Narrow Ring Terminal for Use in High Density Terminal Blocks

Narrow Ring Terminal for Use in
High-Density Barrier Terminal Blocks
APPLICATION NOTE
Applications:
Equipment that utilizes high-density terminal blocks such as
control panels, switch panels, power distribution panels.
Customer Concern:
A manufacturer of switch panels could not find a source of
ring terminals for connecting #8 AWG wire onto high-density,
space saving barrier terminal blocks with #8 size studs. The
barrier terminal block they were required to use was a new,
high-density barrier terminal block of European design, which
has a reduced width for each stud well to increase the number
of terminations per linear distance. The spacing required a
maximum width of 0.340" for each ring terminal.
Insulated Large Gauge Ring Terminals Designed
For Use in High-Density Barrier Terminal Blocks
Panduit Solution:
#8 AWG Insulated Narrow Ring Terminal
Panduit modified the standard #8 AWG ring terminal to fit
within the customer’s high-density barrier terminal block. The
area between the tongue and the barrel was also modified to
eliminate the possibility of arcing between adjacent installed
terminals on the barrier terminal block. The barrel dimensions
were left unchanged so that the same crimp tools could provide
the same crimping characteristics. Panduit also verified that
the narrow ring terminals in the customer’s high-density barrier
terminal block passed static heating tests required by UL 486.
Application Considerations:
Static heating must be tested because of the reduced space
between terminals. Static heating is described as the amount of
temperature rise that occurs when the terminals are operating
for thirty minutes at maximum operating current. Also, minimum
spacing for terminal blocks should not violate UL 1059 Terminal
Blocks, in UL approved applications.
w w w . pa n d u it.c o m
Comparison of Standard Tongue Ring Terminal
on Left with Narrow Tongue Ring Terminal
on Right
Narrow Ring Terminal for Use in High-Density Barrier Terminal Blocks
H Dia
Terminal
W
.290 ± .01
.315 ± .01
A
C Rad
M
Brazed
Seam
Housing
.280 (7.11)
Max. Wire
Insul. Dia.
Part Number
Dimensions In. (mm)
Stud
Size
A±.03
W±.01
C±.02
M±.03
H±.01
PV8-8RN-Q
#8
1.48
(37.59)
0.36
(9.14)
0.43
(10.92)
1.30
(33.02)
0.17
(4.32)
PV8-8R-QY
#8
1.51
(38.35)
0.42
(10.67)
0.43
(10.92)
1.30
(33.02)
0.17
(4.32)
PV8-10R-QY
#10
1.53
(38.86)
0.47
(11.94)
0.43
(10.92)
1.30
(33.02)
0.20
(5.08)
PV8-14R-QY
1/4"
1.53
(38.86)
0.47
(11.94)
0.43
(10.92)
1.30
(33.02)
0.27
(6.86)
PV8-56R-QY
5/16"
1.64
(41.66)
0.59
(14.99)
0.51
(12.95)
1.35
(34.29)
0.33
(8.38)
PV8-38R-QY
3/8"
1.64
(41.66)
0.59
(14.99)
0.51
(12.95)
1.35
(34.29)
0.39
(9.91)
PV8-12R-XY
1/2"
1.74
(44.20)
0.82
(20.83)
0.51
(12.95)
1.33
(33.78)
0.52
(13.21)
Crimp Tool
CT-720 with
CD-720PV8-2
CT-2600 with
CD-2600-PV8
Notes:
1. UL 486 Listed for:
a. 600 V maximum voltage rating
b. 221°F (105°C) maximum temperature rating
c. #8 AWG stranded copper wire
2. Material:
a. Stamping – 0.040" (1.02) thick copper, tin-plated
b. Housing – Vinyl, red
4. Dimensions in brackets are in millimeters
5. Installation tool: CT-720 w/CD-720PV8-2, CT-2600 w/CD-2600-PV8
6. Wire strip length 3/8+1/32
7. Package qty: -Q or -QY = 25 pcs. and -XY = 10 pcs
8. Other quantities available: replace the -Q, -QY, or -XY at the end of the part number to -T or -TY for a quantity or 200.
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
[email protected]
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
[email protected]
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
[email protected]
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
[email protected]
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
[email protected]
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
[email protected]
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: [email protected]
or by phone: 800.777.3300
©2015 Panduit Corp.
ALL RIGHTS RESERVED.
TMAN13--WW-ENG
replaces WW-TMAN03
12/2015