Datasheet

D3D
Miniature Door Switch
A Switch with Crimp-type
Connectors Reduces
Wiring Work. 9 mm long
stroke (plunger model)
● Choose from plunger or lever as the actuator type.
D
3
D
● Crimp-type connector offers an easy wiring work
and efficiency.
● Snap-fit attachment for easy installation.
● Providing long stroke with its unique mechanism.
● Variety of color models available.
RoHS Compliant
Model Number Legend
1
D3D- @
2 @
3
@
Contact Specifications
Contact
1. Actuator
1: Plunger
2: Lever
*
Please refer to "●Using Micro Loads" in "Precautions" for more
information on the minimum applicable load.
Resistive load
125 VAC
1A
250 VAC
0.5 A
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Contact form
Housing
color
SPDT
SPST-NC
White
D3D-111
D3D-121
D3D-131
Black
D3D-113
D3D-123
D3D-133
White
D3D-211
D3D-221
D3D-231
Black
D3D-213
D3D-223
D3D-233
Contact Form
5 VDC 1 mA
Rated voltage
List of Models
Lever
Gold alloy
Ratings
3. Housing color
1: White
3: Black
Plunger
Crossbar
Material
Minimum applicable load
(reference value) *
2. Contact form
1: SPDT
2: SPST-NC
3: SPST-NO
Actuator
Specification
SPST-NO
Approved Safety Standards
UL (UL1054/CSA C22.2 No.55)
Model
Rated voltage
Item
D3D
Resistive load
125 VAC
1A
250 VAC
0.5 A
VDE (EN61058-1)
●SPDT
Rated voltage
NC
Model
D3D
125 VAC
1A
250 VAC
0.5 A
Testing conditions: 5E4 (50,000 operations) T55 (0°C to 55°C)
COM
NO
●SPST-NC
NC
COM
●SPST-NO
COM
NO
1
D3D
Miniature Door Switch
Characteristics
Permissible operating speed
Permissible
operating frequency
7.5 mm to 500 mm/s
Mechanical
120 operations/min
Electrical
20 operations/min
Insulation resistance
100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value)
D
3
D
Dielectric strength
Vibration resistance
*1
Shock resistance *1
Durability *2
100 mΩ max.
Between terminals of the
same polarity
1,000 VAC 50/60 Hz 1 min
Between current-carrying metal
parts and ground
1,500 VAC 50/60Hz 1 min
Between each terminals and
non-current-carrying metal parts
1,500 VAC 50/60Hz 1 min
Malfunction
10 to 55Hz, 1.5 mm double amplitude
Durability
490 m/s2 {approx. 49G} max.
Malfunction
300 m/s2 {approx. 30G} max.
Mechanical
300,000 operations min. (60 operations/min)
Electrical
50,000 operations min. (20 operations/min)
Degree of protection
IEC IP00
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
250
−30°C to +60°C (at ambient humidity 60% max.)
(with no icing or condensation)
Ambient operating temperature
85% max. (for +5 to +35°C)
Ambient operating humidity
Weight
Approx. 4g
Note. The given values are initial values.
*1. Close or open circuit of the contact is 1 ms max.
*2. For testing conditions, consult your OMRON sales
representative.
Mounting Holes (Unit: mm)
0
22.9 -0.1
ࠉࠉ
11.2+0.1
0
R1 MAX.
R Direction of switch insertion
t
t=0.8~1.5mm
Dimensions (Unit: mm) and Operating Characteristics
The illustrations are for models with white housing as a representative. The @ is replaced with the code for the housing color that you
need. See the "List of Models" for available combinations of models.
●Plunger Models
D3D-11@
D3D-12@
D3D-13@
8.1 dia.
6 dia. R3
25
11.4
13.5
A
Type
15
Operating
Characteristics
1.5
15.75±0.2
R0.5
OP2 OP1
6.5
2
Model
Operating Force
Total Travel Force
OF Max.
TTF Max.
Total Travel
TT
COM
NO
Operating Position OP
Min.
Operating
Characteristics
Model
10
11
●Lever Models
D3D-21@
D3D-22@
D3D-23@
25
2
6
(90°) A
15.7±0.5
5.5
D3D-12@
D3D-13@
2.0 N {204 gf}
3.5 N {357 gf}
OP1 (NC-OFF)
13 mm
13 mm
(NC-OFF)
OP2 (NO-ON)
12 mm
12 mm
(NO-ON)
11.4
9±0.5
R1
Type
15
1.5
OP2 OP1
3
2
15
10
11
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Operating Force
Total Travel Force
OF Max.
TTF Max.
Total Travel
TT
COM
Operating Position OP
Lever model
D3D-21@
D3D-22@
D3D-23@
2.0 N {204 gf}
2.5 N {245 gf}
9.7 mm (reference value)
NC
NO
2
D3D-11@
9.0 mm (reference value)
NC
15
Plunger model
Min.
OP1 (NC-OFF)
13 mm
OP2 (NO-ON)
11.5 mm
13 mm
(NC-OFF)
11.5 mm
(NO-ON)
D3D
Miniature Door Switch
Precautions
★Please refer to "Common Precautions" for correct use.
Correct Use
●Mounting
●Wiring
This product does not have a waterproof or drip-proof
construction. Ensure that water does not enter the interior of the
Switch.
In particular, do not use the Switch in locations where water may
be spilt or flow over the Switch. Doing so may result in
deterioration of the insulation.
Do not use the Switch with Connector mounted and weight load
applied to the Connector and lead wire, otherwise it may rattle or
may result in connection failure.
●Operating Stroke
●Using Micro Loads
D
Even when using the Switch within the operating range, if there 3
D
are inrush currents or surges, it may decrease the durability of the
Switch. If necessary, insert a contact protection circuit.
In order to ensure stable contact force for NO contacts, set the
total stroke at least 5 mm.
Connector
• The terminals connect to JST’s HL Connector.
Contact: SSF-21T-P1.4
Housing: HLP-03V
• OMRON does not sell the HL Connector.
• Contact JST Mfg. for more information on the connectors.
J.S.T. Manufacturing Co.,Ltd.
http://www.jst-mfg.com/index_e.php
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. B107-E1-03
0812(0207)(O)
3