データシート

For more information, please visit the product page.
date
09/11/2012
page
1 of 5
SERIES: VWRAS3 │ DESCRIPTION: DC-DC CONVERTER
3 W isolated output
wide input (2:1)
industry standard 8 pin SIP package
dual unregulated outputs
1,500 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 83%
U
•
•
•
•
•
•
•
•
ED
FEATURES
input
voltage
MODEL
output
voltage
output
current
output
power
ripple1
noise1
efficiency
max
(mA)
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
±300
3
100
150
80
typ
(Vdc)
range
(Vdc)
(Vdc)
12
9.0~18.0
±5
TI
VWRAS3-D12-D5-SIP
N
RoHS
VWRAS3-D12-D9-SIP
12
9.0~18.0
±9
±167
3
100
150
81
VWRAS3-D12-D12-SIP
12
9.0~18.0
±12
±125
3
100
150
82
12
9.0~18.0
±15
±100
3
100
150
83
24
18.0~36.0
±5
±300
3
100
150
80
N
VWRAS3-D12-D15-SIP
VWRAS3-D24-D5-SIP
VWRAS3-D24-D9-SIP
VWRAS3-D24-D12-SIP
VWRAS3-D24-D15-SIP
18.0~36.0
±9
±167
3
100
150
81
18.0~36.0
±12
±125
3
100
150
82
24
18.0~36.0
±15
±100
3
100
150
83
O
1. ripple and noise are measured at 20 MHz BW
IS
C
Notes:
24
24
D
PART NUMBER KEY
Base Number
VWRAS3 - DXX - DXX -SIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS3 │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
12 V model
24 V model
9.0
18.0
12
24
18.0
36.0
Vdc
Vdc
parameter
conditions/description
min
line regulation
input voltage from low to high
load regulation
measured from 10% load to full load
OUTPUT
voltage accuracy
input voltage range refer to output load
switching frequency
100% load, input voltage range
typ
max
units
±0.2
±0.5
%
±0.5
±1.0
%
±1
200
±3
%
400
kHz
±0.03
U
temperature coefficient
ED
parameter
PROTECTIONS
conditions/description
short circuit protection
continuous
min
N
parameter
SAFETY AND COMPLIANCE
typ
max
units
typ
max
units
conditions/description
isolation voltage
for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
1,000,000
hours
yes
ENVIRONMENTAL
operating temperature
storage temperature
storage humidity
temperature rise
min
max
units
-40
typ
85
°C
-50
125
°C
95
%
35
°C
300
°C
non-condensing
at full load
15
1.5 mm from case for 10 seconds
D
IS
C
lead temperature
conditions/description
O
parameter
N
RoHS compliant
TI
parameter
MTBF
min
%/°C
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS3 │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 3 of 5
DERATING CURVES
100
60
40
20
-20
0
20
40
60 71
85
Ambient Temperature (°C)
parameter
conditions/description
dimensions
0.866 x 0.374 x 0.472 (22.00 x 9.50 x 12.00 mm)
case material
plastic (UL94-V0)
O
(Bott om View)
1
2
2.50
[ 0.098]
5
3
6
typ
(S ide View)
7 8
max
6
g
4. 10 [ 0.161]
IS
C
2.54[0.100]
17.78[0. 700]
PIN CONNECTIONS
1
2
3
5
2.54[ 0.100]
6
7 8
2.5 0[0.098]
ø1.00 [0.039]
2.10 [0.083]
cui.com
PIN
FUNCTION
1
GND
2
Vin
3
CTRL
5
NC
6
+Vo
7
0V
8
-Vo
units
inch
0.50[ 0.020]
2. 54[0 .100]
9.50
[0.374]
22.00 [0.866]
0 .30[ 0.01 2]
N
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
1 2.00
[0 .472 ]
MECHANICAL DRAWING
D
min
TI
weight
120
N
MECHANICAL
100
U
-40
0. 50[0 .020]
Load (%)
80
ED
1. output power vs. ambient temperature
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS3 │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 4 of 5
APPLICATION NOTES
Vout
±5 V
±680
±9 V
±330
±12 V
±220
±15 V
±150
U
Table 1
Cout/μF (max)
ED
-All of the VWRAS3 Series have been tested according to the following recommended testing circuit before leaving the factory.
This series should be tested under load (Figure 1). If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high (Table 1).
NCs Terminals
Unless otherwise specified, NC terminals of all series are used for converter's interior circuit connection, and are not allowed connection of any external circuit
2.
CTRL Terminal
When open or high impedance, the converter will work well; When this pin is ‘high’; the converter will shutdown; It should be noted
that the input current should remain between 5-10mA,exceeding the maximum 20mA will cause permanent damage to the converter.
3.
Input current
Nominal input voltage range. The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC module (Figure 2)
TI
Ip
N
Figure 1
Input Current(A)
N
1.
Input Voltage
Range
Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded.
IS
C
4.
O
Input Voltage (V)
D
No parallel connection or plug and play.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VWRAS3 │ DESCRIPTION: DC-DC CONVERTER
date 09/11/2012 │ page 5 of 5
REVISION HISTORY
description
date
07/25/2007
1.0
initial release
1.01
new template applied
1.02
new template applied, V-Infinity branding removed
ED
rev.
07/23/2010
09/11/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.