbol Output Input LED forward voltage VF G3VM-61UR1 G3VM-61UR G3VM-81UR G3VM-81UR1 G3VM-101UR Unit Minimum 1.1 Typical 1.27 Maximum 1.4 V Measurement conditions IF=10mA Reverse current IR Maximum 10 μA VR=5V Capacity between terminals CT Typical 30 pF V=0, f=1MHz Trigger LED forward current IFT mA IO=100mA Release LED forward current IFC Maximum resistance with output ON RON Current leakage when the relay is open ILEAK Capacity between terminals COFF Capacity between I/O terminals CI-O Insulation resistance between I/O terminals RI-O Turn-ON time tON Turn-OFF time tOFF Typical − 1 Maximum 1 − 3 Minimum 0.1 mA Typical 10 1.0 7 6 8 Maximum 15 1.5 12 8 14 0.02 1 0.2 Maximum 1 Typical 0.7 20 5 6.5 6 Maximum 1.3 − 7 11 8 IOFF=10μA Ω IF=5mA, t<1s, IO=Continuous load current ratings nA VOFF=Load voltage ratings pF V=0, f=100MHz, t<1s Typical 1 pF f=1MHz, VS=0V Typical 108 MΩ VI-O=500VDC, ROH≤60% ms IF=5mA, RL=200Ω, VDD=20V (See note 2.) Typical 0.05 Maximum 0.2 Typical 0.015 Maximum 0.2 − 0.5 0.5 0.4 0.3 0.4 0.3 − 0.5 0.2 Note: 2. Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% 90% t ON t OFF ■Recommended Operating Conditions For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature Symbol VDD IF IO Ta G3VM-61UR1 Maximum G3VM-61UR G3VM-81UR 48 Minimum 5 Typical 7.5 Maximum 20 Maximum 120 G3VM-81UR1 64 400 120 Minimum −20 Maximum 65 G3VM-101UR Unit 80 V mA 200 100 °C V S O N 2 G 3 V M I 6 1 U R @ / 8 1 U R @ / 1 0 1 U R G3VM-61UR@/81UR@/101UR MOS FET Relays ■Engineering Data zLED forward current vs. Ambient temperature zContinuous load current vs. Ambient temperature IO - Ta 30 25 20 15 10 G3VM-61UR 400 300 G3VM-81UR1 200 G3VM-61UR1 G3VM-81UR 0 20 40 60 80 -20 0 Continuous load current IO (mA) IO - VON (Average value) 500 G3VM-61UR Ta=25°C IF=5mA, t<1s 300 40 60 80 100 G3VM-81UR/81UR1/101UR G3VM-61UR/61UR1 400 20 Ambient temperature Ta (°C) zContinuous load current vs. On-state voltage 200 100 G3VM-61UR1 0 -100 -200 -300 -1.5 IO - VON (Average value) 300 Ta=25°C IF=5mA, t<1s 200 G3VM-81UR1 G3VM-81UR 100 G3VM-101UR 0 -100 -1 -0.5 0 0.5 1 1.2 1.4 1.6 LED forward voltage VF (V) zOn-state resistance vs. Ambient temperature RON - Ta (Average value) 20 IO=Continuous Load Current Ratings IF=5mA, t<1s 15 G3VM-61UR1 G3VM-101UR 10 G3VM-81UR G3VM-81UR1 5 0 -1.5 1.5 -1 -0.5 0 0.5 1 1.5 -40 On-state voltage VON (V) zTrigger LED forward current vs. Ambient temperature G3VM-81UR1 G3VM-61UR G3VM-61UR1 1 G3VM-101UR G3VM-81UR 0 -40 -20 0 20 40 60 80 100 VDD=20V RL=200Ω Ta=25°C tON G3VM-61UR 100 tON tOFF tOFF 10 G3VM-61UR1 1 10 100 G3VM-61UR1 tON G3VM-61UR G3VM-61UR1 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) zCurrent leakage vs. Ambient temperature (Average value) VOFF=Load Voltage Ratings G3VM-101UR 10000 G3VM-81UR 1000 G3VM-61UR 100 G3VM-61UR1 G3VM-81UR1 10 0 20 40 G3VM-81UR G3VM-81UR1 G3VM-101UR 100 G3VM-81UR G3VM-101UR tON tOFF tOFF 60 tON 80 100 Ambient temperature Ta (°C) G3VM-81UR1 G3VM-101UR 100 G3VM-81UR G3VM-101UR tOFF tOFF tOFF G3VM-81UR1 10 1 10 100 LED forward current IF (mA) ILEAK - VOFF (Average value) 50 Ta=25°C G3VM-101UR 40 30 G3VM-61UR 20 