Datasheet

For more information, please visit the product page.
date
07/11/2013
page
1 of 5
SERIES: VIAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
•
isolated 1 W output
regulated
dual voltage output
small footprint
industry standard 10 pin DIP package
UL94-V0 package
no heatsink required
1,000 Vdc isolation
temperature range: -40°C~+85°C
no external component required
efficiency up to 66%
RoHS
input
voltage
MODEL
output
voltage
output
current
output
power
ripple1
noise1
efficiency
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
VIAS1-S5-D5-SIP
5
4.75 ~ 5.25
±5
±10
±100
1
20
100
54
VIAS1-S5-D9-SIP
5
4.75 ~ 5.25
±9
±6
±56
1
20
100
64
VIAS1-S5-D12-SIP
5
4.75 ~ 5.25
±12
±5
±42
1
20
100
64
VIAS1-S5-D15-SIP
5
4.75 ~ 5.25
±15
±4
±33
1
20
100
64
VIAS1-S12-D5-SIP
12
11.4 ~ 12.6
±5
±10
±100
1
20
100
55
VIAS1-S12-D9-SIP
12
11.4 ~ 12.6
±9
±6
±56
1
20
100
60
VIAS1-S12-D12-SIP
12
11.4 ~ 12.6
±12
±5
±42
1
20
100
66
VIAS1-S12-D15-SIP
12
11.4 ~ 12.6
±15
±4
±33
1
20
100
64
VIAS1-S24-D5-SIP
24
22.8 ~ 25.2
±5
±10
±100
1
20
100
54
VIAS1-S24-D9-SIP
24
22.8 ~ 25.2
±9
±6
±56
1
20
100
64
VIAS1-S24-D12-SIP
24
22.8 ~ 25.2
±12
±5
±42
1
20
100
64
VIAS1-S24-D15-SIP
24
22.8 ~ 25.2
±15
±4
±33
1
20
100
64
Notes:
1. ripple and noise are measured at 20 MHz BW
PART NUMBER KEY
VIAS1 -SXX -DXX -SIP
Base Number
Input Voltage
cui.com
Output Voltage
For more information, please visit the product page.
CUI Inc │ SERIES: VIAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/11/2013 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
24 V model
4.75
11.4
22.8
5
12
24
5.75
12.6
25.2
Vdc
Vdc
Vdc
no load power consumption
10% nominal power (typical)
min
typ
max
units
0.25
%
OUTPUT
parameter
conditions/description
line regulation
For Vin change of 1%, full load
load regulation
10% to 100% full load
±1
%
voltage accuracy
100% full load
±3
%
switching frequency
100% load, nominal input
100
temperature coefficient
kHz
0.03
%/°C
max
units
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
typ
1
s
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
tested for 1 minute
1,000
min
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
RoHS compliant
yes
3,500,000
hrs
MTBF
typ
max
units
ENVIRONMENTAL
parameter
conditions/description
min
case operating temperature
storage temperature
storage humidity
non-condensing
temperature rise
100% load
lead temperature
1.5 mm from the case for 10 seconds
typ
max
units
-40
85
°C
-55
125
°C
95
%
25
°C
300
°C
15
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/11/2013 │ page 3 of 5
DERATING CURVES
Load (%)
100
80
60
40
20
-40
-20
0
20
40
60 71 80
100
120
Ambient Temperature (°C)
MECHANICAL
parameter
conditions/description
min
dimensions
27.5 x 9.50 x 12.0 (1.08 x 0.37 x 0.47 inch)
case material
Plastic (UL94-V0)
typ
max
units
mm
weight
5.2
g
MECHANICAL DRAWING
units: mm (inches)
tolerance: ±0.25 (±0.010)
pin section tolerance: ±0.10 mm (±0.004)
27.5 0 (1.083)
R ECOMMENDED FO OTPRINT
+0.020
(0.1 6 0 0
4.10 0
12.00
( 0. 472)
+0.50
)
B ottom v iew,grid:2.54mm( 0.1inc h),
diameter:1:00mm(0.039i nch)
1
2
7
PIN CONNECTIONS
2.32
(0.091)
1 2
7
9 10
9.50
( 0.374 )
1.25
(0.049)
PIN
2.54 (0.10 0)
cui.com
FUNCTION
1
Vin
2
GND
7
+Vo
9
-Vo
10
0V
9 10
For more information, please visit the product page.
CUI Inc │ SERIES: VIAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/11/2013 │ page 4 of 5
APPLICATION NOTES
1.
Requirement on output load
To ensure this module can operate efficiently and reliably, a minimum load is specified for this kind of DC/DC converter in addition to
a maximum load (namely full load). During operation, make sure the specified range of input voltage is not exceeded, the minimum
output load is not less than 10% of the full load, that this product should never be operated under no load! If the actual output power
is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load, or use our company’s
products with a lower rated output power (VIAS1-SIP series).
2.
Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end
to reduce the noise and ripple. However, the capacitance of the output filter capacitor must proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, providing the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor refer to the EXTERNAL CAPACITOR TABLE. To get an extreme low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (see figure 1).
3.
Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
External Capacitor Table
Note:
Vin
External capacitor
Vout
External capacitor
5 Vdc
4.7 uF
5 Vdc
4.7 μF
12 Vdc
2 .2uF
9 Vdc
2.2 μF
24 Vdc
1 uF
12 Vdc
1.0 μF
--
--
15 Vdc
0.47 μF
All specifications measured at 25°C, humidity <75%, nominal input voltage, and full load unless otherwise noted.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIAS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/11/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
06/19/2006
1.01
new template applied
01/11/2008
1.02
new template applied, V-Infinity branding removed
09/07/2012
updated spec
07/11/2013
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.