VACR www.vishay.com Vishay Draloric Aluminum Housed Compact Wirewound Resistor FEATURES • Power rating up to 500 W • High overload capacity • Protection IP20 or IP65 • Enhanced humidity protection • Complete housed construction • Multiple construction for higher power rating • Heatsink mounting • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 APPLICATIONS • Drive controllers • Railway • Frequency inverter • Renewable energy STANDARD ELECTRICAL SPECIFICATIONS MODEL VACR0500 POWER RATING W P40 °C 50 RESISTANCE RANGE (1) TEMPERATURE COEFFICIENT ppm/K TOLERANCE ±% PROTECTION MAX. PERMISSIBLE OPERATING VOLTAGE UL 600 V/UL 1000 V 3.0 to 560 50 to 150 10 IP65 3.0 to 560 50 to 150 10 IP65 EN 1000 V DC 100 2.7 to 910 50 to 150 10 IP65 UL 600 V/UL 1000 V 6.2 to 1.2K 50 to 150 10 IP65 UL 600 V/UL 1000 V VACR1202 120 4.7 to 1.0K 50 to 150 10 IP65 UL 600 V/UL 1000 V VACR1301 130 2.7 to 910 50 to 150 10 IP65 EN 1000 V DC 2.7 to 910 50 to 150 10 IP20 UL 600 V/UL 1000 V 4.7 to 1.0K 50 to 150 10 IP65 EN 1000 V DC 6.2 to 1.2K 50 to 150 10 IP65 EN 1000 V DC VACR1504 6.2 to 1.2K 50 to 150 10 IP65 UL 600 V/UL 1000 V VACR1505 9.1 to 1.5K 50 to 150 10 IP65 UL 600 V/UL 1000 V 6.2 to 1.2K 50 to 150 10 IP65 EN 1000 V DC 8.2 to 1.8K 50 to 150 10 IP65 UL 600 V/UL 1000 V VACR1000 VACR1001 VACR1003 VACR1501 VACR1502 VACR1503 VACR1804 VACR1806 VACR2001 VACR2005 VACR2502 VACR2506 VACR3002 VACR3004 VACR4004 VACR4006 VACR5006 150 180 200 250 300 400 500 3.3 to 910 50 to 150 10 IP20 EN 1000 V DC 9.1 to 1.5K 50 to 150 10 IP65 EN 1000 V DC 4.7 to 1.0K 50 to 150 10 IP20 UL 600 V/UL 1000 V 8.2 to 1.8K 50 to 150 10 IP65 EN 1000 V DC 4.7 to 1.0K 50 to 150 10 IP20 EN 1000 V DC 6.2 to 1.2K 50 to 150 10 IP20 UL 600 V/UL 1000 V 6.2 to 1.2K 50 to 150 10 IP20 EN 1000 V DC 8.2 to 1.8K 50 to 150 10 IP20 UL 600 V/UL 1000 V 8.2 to 1.8K 50 to 150 10 IP20 EN 1000 V DC Notes • VACR100 and VACR200 as special flat version on request. (1) Resistance value to be selected from E24 series, other values on request. Revision: 08-May-14 Document Number: 21035 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VACR www.vishay.com PULSE POWER in W at Ta = 40 °C MAX. PERMISSIBLE OPERATING VOLTAGE UL 600 V/UL 1000 V UL 600 V/UL 1000 V EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC UL 600 V/UL 1000 V EN 1000 V DC EN 1000 V DC MODEL VACR050 VACR100 (1) Vishay Draloric (3) VACR120 VACR130 VACR150 VACR180 VACR200 (3) VACR250 VACR300 VACR400 SIZE: 40 mm x 20 mm SIZE: 60 mm x 30 mm PULSE TIME (2) 6% 15 % 25 % 40 % 6% 15 % 25 % 40 % 550 950 1600 1600 2200 3200 - 200 400 650 650 900 1300 - 150 250 400 400 550 750 - 100 150 250 250 350 500 - 900 1080 1170 1350 1350 1620 1620 1800 2250 2250 2700 2700 3600 3600 4500 500 600 650 750 750 900 900 1000 1250 1250 1500 1500 2000 2000 2500 300 360 390 450 450 540 540 600 750 750 900 900 1200 1200 1500 200 240 260 300 300 360 360 400 500 500 600 600 800 800 1000 VACR500 Notes (1) Approximate value (depending on resistance) (2) Cycle duration of 120 