Datasheet

UNISONIC TECHNOLOGIES CO., LTD
U74AUC1G08
CMOS IC
SINGLE 2-INPUT AND GATE

DESCRIPTION
The U74AUC1G08 is a 2-input AND gate which provides the
function Y= Α • Β or Y=A  B in positive logic.
This device has power-down protective circuit, preventing
device destruction when it is powered down.

FEATURES
* Operate from 0.8V to 2.7V
* Low power dissipation : ICC=10μA (Max.)
* ±8mA Output Driver : VCC=1.8V
* Ioff Supports partial-Power-Down Mode Operation

ORDERING INFORMATION
Ordering Number
U74AUC1G08G-AE5-R
U74AUC1G08G-AL5-R

Package
SOT-23-5
SOT-353
Packing
Tape Reel
Tape Reel
MARKING
www.unisonic.com.tw
Copyright © 2015 Unisonic Technologies Co., Ltd
1 of 5
QW-R126-015.B
U74AUC1G08
CMOS IC

PIN CONFIGURATION

FUNCTION TABLE (each gate)
INPUT
A
L
L
H
H

OUTPUT
Y
L
L
L
H
B
L
H
L
H
LOGIC DIAGRAM (positive logic)
Logic symbol
IEC logic symbol
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 5
QW-R126-015.B
U74AUC1G08
CMOS IC
ABSOLUTE MAXIMUM RATING
PARAMETER
Supply Voltage
Input Voltage
RATINGS
UNIT
-0.5 ~ +3.6
V
-0.5 ~ +3.6
V
Output in the high or low state
-0.5 ~ VCC +0.5
V
Output Voltage
VOUT
Output in the power-off state
-0.5 ~ +3.6
V
VCC or GND Current
ICC
±100
mA
Continuous Output Current
IOUT
VOUT=0 ~ VCC
±20
mA
Input Clamp Current
IIK
VIN<0
-50
mA
Output Clamp Current
IOK
VO>VCC or VOUT<0
-50
mA
Storage Temperature Range
TSTG
-65 ~ +150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

TEST CONDITIONS
RECOMMENDED OPERATING CONDITIONS
PARAMETER
Supply Voltage
Input Voltage
Output Voltage
Operating Temperature
Input Transition Rise or Fall
Rate

SYMBOL
VCC
VIN
SYMBOL
VCC
VIN
VOUT
TA
∆t/∆v
TEST CONDITIONS
Operating
High or low state
MIN
0.8
0
0
-40
TYP
MAX
2.7
3.6
VCC
85
20
10
UNIT
V
V
V
°C
ns/V
ns/V
TYP
MAX
±0.1
±0.1
0.3
0.4
0.45
0.6
±5
±10
UNIT
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
μA
μA
0.1
10
μA
VCC=0.8V ~ 1.95V
VCC=2.3V ~ 2.7V
STATIC CHARACTERISTICS (TA =25°C , unless otherwise specified)
PARAMETER
SYMBOL
High-level Input Voltage
VIH
Low-level Input Voltage
VIL
High-Level Output voltage
Low-Level Output voltage
Input Leakage Current
Power OFF Leakage Current
VOH
VOL
II(LEAK)
Ioff
Quiescent Supply Current
ICC
Input Capacitance
CI
TEST CONDITIONS
VCC=0.8V
VCC=1.1V ~ 1.95V
VCC=2.3V ~2.7V
VCC=0.8V
VCC=1.1V ~ 1.95V
VCC=2.3V ~2.7V
VCC=0.8 ~ 2.7V, IOH=-100μA
VCC=0.8V, IOH=-700μA
VCC=1.1V, IOH=-3mA
VCC=1.4VIOH=-5mA
VCC=1.65V, IOH=-8mA
VCC=2.3V, IOH=-9mA
VCC=0.8 ~ 2.7V, IOL=100μA
VCC=0.8V, IOL=700μA
VCC=1.1V, IOL=3mA
VCC=1.4V, IOL=5mA
VCC=1.65V, IOL=8mA
VCC=2.3V, IOL=9mA
VCC=0 ~ 2.7V, VIN=VCC or GND
VCC=0V, VIN or VOUT=2.7V
VCC=0.8V to 2.7V,
VIN=VCC or GND, IOUT=0
VCC=2.5V, VIN=VCC or GND
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
VCC
0.65×VCC
1.7
0
0.35×VCC
0.7
VCC-0.1
0.55
0.8
1
1.2
1.8
0.2
0.25
3
pF
3 of 5
QW-R126-015.B
U74AUC1G08

DYNAMIC CHARACTERISTICS (TA =25°C , unless otherwise specified)
PARAMETER
Propagation delay from
inputs (A or B) to output(Y)

CMOS IC
SYMBOL
tPLH / tPHL
TEST CONDITIONS
VCC=0.8V
VCC=1.2±0.1V
CL=15pF,
VCC=1.5±0.1V
RL=2KΩ
VCC=1.8±0.15V
VCC=2.5±0.2V
CL=30pF,
VCC=1.8±0.15V
RL=1KΩ
CL=30pF,
VCC=2.5±0.2V
RL=500Ω
MIN
0.9
0.6
0.4
0.2
0.7
TYP
4.7
MAX
1.1
1.4
UNIT
ns
ns
ns
ns
ns
ns
0.5
ns
OPERATING CHARACTERISTICS (f=10MHz, TA =25°C , unless otherwise specified)
PARAMETER
Power Dissipation
Capacitance
SYMBOL
CPD
TEST CONDITIONS
VCC=0.8V
VCC=1.2V
VCC=1.5V
VCC=1.8V
VCC=2.5V
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
TYP
15
15
15
15
19
MAX
UNIT
pF
pF
pF
pF
pF
4 of 5
QW-R126-015.B
U74AUC1G08

CMOS IC
TEST CIRCUIT AND WAVEFORMS
VCC
0.8V
1.2V±0.1V
1.5V±0.1V
1.8V±0.15V
2.5V±0.2V
1.8V±0.15V
2.5V±0.2V
CL
15pF
15pF
15pF
15pF
15pF
30pF
30pF
RL
2kΩ
2kΩ
2kΩ
2kΩ
2kΩ
1kΩ
500Ω
VM
VCC/2
VCC/2
VCC/2
VCC/2
VCC/2
VCC/2
VCC/2
Notes: 1. CL includes probe and jig capacitance.
2. All input pulses are supplied by generators having the following characteristics: PRR ≤10MHz, ZO = 50Ω.
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 5
QW-R126-015.B