Downloads for Autotransformer Power Transformers (N-6U)

P OWE R T RAN S FO R M E R
CHASSIS MOUNT : Autotransformer
N-6U
Electrical Specifications (@25°C)
1. Maximum Power:
200 VA
2. Input Voltage:
230 V, 50 / 60 Hz
3. Output Voltage:
115V + 5%
4. Full Secondary Load: 1.70 Amps RMS
Description:
The N-6U is part of the line of Auto-Transformers that are single winding
transformers in which the secondary coil is a fraction of the entire winding for
voltage step-down. This causes part of the power to be transferred
conductively through the windings, rather than all of the power being
transferred by induction.
RED
BLK
Safety:
These units are designed with 1500V isolation between the winding and the
core. Materials and construction are rated for Class B insulation system.
Dimensions:
WHT
Unit: In inches
A
B
C
D
E
3.375
2.812
2.812
2.250
2.250
B
C
Weight: 3.60 lbs
Mounting Holes: 0.203 x 0.375
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
Schematic:
RED
230 V
E
BLK
115 V
0V
WHT
For 230V input: Wht to Red
For 115 output: Wht to Blk
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
D
Publish Date: May 11, 2015
A