s PART NUMBER AND PRODUCT DESCRIPTION Part Number: VACR1003VUB1000K00 V A C R 1 MODEL VACR050 VACR100 (3) VACR120 VACR130 VACR150 VACR180 VACR200 (3) VACR250 VACR300 VACR400 VACR500 0 MOUNTING 0= 160 x 40 x 20 160 x 20 x 40 1= 167 x 60 x 30 167 x 30 x 60 2= 217 x 60 x 30 217 x 30 x 60 3= 240 x 40 x 20 240 x 20 x 40 4= 267 x 60 x 30 267 x 30 x 60 5= 300 x 40 x 20 300 x 20 x 40 6= 337 x 60 x 30 337 x 30 x 60 V = Vertical H = Horizontal 0 3 V U B 1 0 0 0 K 0 0 MAX. PERMISSIBLE VOLTAGE PROTECTION VALUE TOLERANCE SPECIAL E = EN1000 (EN 1000 V DC) U = UL 1000 V V = UL 600 V A = IP20 B = IP65 C = IP54 (on request) 3 digit value 1 digit multiplier MULTIPLIER 8 = *10-2 9 = *10-1 0 = *100 1 = *101 2 = *102 3 = *103 K = ± 10.0 % 00 = Standard Two digits code for special parts, edited by marketing. Product Description: VACR1003 V UL 1000 V IP65 100R 10 % VACR1003 V UL 1000 V IP65 100R 10 % MODEL MOUNTING MAX. PERMISSIBLE VOLTAGE PROTECTION VALUE TOLERANCE Note (3) Special flat version on request. Revision: 08-May-14 Document Number: 21035 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VACR www.vishay.com Vishay Draloric DIMENSIONS in millimeters MODEL VACR0500 VACR1003 VACR1000 VACR1001 VACR1202 VACR1301 VACR1505 VACR1503 VACR1501 VACR1502 VACR1504 VACR1804 VACR1806 VACR2005 VACR2001 VACR2502 VACR2506 VACR3002 VACR3004 VACR4004 VACR4006 VACR5006 MOUNTING b1 h1 l1 (1) l2 H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H V 40 20 40 20 40 20 60 30 60 30 60 30 40 20 40 20 60 30 60 30 60 30 60 30 60 30 40 20 60 30 60 30 60 30 60 30 60 30 60 30 60 30 60 30 20 40 20 40 20 40 30 60 30 60 30 60 20 40 20 40 30 60 30 60 30 60 30 60 30 60 20 40 30 60 30 60 30 60 30 60 30 60 30 60 30 60 30 60 160 160 240 240 160 160 167 167 217 217 167 167 300 300 240 240 167 167 217 217 267 267 267 267 337 337 300 300 167 167 217 217 337 337 217 217 287 267 267 267 337 337 337 337 145 145 225 225 145 145 150 150 200 200 150 150 285 285 225 225 150 150 200 200 250 250 250 250 320 320 285 285 150 150 200 200 320 320 200 200 250 250 250 250 320 320 320 320 MASS (kg) 0.26 0.26 0.7 0.5 0.43 0.9 0.55 0.7 0.7 0.9 1.1 Notes • VACR100 and VACR200 as special flat version on request. (1) Mounting note: The length l1 increases at 0.85 mm/100 mm while heating (mounting with fixed and movable bearing). Revision: 08-May-14 Document Number: 21035 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VACR www.vishay.com Vishay Draloric RATED POWER IN % DERATING 120 100 80 60 40 20 0 - 20 0 20 40 60 80 100 120 140 160 180 200 AMBIENT TEMPERATURE IN °C TEMPERATURE 180 MAX. PERMISSIBLE OPERATING VOLTAGE V UL 600 V/UL 1000 V 40 x 20 100 to 200 250 EN 1000 V DC 40 x 20 200 to 500 360 EN 1000 V DC 60 x 30 150 to 400 340 UL 600 V/UL 1000 V 60 x 30 130 to 250 230 EN 1000 V DC 60 x 30 100 to 180 210 UL 600 V/UL 1000 V 60 x 30 POWER RATING W SURFACE TEMPERATURE at T40 °C 50 to 100 Revision: 08-May-14 SIZE mm Document Number: 21035 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000