G3VM-61UR1 10 G3VM-81UR1 G3VM-81UR1 10 -40 -20 0 20 40 60 80 G3VM-81UR 100 zOutput terminal capacitance vs. Load voltage COFF - VOFF ILEAK - Ta 100000 1 VDD=20V RL=200Ω IF=5mA Ambient temperature Ta (°C) Output terminal capacitance COFF/COFF(0V) 10 -40 tOFF tOFF Turn ON, Turn OFF time tON, tOFF (µs) tON (Average value) 1000 VDD=20V RL=200Ω Ta=25°C G3VM-81UR tON, tOFF - Ta tON, tOFF - Ta G3VM-61UR 100 zCurrent leakage vs. Load voltage G3VM-81UR/81UR1/101UR G3VM-61UR/61UR1 VDD=20V RL=200Ω IF=5mA 80 (Average value) 100 zTurn ON, Turn OFF time vs. Ambient temperature (Average value) 60 1000 LED forward current IF (mA) Ambient temperature Ta (°C) 1000 40 tON, tOFF - IF (Average value) 1000 Current leakage ILEAK (pA) IO=100mA t<1s 20 G3VM-81UR/81UR1/101UR Turn ON, Turn OFF time tON, tOFF (µs) Turn ON, Turn OFF time tON, tOFF (µs) (Average value) 0 zTurn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 2 -20 Ambient temperature Ta (°C) G3VM-61UR/61UR1 IFT - Ta Trigger LED forward current IFT (mA) 1 -200 On-state voltage VON (V) Turn ON, Turn OFF time tON, tOFF (µs) 1 0.8 -300 -500 Current leakage ILEAK (pA) 10 G3VM-61UR -400 3 Ta=85°C 0.1 -40 100 On-state resistance RON (Ω) -20 Ambient temperature Ta (°C) G 3 V M I 6 1 U R @ / 8 1 U R @ / 1 0 1 U R Ta=−40°C Ta=25°C G3VM-101UR 0 0 -40 V S O N (Average value) 100 100 5 Continuous load current IO (mA) IF - VF (Maximum value) 500 LED forward current IF (mA) (Maximum value) 35 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta zLED forward current vs. LED forward voltage (Average value) 1.2 Ta=25°C 1 0.8 G3VM-61UR1 0.6 G3VM-101UR 0.4 G3VM-81UR1 0.2 G3VM-61UR G3VM-81UR 0 0 10 20 30 40 Load voltage VOFF (V) 0 0 20 40 60 80 100 Load voltage VOFF (V) G3VM-61UR@/81UR@/101UR MOS FET Relays ■Appearance / Terminal Arrangement / Internal Connections ■Appearance VSON (Very Small Outline Non-leaded) VSON4 pin Model name * ■Terminal Arrangement/Internal Connections (Top View) * Actual model name marking for each model Model 2UB 1.03 Pin 1 mark LOT.NO. Marking G3VM-61UR1 6U1 G3VM-61UR 6U0 G3VM-81UR 8U0 G3VM-81UR1 8U1 G3VM-101UR AU0 Note: The actual product is marked differently from the image shown here. ■Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.01g 1.45±0.1 2.45±0.1 (Recommended Value, Top View) 0.75 2 U 4 B 3 2 1.3±0.1 1 0.25 0.55 0.8±0.1 0.45±0.1 Unless otherwise specified, the dimensional tolerance is ±0.1 mm. 0.85±0.1 0.85±0.1 Note: The actual product is marked differently from the image shown here. ■Approved Standards Applying for UL recognition ■Safety Precautions • Refer to "Common Precautions" for all G3VM models. V S O N G 3 V M I 6 1 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. U • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious R influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or @ equipment, and be sure to provide the system or equipment with double safety mechanisms. / 8 1 Note: Do not use this document to operate the Unit. U R @ OMRON Corporation / Cat. No. K269-E1-03 1 Contact: www.omron.com/ecb Electronic and Mechanical Components Company 0215(0814)(O) 0 1 U R 4