V23990 P823 F10 P2 19

V23990-P823-F10-PM
preliminary datasheet
Output Inverter Application
flowPACK 1 3rd gen
600V/50A
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 8 Ω
Rgoff = 8 Ω
IGBT
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
70
Ploss (W)
80
Ploss (W)
FRED
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
Mi*cosfi = 1
70
60
Mi*cosf i= -1
60
50
50
40
40
30
30
20
20
10
10
Mi*cosfi = -1
0
At
Tj =
10
20
150
30
40
50
60
70
Iout (A)
0
80
10
At
Tj =
°C
Mi*cosfi from -1 to 1 in steps of 0,2
20
150
30
40
50
60
70
Iout (A)
80
°C
Mi*cosfi from -1 to 1 in steps of 0,2
IGBT
Figure 3
Typical average switching loss
as a function of output current
Ploss = f(Iout)
30,0
Ploss = f(Iout)
14,0
12,0
fsw = 16kHz
25,0
FRED
Figure 4
Typical average switching loss
as a function of output current
Ploss (W)
Ploss (W)
Mi*cosfi = 1
0
0
fsw = 16kHz
10,0
20,0
8,0
15,0
6,0
10,0
4,0
5,0
2,0
fsw = 2kHz
fsw = 2kHz
0,0
0,0
0
At
Tj =
10
20
150
30
40
50
60
70Iout (A)
0
80
At
Tj =
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
copyright by Vincotech
10
150
20
30
40
50
60
70
80
Iout (A)
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
1
Revision: 2
V23990-P823-F10-PM
preliminary datasheet
Output Inverter Application
flowPACK 1 3rd gen
Phase
Figure 5
Typical available 50Hz output current
as a function Mi*cosfi
Typical available 50Hz output current
as a function of switching frequency
Iout = f(Mi*cosfi)
Iout (A)
Iout (A)
Th = 60°C
Th = 60°C
70
60
60
50
50
Th = 100°C
40
30
30
20
20
10
10
0
At
Tj =
Iout = f(fsw)
80
70
-1,0
Phase
Figure 6
80
40
600V/50A
Th = 100°C
0
-0,8
-0,6
-0,4
150
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cosfi
1
At
Tj =
°C
DC link = 320
V
fsw =
4
kHz
Th from 60 °C to 100 °C in steps of 5 °C
10
150
fsw (kHz)
100
°C
DC link = 320
V
Mi*cosfi = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
Phase
Figure 7
Typical available 0Hz output current as a function
Ioutpeak = f(fsw)
of switching frequency
Iout (Apeak)
-1,00
-0,80
Iout (A)
Phase
Figure 8
Typical available 50Hz output current as a function of
Iout = f(fsw, Mi*cosfi)
Mi*cosfi and switching frequency
70
60
Th = 60°C
-0,60
68,0-74,0
50
-0,40
62,0-68,0
56,0-62,0
-0,20
44,0-50,0
0,00
38,0-44,0
32,0-38,0
40
Mi*cosfi
50,0-56,0
Th = 100°C
30
0,20
26,0-32,0
20,0-26,0
0,40
20
0,60
10
0,80
0
1,00
1
2
4
8
16
32
64
1
fsw
10
At
Tj =
150
°C
At
Tj =
DC link =
Th =
320
80
V
°C
DC link = 320
V
Th from 60 °C to 100 °C in steps of 5 °C
Mi =
copyright by Vincotech
2
150
fsw (kHz)
100
°C
0
Revision: 2
V23990-P823-F10-PM
preliminary datasheet
Output Inverter Application
flowPACK 1 3rd gen
Inverter
Figure 9
Typical efficiency as a function of output power
efficiency=f(Pout)
efficiency (%)
Pout (kW)
Inverter
Figure 10
Typical available peak output power as a function of
Pout=f(Th)
heatsink temperature
20,0
18,0
100,0
2kHz
16,0
600V/50A
99,0
2kHz
98,0
14,0
97,0
12,0
96,0
10,0
95,0
16kHz
16kHz
8,0
94,0
6,0
93,0
4,0
92,0
2,0
91,0
0,0
90,0
60
At
Tj =
65
70
150
75
80
85
90
95
100
Th ( o C)
0,0
At
Tj =
°C
DC link = 320
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
5,0
150
10,0
15,0
20,0
Pout (kW)
25,0
°C
DC link = 320
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Inverter
Figure 11
Overload (%)
Typical available overload factor as a function of
Ppeak / Pnom=f(Pnom,fsw)
motor power and switching frequency
400
350
300
250
200
Switching frequency (kHz)
150
Motor nominal power (HP/kW)
100
002 / 001
002 / 001
003 / 002
005 / 004
008 / 006
010 / 007
1
1120
840
560
336
224
168
2
1101
826
551
330
220
165
4
1064
798
532
319
213
160
8
993
745
497
298
199
149
16
866
649
433
260
173
130
At
Tj =
150
°C
DC link =
Mi =
320
1
V
cosfi =
0,8
fsw from 1 kHz to 16kHz in steps of factor 2
Th =
90
°C
Motor eff = 0,85
copyright by Vincotech
3
Revision: 2
V23990-P823-F10-PM
preliminary datasheet
PRODUCT STATUS DEFINITIONS
Datasheet Status
Target
Preliminary
Final
Product Status
Definition
Formative or In Design
This datasheet contains the design specifications for
product development. Specifications may change in any
manner without notice. The data contained is exclusively
intended for technically trained staff.
First Production
This datasheet contains preliminary data, and
supplementary data may be published at a later date.
Vincotech reserves the right to make changes at any time
without notice in order to improve design. The data
contained is exclusively intended for technically trained
staff.
Full Production
This datasheet contains final specifications. Vincotech
reserves the right to make changes at any time without
notice in order to improve design. The data contained is
exclusively intended for technically trained staff.
DISCLAIMER
The information given in this datasheet describes the type of component and does not represent assured characteristics. For tested
values please contact Vincotech.Vincotech reserves the right to make changes without further notice to any products herein to improve
reliability, function or design. Vincotech does not assume any liability arising out of the application or use of any product or circuit
described herein; neither does it convey any license under its patent rights, nor the rights of others.
LIFE SUPPORT POLICY
Vincotech products are not authorised for use as critical components in life support devices or systems without the express written
approval of Vincotech.
As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or
sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labelling can be
reasonably expected to result in significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to
cause the failure of the life support device or system, or to affect its safety or effectiveness.
copyright by Vincotech
4
Revision: 2