Electric Double Layer Capacitors (Gold Capacitor)/ RG Stacked Coin Type Series: RG ■ Features ● Endurance: 85 °C 2000 h ● Can be discharged mA current ● RoHS directive compliant ■ Recommended Applications ● Backup of data/RTC of base station, electronic meter, and industrial equipment ● For assist of rapid load change ■ Specifications Series Category temp. range Maximum operating voltage Nominal capacitance Capacitance tolerance RG –25 °C to +85 °C 3.6 V DC 0.22 F 1.0 F –20 % to +80% Lower category temp. (–25 °C) Upper category temp. (+85 °C) Stability at low and high Capacitance change ±30 % of initial measured value at 20 °C ±30 % of initial measured value at 20 °C temperature Internal resistance <5 times of initial measured value at 20 °C < initial measured value at 20 °C After 2000 hours application of maximum operating voltage at +85 °C Endurance Capacitance change ±30 % of initial measured value at 20 °C ±30 % of initial measured value at 20 °C Internal resistance 100 액 or less 40 액 or less After 2000 hours storage at +85 °C without load (voltage) Shelf life Capacitance change Capacitance change shall meet the specified limits for Endurance Internal resistance Internal resistance shall meet the specified limits for Endurance ■ Dimensions in mm(not to scale) RG series 0.22(F) Terminal : V 11.5 max. – 6.0 max. 3.0±0.5 0.2±0.05 5.5±0.5 20.5±0.5 4.0±0.3 11.5 max. φ10.5 max. φ19.0±0.3 Terminal : H 5.0±0.8 1.0±0.1 Sleeve 5.0±0.5 + 0.20±0.05 φ19.0±0.3 20.0±0.5 3.5±0.3 6.0±0.5 Sleeve 5.0 max. 20.0±0.5 0.2±0.05 1.0±0.1 0.2±0.05 10.0±0.5 0.8±0.05 (1.7) 3.0±0.5 10.5 max. 0.8±0.05 (1.7) Terminal : H 5.0±0.3 Terminal : V RG series 1.0(F) ■ Standard Products Series RG Maximum operating voltage (V DC) 3.6 Capacitance Internal resistance Recommended (Initial specified value) discharge current Parts number (mA) Mass Min. packaging Q'ty (g) (pcs) (F) (액) at 1 kHz 0.22 <50 1 or less EECRG0V224() 1.0 200 1.0 <20 20 or less EECRG0V105() 4.1 100 Do not use reflow sp;dering.(IR, Atmospherheating methods, etc.) Please refer to P195 “Mounting Specifications”. ( ): Please use V or H to indicate terminal type. The recommended discharge current is a reference value. Please design your equipment(circuit) in consideration of IR dorop. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. – EE186 – 00 Dec. 2009