Datasheet

For more information, please visit the product page.
date
02/18/2015
page
1 of 5
SERIES: VIESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
isolated 1 W output
regulated
high efficiency to 73%
dual voltage output
small footprint
SIP package style
industry standard pinout
UL94-V0 package
no heatsink required
3,000 Vdc isolation
temperature range: -40°C~+85°C
no external component required
low cost
RoHS
MODEL
input
voltage
typ
(Vdc)
output
voltage
output
current
output
power
ripple
noise
efficiency
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
VIESD1-S5-D5-SIP
5
4.75 ~ 5.25
5
±10
±100
1
15
15
69
VIESD1-S5-D9-SIP
5
4.75 ~ 5.25
9
±6
±56
1
15
15
70
VIESD1-S5-D12-SIP
5
4.75 ~ 5.25
12
±5
±42
1
15
15
72
VIESD1-S5-D15-SIP
5
4.75 ~ 5.25
15
±4
±33
1
15
15
72
VIESD1-S12-D5-SIP
12
11.4 ~ 12.6
5
±10
±100
1
15
15
70
VIESD1-S12-D9-SIP
12
11.4 ~ 12.6
9
±6
±56
1
15
15
72
VIESD1-S12-D12-SIP
12
11.4 ~ 12.6
12
±5
±42
1
15
15
73
VIESD1-S12-D15-SIP
12
11.4 ~ 12.6
15
±4
±33
1
15
15
73
VIESD1-S24-D5-SIP
24
22.8 ~ 25.2
5
±10
±100
1
15
15
72
VIESD1-S24-D9-SIP
24
22.8 ~ 25.2
9
±6
±56
1
15
15
72
VIESD1-S24-D12-SIP
24
22.8 ~ 25.2
12
±5
±42
1
15
15
73
VIESD1-S24-D15-SIP
24
22.8 ~ 25.2
15
±4
±33
1
15
15
73
PART NUMBER KEY
VIESD1 -SXX -DXX -SIP
Base Number
Input Voltage
cui.com
Output Voltage
For more information, please visit the product page.
CUI Inc │ SERIES: VIESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/18/2015 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
24 V model
4.75
11.4
22.8
5
12
24
5.75
12.6
25.2
Vdc
Vdc
Vdc
parameter
conditions/description
min
typ
max
units
line regulation
For Vin change of 1%, full load
0.25
%
load regulation
10% to 100% full load
1
%
voltage accuracy
100% full load
switching frequency
100% load, nominal input
OUTPUT
±3
100
temperature coefficient
%
kHz
0.03
%/°C
max
units
PROTECTIONS
parameter
conditions/description
min
short circuit protection
continuous, automatic recovery
typ
<1
s
SAFETY AND COMPLIANCE
parameter
conditions/description
min
isolation voltage
tested for 1 minute
3,000
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
RoHS compliant
yes
3,500,000
hrs
MTBF
typ
max
units
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
case operating temperature
-40
85
°C
storage temperature
-55
125
°C
storage humidity
non-condensing
temperature rise
100% load
lead temperature
1.5 mm from the case for 10 seconds
15
cui.com
<95
%
25
°C
300
°C
For more information, please visit the product page.
CUI Inc │ SERIES: VIESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/18/2015 │ page 3 of 5
DERATING CURVES
Temperature Derating Graph
Operating Temp.( C )
MECHANICAL
parameter
conditions/description
min
dimensions
27.5 x 9.5 x 12.0 (1.08 x 0.37 x 0.47 inch)
case material
Plastic (UL94-V0)
typ
max
mm
weight
5.2
g
MECHANICAL DRAWING
PIN CONNECTIONS
Function
1
Vin
2
GND
7
+Vo
9
-Vo
10
0V
0.50[0.020]
0.50[0.020]
(Front View)
4.10 [0 .161 ]
1 2.00
[0 .4 72 ]
units: mm [inches]
tolerance: ±0.25mm [±0.010]
pin section tolerance: ±0.10mm [±0.004]
Pin
1.00[0.039]
9.50
[0.3 74]
27.50[1.083]
0.90 [0.035]
17.78 [0.700]
22.86[0.900]
Note grid 2.54 x 2.54mm
(Bottom View)
cui.com
units
For more information, please visit the product page.
CUI Inc │ SERIES: VIESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/18/2015 │ page 4 of 5
APPLICATION NOTES
1. Filtering
To get an extreme low ripple, an “LC” fi ltering network may be connected to the input and output ends of the DC/DC converter, which
may produce a more signifi cant fi ltering effect. It should also be noted that the inductance and the frequency of the “LC” filtering
network should be staggered with the DC/DC frequency to avoid mutual interference see (see Figure 1).
Figure 1
Vin
GND
L
L
C
DC DC
C
L
C
+Vo
0V
-Vo
In some circuits which are sensitive to noise and ripple, a fi ltering capacitor may be added to the DC/DC output end and input end
to reduce the noise and ripple. However, the capacitance of the output fi lter capacitor must proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, providing the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor refer to the external capacitor table (see Tables 1 and 2).
Table 1
Input Voltage
(Vdc)
External Input Capacitance
(µF)
5V
4.7
12 V
2.2
24 V
1.0
Table 2
Vout
(Vdc)
External Output
Capacitance
(µF)
±5 V
4.7
±9 V
2.2
±12 V
1.0
±15 V
0.47
2. Overload protection
Under normal operating conditions, the output circuit of these products has no protection against over-current. The simplest method
is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. When the environment temperature
is higher than 71°C, the product output power should be less then 60% of the rated power.
3. No parallel connection or plug and play
Use dual output simultaneously, forbid opening output pin(0V) to use as single output.
Note:
All specifications measured at 25°C, humidity <75%, nominal input voltage, and full load unless otherwise noted.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/18/2015 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
06/27/2007
1.01
new template applied, V-Infinity branding removed
09/10/2012
1.02
updated spec
07/11/2013
updated drawing images
02/18/2015
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.