ECV www.vishay.com Vishay Roederstein Aluminum Capacitors FEATURES • Load life: 2000 h at 105 °C • Miniature dimension • SMD style • Reflow soldering • Polarized aluminum electrolytic capacitors • Material categorization: For definitions of compliance please see www.vishay.com/doc?99912 QUICK REFERENCE DATA DESCRIPTION APPLICATIONS VALUE Nominal case size (Ø D x L in mm) • Industrial electronics, automotive telecommunication systems 4 x 5.3 to 12.5 x 13.5 Rated capacitance range, CR Capacitance tolerance 10 μF to 2200 μF • Smoothing and filtering ± 20 % Rated voltage range • Miniature power supply units, dc-to-dc converters 6.3 V to 50 V Category temperature range Load life - 40 °C to 105 °C PACKAGING 2000 h Based on sectional specification Climatic category IEC 60068 electronics, Supplied in blister tape. IEC 60384-4/EN130300 40/105/56 SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm) RATED VOLTAGE (V) CR (μF) 6.3 10 16 25 35 50 10 4 x 5.3 5 x 5.3 6.3 x 5.8 22 6.3 x 5.8 6.3 x 5.8 8 x 6.2 33 6.3 x 5.8 6.3 x 5.8 8 x 6.2 8 x 10 47 5 x 5.3 6.3 x 5.8 8 x 6.2 8 x 10 10 x 10 100 6.3 x 5.8 8 x 10 10 x 10 220 8 x 10 10 x 10 10 x 10 12.5 x 13.5 330 8 x 10 10 x 10 10 x 10 12.5 x 13.5 - 470 10 x 10 10 x 10 10 x 10 12.5 x 13.5 - 680 12.5 x 13.5 - - 1000 10 x 10 12.5 x 13.5 - - - 1500 10 x 10 12.5 x 13.5 - - - - 2200 12.5 x 13.5 - - - - - Revision: 18-Oct-12 Document Number: 25003 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ECV www.vishay.com Vishay Roederstein DIMENSIONS in millimeters CASE SIZE CODE D± L± A± B± C± E± R N P BB BC AD BM AE AF AG AH 4 ± 0.5 5 ± 0.5 6.3 ± 0.5 6.3 ± 0.5 8 ± 0.5 8 ± 0.5 10 ± 0.5 12.5 ± 0.5 5.3 ± 0.2 5.3 ± 0.2 5.8 ± 0.3 7.7 ± 0.4 6.2 ± 0.4 10 ± 0.5 10 ± 0.5 13.5 ± 0.5 1.9 ± 0.2 2.3 ± 0.2 2.4 ± 0.2 2.4 ± 0.2 3.3 ± 0.2 2.9 ± 0.2 3.2 ± 0.2 4.6 ± 0.2 4.3 ± 0.2 5.3 ± 0.2 6.6 ± 0.2 6.6 ± 0.2 8.3 ± 0.2 8.3 ± 0.2 10.3 ± 0.2 12.8 ± 0.2 4.3 ± 0.2 5.3 ± 0.2 6.6 ± 0.2 6.6 ± 0.2 8.3 ± 0.2 8.3 ± 0.2 10.3 ± 0.2 12.8 ± 0.2 1.0 ± 0.2 1.4 ± 0.2 2.2 ± 0.2 2.2 ± 0.2 2.3 ± 0.2 3.1 ± 0.2 4.5 ± 0.2 4.5 ± 0.2 0.5 to 0.8 0.5 to 0.8 0.5 to 0.8 0.5 to 0.8 0.5 to 0.8 0.8 to 1.1 0.8 to 1.1 1.1 to 1.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Capacitance N max. Plastic plateform C±α + Positive P max. A±α E±α A±α Voltage B±α Lot no. ØD±α 22 A 50 + L±α RESR IR - Negative ORDERING EXAMPLE ELECTRICAL DATA SYMBOL UR CR tan R ECV 220 μF/35 V, ± 20 %, size 10 mm x 10 mm DESCRIPTION Ordering code: MALSECV00AG322FARK Rated voltage Rated capacitance at 120 Hz Max. dissipation factor at 120 Hz Max. equivalent series resistance at 120 Hz Rated alternating current at 120 Hz and upper category temperature For Standard Packaging Quantity (SPQ) and Minimum Order Quantity (MOQ) please refer to our price list or contact customer service. Note • Unless otherwise specified, all electrical values apply at Tamb = 20 °C, P = 86 kPa to 106 kPa, RH = 45 % to 75 %. ELECTRICAL DATA AND ORDERING INFORMATION UR (V) 6.3 10 16 CR 120 Hz (μF) DIMENSIONS DxL (mm) tan 120 Hz RESR 120 Hz/20 °C () IR 120 Hz/105 °C (mA) WEIGHT (g) CATALOG NUMBER 47 330 1500 2200 100 220 470 1000 1500 10 33 47 220 330 470 1000 5 x 5.3 8 x 10 10 x 10 12.5 x 13.5 6.3 x 5.8 8 x 10 10 x 10 10 x 10 12.5 x 13.5 4 x 5.3 6.3 x 5.8 6.3 x 5.8 10 x 10 10 x 10 10 x 10 12.5 x 13.5 0.22 0.28 0.28 0.28 0.19 0.24 0.24 0.24 0.24 0.16 0.16 0.16 0.20 0.20 0.20 0.20 6.21 1.13 0.25 0.17 2.52 1.45 0.68 0.32 0.21 21.22 6.43 4.52 1.21 0.80 0.56 0.27 36 288 560 730 60 173 351 550 650 17 40 50 330 441 489 600 0.17 1.00 1.21 2.00 0.30 1.00 1.21 1.21 2.00 0.12 0.30 0.30 1.21 1.21 1.21 2.00 MALSECV00BC247BARK MALSECV00AF333BARK MALSECV00AG415BARK MALSECV00AH422BARK MALSECV00AD310CARK