WinQCM is a software package designed to control our QCM instruments, PC and to collect data. Mass
changes in the nanogram range can be measured accurately.
Main features
■Connection and simultaneously measurement the devices
One PC can be connected with max. 8 channels of devices (QCM922A, QCM934, QCA922 and QCA917)
■Data points
10 to 1,080,000(12.5 days or less of one sampling interval second)
■Graph display of measurement data
Resonance frequency, resonance resistance, temperature and voltage of analog inputs can be displayed in
the graph.
Setup Parameters
■Base Freq.
Enter a start frequency for frequency sweep.
■Gate Time / Avg. Time
Select the sampling interval of the QCM from the list.
■Sampling Time (Multiples of Gate Time)
Select the time interval at which the PC takes data.
■Number of Sampling
Input the data sampling frequency.
■Ext. Input
Select the voltage ranges for external analog inputs
from the list.
System Requirements
Item
Description
Machine supported
IBM® PC/AT® compatible
CPU
Memory
Intel® compatible CPU with 1 GHz or more
Microsoft® Windows® 8.1/8/7/Vista (each 32bits/64bits)
* For OSs of the 64-bit version, it operates in the 32-bit compatible mode
2GB or more
Free HDD Space
Free space of 1MB or more (except for .NET Framework and data save area)
Display
1024 × 768 or higher resolution, True Color (32 bits, highest) or higher
Disk Unit
CD-ROM drive for software installation
Others
Microsoft® .NET Framework 4.0 or higher needed to be installed, USB2.0 port
OS supported
PS-P600EA WinQCM Specification
Item
Compatible QCM
Communication I/F
Number of connection
channels
Resonance frequency
Resonance resistance
Admittance index
Functions
Main Unit Control
Sampling Interval
Sampling interval
Graphing Features
File reading
File retention
Others
Description
QCM922A
QCM934
QCM922
USB2.0
QCA917
GPIB
8 channels (max)
0.01 Hz
0.01 Ω
0.1 Hz
0.1 Ω
No unit
Measurement conditions settings, data collection, graphical representation,
file retention/reading, data analysis, etc.
Measurement start/pause/stop, measurement condition settings, etc.
It is possible to select a mean or momentary value for a gate time base.
Gate time
Sampling interval
0.01 sec (10 ms)
0.01/ 0.1/ 0.2/ 0.5 sec * only QCM922A
0.02 sec (20 ms)
0.02/ 0.1/ 0.2/ 0.5 sec * only QCM922A
0.1 sec (100 ms)
0.1/ 0.2/ 0.5/ 1 sec
1 sec
1/ 2/ 5/ 10 sec
10 sec
10/ 20/ 30/ 60 sec
10 to 1,080,000 (12.5 days or less of one sampling interval second)
· Data is graphically displayed in real time.
· Up to 4 graphs from a single file or a single graph from 4 different files can be displayed on
one screen.
· Scaling and scrolling graphs
· Hover box that displays the data values at the cursor position
· Data can be displayed in line or dot format
· Displays the amount of the change (Δ) from the arbitrary standard value
· Displays the calculated results for the amount of change (Δ) between two arbitrary set
points
Can read either comma delimited ASCII files from WinQCM and WinEchem or binary files
from WinEchem
CSV format text file
Copying the measured data and graphs to a clipboard, printing a graph, etc.
*Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation, the U.S.A., in
the U.S.A. and other countries.
*The other company or product names in the text are the trademark or registered trademark of each
company.
The specification is subject to change without notice. Please be forewarned.
SEIKO EG&G CO.,LTD.
Grande Bldgs., 2-26-9, Hatchobori,
Chuo-ku, Tokyo 104-0032, Japan
TEL:(+81)3-5543-3106
FAX:(+81)3-5542-3109
http://www.sii.co.jp/segg
July 2015 Rev. 1.0