Downloads for Isolation Power Transformers (N-76U)

P OWE R T RAN S FO R M E R
CHASSIS MOUNT : Isolation
N-76U
Electrical Specifications (@25°C)
1. Maximum Power:
2. Input Voltage:
3. Output Voltage:
5. Voltage Regulation:
100 VA
115V@50/60Hz
115V4. Full Secondary Load:
9% TYP @ full load to no load
0.86Amps RMS
Description:
The N-76U is power transformer for isolating equipment from direct connection to the
power line. This prevents electrical connection under normal or overload conditions
between the primary and secondary windings.
BL K
Safety:
BLK
These units are designed with 1500V isolation between winding to winding and
between winding and core. Materials and construction are rated for Class B (130°C)
insulation system.
Dimensions:
RED
RED
Unit: In inches
A
B
C
D
E
3.437
2.812
3.00
2.25
2.50
D
Weight: 4.0 Lbs.
Mounting Holes: 0.203 x 0.375”
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
C
Schematic:
BLK
RED
115V
115 V
50/60 HZ
0.87 A
BLK
RED
E
INPUT: BLK to BLK
OUTPUT: RED to RED
A
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
B
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571