BAT54WS Datasheet

BAT54WS
www.vishay.com
Vishay Semiconductors
Small Signal Schottky Diode
FEATURES
• These diodes feature very low turn-on voltage
and fast switching
• These devices are protected by a PN junction
guard ring against excessive voltage, such as
electrostatic discharges
MECHANICAL DATA
• AEC-Q101 qualified
Case: SOD-323
Weight: approx. 4.3 mg
Packaging codes/options:
18/10K per 13" reel (8 mm tape), 10K/box
08/3K per 7" reel (8 mm tape), 15K/box
• Base P/N-E3 - RoHS-compliant, commercial grade
• Base P/N-HE3 - RoHS-compliant, AEC-Q101 qualified
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
PARTS TABLE
PART
ORDERING CODE
INTERNAL
CONSTRUCTION
TYPE MARKING
REMARKS
Single diode
L4
Tape and reel
BAT54WS-E3-08 or BAT54WS-E3-18
BAT54WS
BAT54WS-HE3-08 or BAT54WS-HE3-18
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
Repetitive peak reverse voltage
SYMBOL
VALUE
UNIT
VRRM
30
V
IF
200
mA
IFRM
300
mA
IFSM
600
mA
Ptot
150
mW
SYMBOL
VALUE
UNIT
RthJA
650
K/W
Tj
125
°C
Storage temperature range
Tstg
- 65 to + 150
°C
Operating temperature range
Top
- 55 to + 125
°C
Forward continuous current
(1)
Repetitive peak forward current
Surge forward current
Power dissipation
(1)
(1)
tp < 1 s
(1)
Note
(1) Valid provided that electrodes are kept at ambient temperature
THERMAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Thermal resistance junction to ambient air
TEST CONDITION
(1)
Maximum junction temperature
Note
(1) Valid provided that electrodes are kept at ambient temperature
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Reverse breakdown voltage
Leakage current (1)
Forward voltage (1)
Diode capacitance
Reserve recovery time
TEST CONDITION
SYMBOL
MIN.
Tested with 100 μA pulses
V(BR)
30
VR = 25 V
TYP.
MAX.
UNIT
IR
2
μA
IF = 0.1 mA
VF
240
mV
IF = 1 mA
VF
320
mV
IF = 10 mA
VF
400
mV
IF = 30 mA
VF
500
mV
IF = 100 mA
VF
800
mV
VR = 1 V, f = 1 MHz
CD
10
pF
IF = 10 mA, IR = 10 mA,
iR = 1 mA, RL = 100 
trr
5
ns
V
Note
(1) Pulse test; t 300 μs,  < 2 %
p
Rev. 1.7, 25-Feb-13
Document Number: 85667
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
BAT54WS
www.vishay.com
Vishay Semiconductors
TYPICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
I F - Forward Current (mA)
1000
T j = 125 °C
100
- 40 °C
10
1
25 °C
0.1
0.01
0
0.2
18867
1.2
0.4 0.6 0.8
1
VF - Forward Voltage (V)
1.4
Fig. 1 - Typical Forward Current vs. Forward Voltage
vs. Various Temperatures
14
C D - Typical Capacitance (pF)
12
10
8
6
4
2
0
0
4
18868
12
16
20
24
8
VR - Reverse Voltage (V)
28
Fig. 2 - Typical Capacitance vs. Reverse Applied Voltage
1000
I R - Reverse Current (µA)
T j = 125 °C
100
100 °C
75 °C
10
50 °C
1
25 °C
0.1
0.01
0
18869
5
10
15
20
25
VR - Reverse Voltage (V)
30
Fig. 3 - Typical Reverse Current vs. Reverse Voltage
vs. Various Temperatures
Rev. 1.7, 25-Feb-13
Document Number: 85667
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
BAT54WS
www.vishay.com
Vishay Semiconductors
0.1 (0.004) max.
0° to 8
°
0.15 (0.006)
0.10 (0.004)
0.2 (0.008)
0.8 (0.031)
1.15 (0.045)
PACKAGE DIMENSIONS in millimeters (inches): SOD-323
0.40 (0.016)
0.25 (0.010)
1.95 (0.077)
1.60 (0.063)
2.50 (0.098)
1.1 (0.043)
2.85 (0.112)
1.5 (0.059)
0.40 (0.016)
0.20 (0.008)
Cathode bar
Foot print recommendation:
Document no.:S8-V-3910.02-001 (4)
Created - Date: 24.August.2004
Rev. 5 - Date: 23.Sept.2009
17443
Rev. 1.7, 25-Feb-13
1.6 (0.063)
0.6 (0.024)
0.6 (0.024)
0.6 (0.024)
Document Number: 85667
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000