CLASS 2 TRANSFORMER F28-85-C2 Description: The F28-085-C2 is a single primary and dual secondary, split bobbin design which operates with an input of 115V. The output voltage will be either 28.0V with a center-tap under a 0.085A load with the secondaries wired in series, or 14.0V under a 0.17A load with the secondaries wired in parallel. The split bobbin design eliminates the need for costly electrostatic shielding. Electrical Specifications (@25C) 1. Maximum Power: 2.5VA 2. Primary: 115V 3. Secondary: Series: 28.0V CT@ 0.085A Parallel: 14.0V @ 0.17A 4. Voltage Regulation: 25% TYP @ full load to no load 5. Temperature Rise: 25C TYP 6. Hipot tested 100% at 2500 VRMS 7. Inherently Limited. No fusing required. W Construction: Three flange bobbin construction with primaries and secondaries wound side by side for low capacitive coupling. UL Class F Insulation System (155°C). E Agency File: UL: File E65390, UL 5085-3 (1585), Class 2 not wet / Class 3 wet Transformers cUL: File E65390, UL 5085-3 (1585) For Canadian Use (CSA 22.2, No.66.3-06) L H Dimensions: H W 1.187 1.125 Weight: 0.25 lbs Units in inches. L 1.375 A 0.250 B 0.250 C 1.200 D 0.041 E 0.020 F 0.234 4 1 D F Schematic: 5 1 115V 50/60Hz 4 6 7 A A 5 8 B 8 C RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2002/95/EC, known as the RoHS initiative. 1 As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2 and 5085-3, respectively. 4 0.06" DIAMETER HOLE Board Layout * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. www.TriadMagnetics.com 460 Harley Knox Blvd. Phone 951-277-0757 Perris, California 92571 Fax 951-277-2757 Publish Date: December 4, 2013