Description:
The F36-065-C2 is a single primary and dual secondary, split bobbin design
which operates with an input of 115V. The output voltage will be either 36.0V
with a center-tap under a 0.065A load with the secondaries wired in series, or
18.0V under a 0.13A load with the secondaries wired in parallel. The split bobbin
design eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 2.5VA
2. Primary:
115V, 50/60 Hz
3. Secondary: Series: 36.0V CT@ 0.065A
Parallel: 18.0V @ 0.13A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
7. Inherently Limited. No fusing required.
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155°C).
E
Agency File:
UL: File E65390, UL 5085-3 (1585), Class 3 Transformers
cUL: File E65390, UL 5085-3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
L
H
Dimensions:
H
W
1.187 1.125
Weight: 0.25 lbs
Units in inches.
L
1.375
A
0.250
B
0.250
C
1.200
D
0.041
E
0.020
F
0.234
4
1
D
F
Schematic:
5
A
1
115V
50/60Hz
4
A
5
6
7
8
B
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
1
4
0.06" DIAMETER
HOLE
Board Layout
Publish Date: December 4, 2013