P OWER TRANS FOR MER Chassis Mount : International Series VPL25-1000 Electrical Specifications (@25C) 1. Maximum Power: 25.0VA 2. Input Voltage – Series: 230VAC @ 50/60Hz, Parallel: 115VAC@ 50/60Hz 1 2 3. Output Voltage – Series : 25.2V CT@ 0.99A, Parallel : 12.6V @ 1.98A 4. Voltage Regulation: 20% TYP @ full load to no load 5. Hipot: 3500VAC between primary to secondary and windings to core. 6. Recommended Fuse3: Series: Littelfuse p/n 313 1.25HXP, 1.25A 250V, slow blow, ¼ x 1 ¼ or, Cooper Bussmann p/n BK/MDL-1 ¼, 1.25A 250V, ¼ x 1 ¼ Parallel: Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or, Cooper Bussmann p/n BK/MDL-2 ½, 2.5A 250V, ¼ x 1 ¼ Dual winding construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements. Shrouds are provided over the connections of the leads to the windings on both primary and secondary coils. Devices are designed with a minimum of 6mm creepage distance between the primary and secondary and are manufactured with a Class B (130°C) insulation system. BRN BLU BLK WHT Construction: E A Agency Files: Dimensions: B Units: In inches A B C D E F 1.937 3.250 2.125 2.812 8.00 0.187 VIO RED GRY YEL UL File: E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3 cUL: File E65390, For Canadian Use (CSA 22.2, No.66.1-06 and No.66.3-06) TUV Certificate No.: R72103639, EN60950, Information Technology D Weight: 1.3 lbs. C F 4 Connections : Input: Series – BLK to BLU, Jumper WHT to BRN Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU Output: Series – RED to GRY, Jumper YEL to VIO Parallel – RED to GRY, Jumper RED to VIO and YEL to GRY RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. BLK RED WHT * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. BRN YEL VIO 1 Non-Inherently limited. Class 3. BLU GRY 2 Non-Inherently limited. Class 2 not wet, Class 3 wet. 3 Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation. Primary and secondary windings are designed to be connected in series or parallel. Winding are not intended to be used independently. 4 Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 SCHEMATIC Publish Date: December 4, 2013