V23990 P545 x3x D3 19

V23990-P545-*3*-PM
preliminary datasheet
Output Inverter Application
flowPIM 0
600V/20A
General conditions
3phase SPWM
VGEon = 15 V
VGEoff =
0V
Rgon = 16 Ω
Rgoff =
8Ω
IGBT
Figure 1
FWD
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
Typical average static loss as a function of output current
Ploss = f(Iout)
30
Ploss (W)
Ploss (W)
40
Mi*cosf i= -1
25
Mi*cosfi = 1
30
20
15
20
10
10
5
Mi*cosfi = 1
Mi*cosfi = -1
0
0
5
At
Tj =
10
125
15
20
25
30
0
I out
0
(A) 35
At
Tj =
°C
Mi*cosφ from -1 to 1 in steps of 0,2
125
10
15
20
25
30
I out (A)
35
°C
Mi*cosφ from -1 to 1 in steps of 0,2
IGBT
Figure 3
Typical average switching loss
as a function of output current
FWD
Figure 4
Typical average switching loss
as a function of output current
Ploss = f(Iout)
15
Ploss (W)
Ploss (W)
5
Ploss = f(Iout)
4
12
fsw = 16kHz
3
fsw = 16kHz
9
2
6
1
3
fsw = 2kHz
fsw = 2kHz
0
0
0
5
10
15
20
At
Tj =
125
DC link =
fsw from
320
V
2 kHz to 16 kHz in steps of factor 2
copyright by Vincotech
25
30 I (A)
out
0
35
°C
1
5
10
15
20
At
Tj =
125
DC link =
fsw from
320
V
2 kHz to 16 kHz in steps of factor 2
25
30
I out (A)
35
°C
Revision: 3
V23990-P545-*3*-PM
preliminary datasheet
Output Inverter Application
flowPIM 0
Phase
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
600V/20A
Phase
Figure 6
Typical available 50Hz output current
as a function of switching frequency
Iout = f(Mi*cos φ)
30
Iout = f(fsw)
30
Iout (A)
Iout (A)
Th = 60°C
Th = 60°C
Th = 100°C
25
25
20
20
15
15
10
10
5
5
0
Th = 100°C
0
-1,0
-0,5
0,0
0,5
1,0
1
Mi*cos φ
At
Tj =
125
At
Tj =
DC link =
fsw =
Th from
320
V
4
kHz
60 °C to 100 °C in steps of 5 °C
°C
10
125
fsw (kHz)
100
°C
DC link = 320
V
Mi*cos φ = 0,8
Th from
60 °C to 100 °C in steps of 5 °C
Phase
Figure 7
Typical available 0Hz output current as a function
Ioutpeak = f(fsw)
of switching frequency
-1,00
-0,60
27,0-30,0
Iout (Apeak)
Iout (A)
30
Mi*cosfi
-0,80
Phase
Figure 8
Typical available 50Hz output current as a function of
Iout = f(fsw, Mi*cos φ)
Mi*cos φ and switching frequency
Th = 60°C
25
-0,40
20
-0,20
24,0-27,0
0,00
15
21,0-24,0
0,20
Th = 100°C
10
0,40
18,0-21,0
0,60
15,0-18,0
5
0,80
1,00
1
2
4
8
16
32
0
64
1
fsw (kHz)
10
At
Tj =
125
°C
At
Tj =
125
DC link =
Th =
320
80
V
°C
DC link =
Th from
320
V
60 °C to 100 °C in steps of 5 °C
Mi =
0
copyright by Vincotech
2
fsw (kHz)
100
°C
Revision: 3
V23990-P545-*3*-PM
preliminary datasheet
Output Inverter Application
flowPIM 0
Inverter
Figure 9
600V/20A
Inverter
Figure 10
Typical available peak output power as a function of
Pout=f(Th)
heatsink temperature
Typical efficiency as a function of output power
efficiency=f(Pout)
8
7
efficiency (%)
Pout (kW)
100
2kHz
6
99
2kHz
16kHz
5
4
98
3
16kHz
2
97
1
0
96
60
70
90
80
At
Tj =
125
DC link =
Mi =
cos φ=
fsw from
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Th ( o C)
100
0
°C
1
2
3
4
5
At
Tj =
125
DC link =
Mi =
cos φ=
fsw from
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
6
7
8
P out (kW)
9
°C
Inverter
Figure 11
Overload (%)
Typical available overload factor as a function of
Ppeak / Pnom=f(Pnom,fsw)
motor power and switching frequency
400
350
300
250
200
Switching frequency (kHz)
150
Motor nominal power (HP/kW)
100
2,00 / 1,47
3,00 / 2,21
5,00 / 3,68
7,50 / 5,52
10,00 / 7,36
15,00 / 11,03
1
399
266
160
0
0
0
2
399
266
160
0
0
0
4
399
266
160
0
0
0
8
399
266
160
0
0
0
16
370
247
148
0
0
0
At
Tj =
125
°C
DC link =
Mi =
320
1
V
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
copyright by Vincotech
3
Revision: 3