MALSECV00AF322CARK MALSECV00AG347CARK MALSECV00AG410CARK MALSECV00AH415CARK MALSECV00BB210DARK MALSECV00AD233DARK MALSECV00AD247DARK MALSECV00AG322DARK MALSECV00AG333DARK MALSECV00AG347DARK MALSECV00AH410DARK Revision: 18-Oct-12 Document Number: 25003 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ECV www.vishay.com Vishay Roederstein ELECTRICAL DATA AND ORDERING INFORMATION UR (V) 25 35 50 DIMENSIONS DxL (mm) 6.3 x 5.8 6.3 x 5.8 8 x 6.2 8 x 10 10 x 10 10 x 10 12.5 x 13.5 5 x 5.3 6.3 x 5.8 8 x 6.2 8 x 10 10 x 10 12.5 x 13.5 12.5 x 13.5 6.3 x 5.8 8 x 6.2 8 x 10 10 x 10 10 x 10 12.5 x 13.5 CR 120 Hz (μF) 22 33 47 100 330 470 680 10 22 33 47 220 330 470 10 22 33 47 100 220 tan 120 Hz 0.14 0.14 0.16 0.16 0.16 0.16 0.16 0.12 0.12 0.13 0.13 0.13 0.13 0.13 0.10 0.12 0.12 0.12 0.12 0.12 RESR 120 Hz/20 °C () 8.44 5.63 4.52 2.12 0.64 0.45 0.31 15.92 7.23 5.22 3.67 0.78 0.52 0.37 13.26 7.23 4.82 3.39 1.59 0.72 IR 120 Hz/105 °C (mA) 38 48 79 181 372 450 500 24 42 76 124 450 500 600 30 67 133 180 310 480 WEIGHT (g) CATALOG NUMBER 0.30 0.30 0.55 1.00 1.21 1.21 2.00 0.17 0.30 0.55 1.00 1.21 2.00 2.00 0.30 0.55 1.00 1.21 1.21 2.00 MALSECV00AD222EARK MALSECV00AD233EARK MALSECV00AE247EARK MALSECV00AF310EARK MALSECV00AG333EARK MALSECV00AG347EARK MALSECV00AH368EARK MALSECV00BC210FARK MALSECV00AD222FARK MALSECV00AE233FARK MALSECV00AF247FARK MALSECV00AG322FARK MALSECV00AH333FARK MALSECV00AH347FARK MALSECV00AD210HARK MALSECV00AE222HARK MALSECV00AF233HARK MALSECV00AG247HARK MALSECV00AG310HARK MALSECV00AH322HARK REFLOW SOLDERING CONDITIONS FOR SMD ALUMINUM ELECTROLYTIC CAPACITORS tP TP Critical Zone TL to TP Temperature Ramp-up TL tL Ts max. Ts min. Ramp-down ts Preheat t 25 °C to Peak Time PROFILE FEATURE Average ramp-up rate (TL to TP) Preheat Temperature min. (Ts min.) Temperature max. (Ts max.) Time (Ts min. to Ts max.) Ts max. to TL Ramp-up rate Time maintained above temperature (TL) Time (tL) Peak/classification temperature (TP) Time within 5 °C of actual peak temperature (TP) Ramp-down rate Time 25 °C to peak temperature Revision: 18-Oct-12 Ø 4 TO Ø 10 3 °C/s max. 150 °C 200 °C 60 s to 150 s 3 °C/s max. 217 °C 60 s to 90 s 250 °C 10 s max. 3 °C/s max. 8 min max. SOLDERING CONDITION Ø 12.5 3 °C/s max. Ø 16 150 °C 200 °C 40 s to 120 s 40 s to 100 s 3 °C/s max. 217 °C 40 s to 60 s 240 °C 230 °C 10 s max. 3 °C/s max. 8 min max. Document Number: 25003 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ECV www.vishay.com Vishay Roederstein RESISTANCE TO SOLDERING HEAT Leakage current Less than specified value Capacitance value Within ± 10 % of initial value tan Less than specified value LOW TEMPERATURE BEHAVIOR (at 120 Hz) IMPEDANCE RATIO (Z) T2/(Z) T1 RATED VOLTAGE (V) T2/T1 6.3 10 16 25 35 50 - 25 °C/+ 20 °C 3 3 2 2 2 2 - 40 °C/+ 20 °C 8 5 4 3 3 3 ADDITIONAL ELECTRICAL DATA PARAMETER CONDITIONS VALUE Current Leakage current (test conditions: UR, 20 °C) After 2 min at UR IL2 0.01 x CR x UR or 3 μA for UR 100 V (whichever is greater) Resistance Equivalent series resistance (ESR) Calculated from tan max. ESR = tan /2 f CR MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY FREQUENCY (Hz) IR MULTIPLIER FOR UR 100 V 50 0.70 120 1.00 300 1.17 1000 1.36 10 000 1.50 TEST PROCEDURES AND REQUIREMENTS PROCEDURE (quick reference) TEST Load life Shelf life Tamb = 105 °C C/C: ± 20 % of initial value UR and IR applied IL spec. limit After 2000 h tan 2 x spec. limit No voltage applied C/C: ± 20 % of initial value After 1000 h After test: UR to be applied for 30 min 24 h to 48 h before measurement Revision: 18-Oct-12 REQUIREMENTS IL spec. limit tan 2 x spec. limit Document Number: 25003 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000