Datasheet

UNISONIC TECHNOLOGIES CO., LTD
MGBR20S60C
Preliminary
DIODE
DUAL MOS GATED BARRIER
RECTIFIERS

DESCRIPTION
The UTC MGBR20S60C is a dual mos gated barrier
rectifiers, it uses UTC’s advanced technology to provide
customers with high current capability, low forward voltage and
high switching speed, etc.

FEATURES
* Super low forward voltage
* High switching speed
* High current capability


SYMBOL
ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
MGBR20S60CL-TA3-T
MGBR20S60CG-TA3-T
MGBR20S60CL-TF3-T
MGBR20S60CG-TF3-T
Note: Pin Assignment: A: Anode K: Common Cathode

Package
TO-220
TO-220F
Pin Assignment
1
2
3
A
K
A
A
K
A
Packing
Tube
Tube
MARKING
www.unisonic.com.tw
Copyright © 2016 Unisonic Technologies Co., Ltd
1 of 3
QW-R601-121.c
MGBR20S60C

Preliminary
DIODE
ABSOLUTE MAXIMUM RATINGS (TA=25°C unless otherwise specified)
PARAMETER
DC Blocking Voltage
Working Peak Reverse Voltage
Peak Repetitive Reverse Voltage
RATINGS
UNIT
60
V
60
V
60
V
Per Leg
10
A
Average Rectified Forward Current
IO
Total
20
A
Peak Forward Surge Current
IFSM
130
A
Operating Junction Temperature
TJ
-40 ~ +150
°C
Storage Temperature
TSTG
-40 ~ +150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

SYMBOL
VRM
VRWM
VRRM
THERMAL CHARACTERISTICS (PER LEG)
PARAMETER
Typical Thermal Resistance

SYMBOL
TO-220
TO-220F
θJC
RATINGS
2
4
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (PER LEG) (TA =25°C unless otherwise specified)
PARAMETER
Reverse Breakdown Voltage
SYMBOL
TEST CONDITIONS
V(BR)R
IR=0.60mA
IF=5A, TJ=25°C
IF=5A, TJ=125°C
Instantaneous Forward Voltage
VFM
IF=10A, TJ=25°C
IF=10A, TJ=125°C
VRM=60V, TJ=25°C
Leakage Current
IRM
VRM=60V, TJ=125°C
Note: Pulse Test: Pulse width ≤ 300µs, Duty cycle ≤ 2%.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
60
TYP MAX UNIT
V
0.42
V
0.38
V
0.54
V
0.49
V
500 μA
50
mA
2 of 3
QW-R601-121.c
MGBR20S60C
Preliminary
DIODE
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R601-121.c