V23990-P820-F10-PM preliminary datasheet Output Inverter Application flowPACK 1 3rd gen 1200V/75A General conditions 3phase SPWM VGEon = 15 V VGEoff = -15 V Rgon = 4 Ω Rgoff = 4 Ω IGBT Figure 1 Typical average static loss as a function of output current Ploss = f(Iout) 200 120 Ploss (W) Ploss (W) FRED Figure 2 Typical average static loss as a function of output current Ploss = f(Iout) 180 Mi*cosf i= -1 100 Mi*cosfi = 1 160 140 80 120 60 100 80 40 60 40 20 20 Mi*cosfi = -1 Mi*cosfi = 1 0 0 0 20 40 60 80 100 120 0 140 20 40 60 80 100 Iout (A) At Tj = 150 At Tj = °C Mi*cosfi from -1 to 1 in steps of 0.2 140 °C Mi*cosfi from -1 to 1 in steps of 0.2 IGBT Figure 3 Typical average switching loss as a function of output current FRED Figure 4 Typical average switching loss as a function of output current Ploss = f(Iout) Ploss (W) Ploss (W) 150 120 Iout (A) 200,0 180,0 fsw = 16kHz Ploss = f(Iout) 60,0 fsw = 16kHz 50,0 160,0 140,0 40,0 120,0 30,0 100,0 80,0 20,0 60,0 40,0 10,0 20,0 fsw = 2kHz fsw = 2kHz 0,0 0,0 0 At Tj = 20 150 40 60 80 100 0 120 Iout (A) 140 At Tj = °C DC link = 600 V fsw from 2 kHz to 16 kHz in steps of factor 2 copyright by Vincotech 20 150 40 60 80 100 120 Iout (A) 140 °C DC link = 600 V fsw from 2 kHz to 16 kHz in steps of factor 2 1 Revision: 2 V23990-P820-F10-PM preliminary datasheet Output Inverter Application flowPACK 1 3rd gen Phase Figure 5 Typical available 50Hz output current as a function Mi*cosfi 1200V/75A Phase Figure 6 Typical available 50Hz output current as a function of switching frequency Iout = f(Mi*cosfi) Iout (A) Iout (A) 120 100 Iout = f(fsw) 120 100 Th = 60°C Th = 60°C 80 80 60 60 Th = 100°C Th = 100°C 40 40 20 20 0 -1,0 At Tj = 0 -0,8 -0,6 -0,4 150 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 Mi*cosfi 1 At Tj = °C DC link = 600 V fsw = 4 kHz Th from 60 °C to 100 °C in steps of 5 °C 10 150 fsw (kHz) 100 °C DC link = 600 V Mi*cosfi = 0,8 Th from 60 °C to 100 °C in steps of 5 °C Phase Figure 7 Typical available 0Hz output current as a function Ioutpeak = f(fsw) of switching frequency Iout (Apeak) -1,00 -0,80 Iout (A) -0,60 90,0-100,0 90 80 Th = 60°C 70 -0,40 60 80,0-90,0 70,0-80,0 Phase Figure 8 Typical available 50Hz output current as a function of Iout = f(fsw, Mi*cosfi) Mi*cosfi and switching frequency -0,20 50,0-60,0 0,00 40,0-50,0 30,0-40,0 50 Mi*cosfi 60,0-70,0 Th = 100°C 40 0,20 20,0-30,0 30 10,0-20,0 0,40 20 0,60 1 2 4 8 16 fsw 32 0,80 10 1,00 0 64 1 10 At Tj = 150 °C At Tj = DC link = Th = 600 80 V °C DC link = 600 V Th from 60 °C to 100 °C in steps of 5 °C Mi = copyright by Vincotech 2 150 fsw (kHz) 100 °C 0 Revision: 2 V23990-P820-F10-PM preliminary datasheet Output Inverter Application flowPACK 1 3rd gen Inverter Figure 9 Inverter Figure 10 Typical efficiency as a function of output power efficiency=f(Pout) efficiency (%) Typical available peak output power as a function of Pout=f(Th) heatsink temperature Pout (kW) 1200V/75A 50,0 45,0 100,0 40,0 99,0 2kHz 98,0 2kHz 35,0 97,0 30,0 96,0 25,0 95,0 20,0 94,0 15,0 16kHz 93,0 16kHz 10,0 92,0 5,0 91,0 0,0 90,0 60 At Tj = 65 70 150 75 80 85 90 95 100 Th ( o C) 0,0 At Tj = °C DC link = 600 V Mi = 1 cosfi = 0,80 fsw from 2 kHz to 16 kHz in steps of factor 2 10,0 150 20,0 30,0 40,0 50,0 60,0 70,0 Pout (kW) °C DC link = 600 V Mi = 1 cosfi = 0,80 fsw from 2 kHz to 16 kHz in steps of factor 2 Inverter Figure 11 Overload (%) Typical available overload factor as a function of Ppeak / Pnom=f(Pnom,fsw) motor power and switching frequency 400 350 300 250 200 Switching frequency (kHz) 150 Motor nominal power (HP/kW) 100 005 / 004 008 / 006 010 / 007 015 / 011 020 / 015 025 / 018 1 785 523 393 262 196 157 2 741 494 371 247 185 148 4 662 441 331 221 165 132 8 533 355 267 178 133 0 16 364 243 182 121 0 0 At Tj = 150 °C DC link = Mi = 600 1 V cosfi = 0,8 fsw from 1 kHz to 16kHz in steps of factor 2 Th = 90 °C Motor eff = 0,85 copyright by Vincotech 3 Revision: 2 V23990-P820-F10-PM preliminary datasheet PRODUCT STATUS DEFINITIONS Datasheet Status Target Preliminary Final Product Status Definition Formative or In Design This datasheet contains the design specifications for product development. Specifications may change in any manner without notice. The data contained is exclusively intended for technically trained staff. First Production This datasheet contains preliminary data, and supplementary data may be published at a later date. Vincotech reserves the right to make changes at any time without notice in order to improve design. The data contained is exclusively intended for technically trained staff. Full Production This datasheet contains final specifications. Vincotech reserves the right to make changes at any time without notice in order to improve design. The data contained is exclusively intended for technically trained staff. DISCLAIMER The information given in this datasheet describes the type of component and does not represent assured characteristics. For tested values please contact Vincotech.Vincotech reserves the right to make changes without further notice to any products herein to improve reliability, function or design. Vincotech does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights, nor the rights of others. LIFE SUPPORT POLICY Vincotech products are not authorised for use as critical components in life support devices or systems without the express written approval of Vincotech. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labelling can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. copyright by Vincotech 4 Revision: 2