Downloads for Single Secondary Chassis Mount Power Transformers (F-345X)

P OWER TRANSFORMER
Chassis Mount: Single Secondary
F-345X
Electrical Specifications (@25C)
1. Maximum Power: 24.0 VA
2. Primary:
Series: 230V 50/60 Hz
Parallel: 115V 50/60 Hz
3. Secondary: 24.0VCT @ 1.00 Amps
4. Voltage Regulation: 15 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-345X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
A
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
BLK/GRN
RED/BLK
YEL/BLK
BLK
Dimensions:
Units: In inches
A
B
C
D
1.937
3.312
2.00
2.812
C
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 1.30 lbs
Schematic:
BLK
GRN
YEL/BLK
RED/BLK
B
D
GRN/YEL
GRN
BLK/GRN
Primary:
Series: BLK to BLK/GRN, Jumper YEL/BLK to RED/BLK
Parallel: BLK to YEL/BLK, Jumper BLK to RED/BLK and YEL/BLK to BLK/GRN
Secondary: Green to Green
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
460 Harley Knox Blvd
Phone 951-277-0757
Perris, CA 95271
Publish Date: December 04, 2013
Fax 951-277-2757
GRN
GRN/YEL
GRN