ABC0000C4

Electric Double Layer Capacitors (Gold Capacitor)
Stacked Coin Type
Series :
RG
Features
● Endurance
: +85 °C 2000 h
be discharged mA current
● RoHS compliant
● Can
Recommended applications
● Backup
● For
of data/RTC of base station, electronic meter, and industrial equipment
assist of rapid load change
Specifications
Category temp. range
Maximum operating voltage
Nominal capacitance
Characteristics at
low temperature
Endurance
Shelf life
–25 °C to +85 °C
3.6 V.DC
0.22 F
1.0 F, 1.5 F
Capacitance change ±30 % of initial measured value at +20 °C (at –25 °C)
Internal resistance < 5 times of initial measured value at +20 °C (at –25 °C)
After 2000 hours application of maximum operating voltage at +85 °C
Capacitance change ±30 % of initial measured value at 20 °C
100 Ω or less (0.22 F)
Internal resistance
40 Ω or less (1.0 F, 1.5 F)
After 2000 hours storage at +85 °C without load (voltage)
Capacitance change Capacitance change shall meet the specified limits for Endurance
Internal resistance Internal resistance shall meet the specified limits for Endurance
Dimensions in mm(not to scale)
RG series 0.22(F)
Terminal : V
11.5 max.
6.0 max.
3.0±0.5
0.2±0.05
5.0±0.8
1.0±0.1
–
5.0±0.5
1.0±0.1
0.2±0.05
3.0±0.5
20.0±0.5
0.8±0.05
(1.7)
f19.0±0.3
20.5 Max.
+
0.20±0.05
0.2±0.05
10.0±0.5
Sleeve
5.5±0.5
21.0 max.
4.0±0.3
11.5 max.
010.5 max.
f19.0±0.3
Terminal : H
3.5±0.3 6.5 max.
Sleeve
5.0 max.
10.5 max.
0.8±0.05
(1.7)
Terminal : H
5.0±0.3
Terminal : V
RG series 1.0, 1.5(F)
(Unit : mm)
Characteristics list
Maximum
operating
voltage
(V.DC)
3.6
0.22
0.176 to 0.396
< 50
1 or less
EECRG0V224( )
1.0
Min.
packaging
q'ty
(pcs)
200
1.0
0.8 to 1.8
< 20
20 or less
EECRG0V105( )
4.1
100
1.5
1.2 to 2.7
< 20
20 or less
EECRG0V155( )
4.2
100
Capacitance
(F)
Capacitance Internal resistance Recommended
tolerance (Initial specified value) discharge current
(F)
(Ω) at 1 kHz
(mA)
Parts number
Mass
(Reference value)
(g)
Do not use reflow soldering. (IR, Atmospherheating methods, etc.) Please refer to the page of “Application guidelines”.
( ) : Please use V or H to indicate terminal type.
The recommended discharge current is a reference value. Please design your equipment(circuit) in consideration of IR dorop.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02
Jan. 2016