HCTF CP Series Datasheet

HCTF CP Series
www.vishay.com
Vishay Beyschlag
High Current Thermal Fuse
FEATURES
• Functioning temperature: F = (235 ± 15) °C
• Holding temperature: H = 160 °C
• Current:  50 A
• Suitable for insert assembly systems
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
APPLICATIONS
• Automotive
- Fan control units
The HCTF CP series is especially designed for high current
applications with an operating temperature up to 160 °C. In
case of excess heat in the range of the functioning
temperature of (235 ± 15) °C the thermo fuse opens
automatically and disconnects the circuit. Typical
applications are automotive power electronics that are
connected to steady battery power (B+ or terminal
number 30).
- ABS
- Diesel glow plug relays
- Diesel pre-heaters
- Electric coolant pumps
TECHNICAL SPECIFICATIONS
DESCRIPTION
HCTF 235 CP
Functioning temperature F
(235 ± 15) °C
Holding temperature H (1000 h)
160 °C
24 V
Voltage UDC
Current IDC
 50 A
(1)
 0.1 m
Cold resistance Rcold
> 1 M
Residual resistance Rs
Note
(1) Current rating depends on external thermal management.
DIMENSIONS
W1
W2
D1
D2
DIMENSIONS - Mass and relevant physical dimensions
TYPE
HCTF CP
W1
(mm)
W2
(mm)
D1 (2)
(mm)
D2
(mm)
MASS
(g)
26 ± 0.5
6.5 ± 0.5
7.7 ± 0.3
1.8 ± 0.2
1.45 ± 0.3
Note
(2) Between sleek surfaces
Revision: 10-Apr-13
Document Number: 28850
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
HCTF CP Series
www.vishay.com
Vishay Beyschlag
PART NUMBER AND PRODUCT DESCRIPTION
(1)
PART NUMBER: HCTF235L150000BR00
H
C
T
F
2
3
5
L
1
5
0
0
0
0
B
R
0
0
TYPE/
FUNCTIONING
TEMPERATURE
TOLERANCE
SPECIAL
CURRENT
PACKAGING
SPECIAL
HCTF235
L = ± 15 °C
1 digit
1 = Clamp
Current in mA.
50000 = 50 A
BR
Up to 2 digits
00 = Standard
PRODUCT DESCRIPTION: HCTF 235 15 °C CP BR 50A0
HCTF
235
15 °C
CP
BR
50A0
TYPE
FUNCTIONING
TEMPERATURE
TOLERANCE
SPECIAL
PACKAGING
RATED CURRENT VALUE
HCTF
235
± 15 °C
CP = Clamp
BR
50A0 = 50 A
Note
(1) Products can be ordered using either the PART NUMBER or the PRODUCT DESCRIPTION
PACKAGING
TYPE
HCTF CP
CODE
QUANTITY
CARRIER TAPE
WIDTH
PITCH
REEL
DIAMETER
BR
750
Blister tape
acc. IEC 60286-3
Type III
44 mm
12 mm
360 mm/14.2"
ASSEMBLY
The high current thermal fuse HCTF 235 CP is suitable for processing on automatic insert assembly systems e.g. into clamp or
crimp terminations. Any deformation and overheating of the component body to levels above the holding temperature has to
be avoided during the assembly.
The HCTF 235 CP complies with the JIG 101 list of legal restrictions on hazardous substances.
This includes full compliance with the following directives:
• 2000/53/EC End of Life Vehicle Directive (ELV) and Annex II (ELV II)
• 2011/65/EU Restriction of the use of Hazardous Substances Directive (RoHS)
• 2002/96/EC Waste Electrical and Electronic Equipment Directive (WEEE)
RELATED PRODUCTS
A version for automatic electric resistance welding assembly systems is available, too. See the datasheet:
• HCTF 235 Series: www.vishay.com/doc?28798
Revision: 10-Apr-13
Document Number: 28850
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
HCTF CP Series
www.vishay.com
Vishay Beyschlag
FUNCTIONAL PERFORMANCE
120
Current Rating Factor (%)
110
100
90
80
70
60
50
40
30
20
10
0
- 60 - 40 - 20
0
20
40
60
80
100 120 140 160 180
Ambient Temperature ϑamb (°C)
Current Rating Factor vs. Ambient Temperature amb
Note
• The current rating factor depends on the mounting and environmental conditions. The power dissipation on the thermal fuse generates a
temperature rise against the local ambient, depending on the heat flow supported by additional conductive materials as electrical wires, lead
frames or other electrical connections (thermal resistance). Please contact the factory (please refer to e-mail contact below) for support and
further technical details.
TESTS AND REQUIREMENTS
All tests are carried out in accordance with the following test
procedures and specifications:
Unless otherwise specified the following values apply:
IEC 60115-1
Relative humidity: 25 % to 75 %
IEC 60068-1
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
Temperature: 15 °C to 35 °C
IEC 61340-3-1
MIL-STD-202
The tests are carried out under standard atmospheric
conditions in accordance with IEC 60068-1, 5.3.
TEST PROCEDURES AND REQUIREMENTS
IEC 60068-2
TEST
METHOD
TEST
PROCEDURE
REQUIREMENTS
4.25.3
-
Endurance
Unpowered;
160 °C; 500 h
R  0.2 m
-
-
Operational life acc. to
MIL-STD-202
METHOD 108A
50 A;
1000 h;
case temperature max. 160 °C
R  0.2 m
4.19
14 (Na)
Rapid change of
temperature
10 min at - 55 °C and
10 min at 155 °C;
transition time < 10 s;
1000 cycles
R  0.2 m
4.23.6
30 (Db)
Damp heat, cyclic
55 °C; 5 days > 90 % RH;
5 cycles
R  0.2 m
Mechanical shock
Half sine pulse shape;
6 ms;
peak acceleration 100 g;
3 shocks in both directions
of each axis
R  0.2 m
EN 60115-1
CLAUSE
-
27 (Ea)
Revision: 10-Apr-13
Document Number: 28850
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
HCTF CP Series
www.vishay.com
Vishay Beyschlag
TEST PROCEDURES AND REQUIREMENTS
EN 60115-1
CLAUSE
IEC 60068-2
TEST
METHOD
TEST
PROCEDURE
REQUIREMENTS
R  0.2 m
4.22
6 (Fc)
Vibration
f1: 10 Hz; f2: 2000 Hz
amplitude ± 1.5 mm or
acceleration 50 m/s2 (5 g),
whatever is less severe
20 min/cycle (f1 - f2 - f1);
10 cycles each for 3 axes
4.40
-
ESD;
Human body model
acc. to IEC 61340-3-1
U = 4 kV; C = 100 pF; R = 1.5 k;
3 pos. + 3 neg.
R  0.2 m
-
-
Time until opening
Unpowered;
pre-heated at 200 °C
oil bath at 275 °C ± 5 K
 2.0 min
4.16
21 (Ua1)
Robustness of
terminations
Tensile force
(40 ±4) N;
10 s
R  0.2 m
4.35
-
Flammability
Needle flame test; 10 s
No burning after 30 s
Revision: 10-Apr-13
Document Number: 28850
4
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000