V23990 P708 F T1 19

V23990-P708-F-PM
target data sheet
flow 90PACK 1 1200V/ 15A
V23990-P708-F-01-14
Output inverter application
General conditions3 phase SPWM, Vgeon=
Vgeoff=
15 V
-15 V
Rgon=
Figure 1. Typical avarage static loss
as a function of output current
Ploss=f(Iout)
IGBT
Figure 2.
Rgoff=
64 Typical avarage static loss
as a function of output current
FRED
Ploss=f(Iout)
35
Ploss (W)
45
Ploss (W)
64 40
30
Mi*cosfi=1
Mi*cosfi=-1
35
25
30
20
25
20
15
15
10
10
5
5
Mi*cosfi=1
Mi*cosfi=-1
0
0
0
5
10
15
Conditions:
Tj=125°C
Modulation index * cosfi
parameter
Mi*cosfi from
in
20
25
-1,00 to
0,20 steps
0
30
35
Iout (A)
5
10
15
25
30
35
Iout (A)
Conditions:
Tj=125°C
Modulation index * cosfi
parameter
Mi*cosfi from -1,00 to
in 0,20 steps
1,00
Figure 4.
1,00
Typical avarage switching loss
as a function of output current
FRED
Ploss=f(Iout)
Ploss (W)
Figure 3. Typical avarage switching loss
as a function of output current
Ploss=f(Iout)
IGBT
Ploss (W)
20
16,0
50,0
45,0
fsw=16kHz
14,0
fsw=16kHz
40,0
12,0
35,0
10,0
30,0
8,0
25,0
20,0
6,0
15,0
4,0
10,0
2,0
5,0
fsw=2kHz
fsw=2kHz
0,0
0,0
0
5
Conditions:
Switching freq.
parameter
10
15
Tj=125°C
DC link=
fsw from
in
Copyright by Vincotech
20
25
0
30Iout (A) 35
5
10
Conditions:
600 V
2 kHz to
* 2 steps
16 kHz
Switching freq.
parameter
1
15
20
Tj=125°C
DC link=
fsw from
in
25
30
600 V
2 kHz to
* 2 steps
Iout (A)
35
16 kHz
Revision: 1
V23990-P708-F-PM
target data sheet
flow 90PACK 1 1200V/ 15A
V23990-P708-F-01-14
Output inverter application
General conditions3 phase SPWM, Vgeon=
Vgeoff=
15 V
-15 V
Rgon=
Figure 5. Typical available 50Hz output current
as a function of Mi*cosfi
Iout=f(Mi*cosfi)
Phase
Figure 6.
Iout (A)
Iout (A)
25
Th=60°C
64 Rgoff=
64 Typical available 50Hz output current
as a function of switching frequency
Phase
Iout=f(fsw)
25
20
20
15
15
Th=60°C
Th=100°C
10
10
5
5
0
-1,0
Th=100°C
0
-0,8
-0,6
-0,4
Conditions:
Heatsink temp.
parameter
-0,2
0,0
0,2
Tj=125°C
DC link=
fsw=
Th from
in
0,4
0,6
0,8
1,0
Mi*cosfi
1
10
Conditions:
600
4
60
5
V
kHz
°C to
100 °C
°C
steps
Heatsink temp.
parameter
Figure 7. Typical available 50Hz output current
as a function of Mi*cosfi and fsw
Iout=f(fsw,Mi*cosfi)
Phase
Figure 8.
Iout (Apeak)
-1
-0,8
Iout (A)
100
600 V
0,8
60 °C to 100 °C
5 °C
steps
Typical available 0Hz output current
as a function of switching frequency
Phase
Ioutpeak=f(fsw)
25
20
-0,6
Tj=125°C
DC link=
Mi*cosfi=
Th from
in
fsw (kHz)
Th=60°C
-0,4
19-22
-0,2
13-16
0
10-13
7-10
15
Mi*cosfi
16-19
0,2
10
4-7
Th=100°C
0,4
0,6
5
0,8
1
2
4
8
16
1
32
0
1
fsw
Conditions:
Tj=125°C
DC link=
Th=
Copyright by Vincotech
10
Conditions:
600 V
80 °C
Heatsink temp.
parameter
2
Tj=125°C
DC link=
Th from
in
fsw (kHz)
100
600 V
60 °C to 100 °C
5 °C
steps
Revision: 1
V23990-P708-F-PM
target data sheet
flow 90PACK 1 1200V/ 15A
V23990-P708-F-01-14
Output inverter application
General conditions3 phase SPWM, Vgeon=
Vgeoff=
15 V
-15 V
Rgon=
Rgoff=
64 Figure 10. Typical efficiency
as a function of output power
Inverter
efficiency (%)
Pout (kW)
Figure 9. Typical available electric
peak output power as a
function of heatsink temperature
Pout=f(Th)
Inverter
64 12,0
10,0
100,0
efficiency=f(Pout)
2kHz
99,0
2kHz
8,0
98,0
6,0
97,0
4,0
96,0
16kHz
16kHz
2,0
95,0
0,0
94,0
60
65
70
75
80
Tj=125°C
DC link=
Modulation index Mi=
cosfi=
Switching freq.
fsw from
parameter
in
85
90
95
100
Th ( o C)
0,0
Conditions:
2,0
4,0
6,0
8,0
10,0
12,0
14,0
16,0
Pout (kW)
Conditions:
600 V
1
0,80
2 kHz to
* 2 steps
Tj=125°C
DC link= 600 V
Modulation index Mi=
1
cosfi= 0,80
Switching freq.
fsw from
2 kHz to
parameter
in
* 2 steps
16 kHz
16 kHz
Figure 11. Typical available overload factor
as a function of motor power
and switching frequency
Overload (%)
Inverter
Ppeak/Pnom=f(Pnom,fsw)
Conditions:
Tj=125°C
DC link= 600 V
Modulation index Mi=
1
cosfi= 0,8
Switching freq.
fsw from
1 kHz to
parameter
in
* 2 steps
Heatsink temperature=
80 °C
Motor efficiency= 0,85
400
350
300
250
16 kHz
200
150
Switching frequency (kHz)
Motor nominal power (HP/kW)
100
1,00 / 0,74 1,50 / 1,10 2,00 / 1,47 3,00 / 2,21 5,00 / 3,68 7,50 / 5,52
10,00 /
7,36
1
1123
749
562
374
225
150
112
2
1123
749
562
374
225
150
112
4
1086
724
543
362
217
145
0
8
885
590
442
295
177
118
0
16
616
411
308
205
123
Copyright by Vincotech
3
Revision: 1